{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:26:54Z","timestamp":1787758014585,"version":"build-2784847793"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>An ideal CO monitor should be noninvasive, cost effective, reproducible, reliable during various physiological states. Limited literature is available regarding the noninvasive CO monitoring in open chest surgeries.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>The aim of this study was to compare the CO measurement by Regional Impedance Cardiography (RIC) and Thermodilution (TD) method in patients undergoing off pump coronary artery bypass graft surgery (OPCAB).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>We conducted a prospective observational comparative study of CO measurement by the noninvasive RIC method using the NICaS Hemodynamic Navigator system and the gold standard TD method using pulmonary artery catheter in patients undergoing OPCAB. A total of 150 data pair from the two CO monitoring techniques were taken from 15 patients between 40-70 years at various predefined time intervals of the surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and Methods:<\/jats:title>\n                    <jats:p>We have tried to find out the accuracy, precision and cost effectiveness of the newer RIC technique. Mean CO, bias and precision were compared for each pair i.e. TD-CO and RIC-CO as recommended by Bland and Altman. The Sensitivity and specificity of cutoff value to predict change in TD-CO was used to create a Receiver operating characteristic or ROC curve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Mean TD-CO values were around 4.52 \u00b1 1.09 L\/min, while mean RIC- CO values were around 4.77\u00b1 1.84 L\/min. The difference in CO change was found to be statistically not significant (p value 0.667). The bias was small (-0.25). The Bland Altman plot revealed a mean difference of -0.25 litres. The RIC method had a sensitivity of 55.56 % and specificity of 33.33 % in predicting 15% change in CO of TD method and the total diagnostic accuracy was 46.67%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>A fair correlation was found between the two techniques. The RIC method may be considered as a promising noninvasive, potentially low cost alternative to the TD technique of hemodynamic measurement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aca.aca_44_21","type":"journal-article","created":{"date-parts":[[2022,7,5]],"date-time":"2022-07-05T08:19:30Z","timestamp":1657009170000},"page":"335-342","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Comparative Study of Cardiac Output Measurement by Regional Impedance Cardiography and Thermodilution Method in Patients Undergoing off Pump Coronary Artery Bypass Graft Surgery"],"prefix":"10.4103","volume":"25","author":[{"given":"Amrita","family":"Guha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dheeraj","family":"Arora","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yatin","family":"Mehta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-14-20240901","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1007\/s00134-007-0938-y","article-title":"Assessment of stroke volume index with three different bioimpedance algorithms: Lack of agreement compared to thermodilution","volume":"34","author":"de Waal","year":"2008","journal-title":"Intensive Care Med"},{"key":"R2-14-20240901","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.ejheart.2005.06.006","article-title":"Non-invasive measurement of cardiac output by whole-body bio-impedance during dobutamine stress echocardiography: Clinical implications in patients with left ventricular dysfunction and ischaemia","volume":"8","author":"Leitman","year":"2006","journal-title":"Eur J Heart Fail"},{"key":"R3-14-20240901","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1093\/bja\/72.1.133","article-title":"Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and doppler ultrasound","volume":"72","author":"Castor","year":"1994","journal-title":"Br J Anaesth"},{"key":"R4-14-20240901","doi-asserted-by":"crossref","first-page":"104","DOI":"10.4103\/0971-9784.81564","article-title":"Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients","volume":"14","author":"Sharma","year":"2011","journal-title":"Ann Card Anaesth"},{"key":"R5-14-20240901","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1088\/0967-3334\/27\/9\/005","article-title":"Impedance cardiography revisited","volume":"27","author":"Cotter","year":"2006","journal-title":"Physiol Meas"},{"key":"R6-14-20240901","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ccell.2006.01.008","article-title":"Bioimpedance cardiography measurements of cardiac output and other cardiovascular parameters","volume":"18","author":"Albert","year":"2006","journal-title":"Crit Care Nurs Clin North Am"},{"key":"R7-14-20240901","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1253\/circj.70.1164","article-title":"Impedance cardiography for cardiac output estimation","volume":"70","author":"Paredes","year":"2006","journal-title":"Circ J"},{"key":"R8-14-20240901","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1053\/jcan.2002.29635","article-title":"Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery","volume":"16","author":"Sageman","year":"2002","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R9-14-20240901","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1097\/00003246-199910000-00023","article-title":"Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operation","volume":"27","author":"K\u00f6\u00f6bi","year":"1999","journal-title":"Crit Care Med"},{"key":"R10-14-20240901","doi-asserted-by":"crossref","first-page":"2028","DOI":"10.1378\/chest.123.6.2028","article-title":"Impedance cardiographya","volume":"123","author":"Van De Water","year":"2003","journal-title":"Chest"},{"key":"R11-14-20240901","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/S0003-4975(98)90016-9","article-title":"Comparison of bioimpedance and thermodilution methods for determining cardiac output: Experimental and clinical studies","volume":"45","author":"Spinale","year":"1988","journal-title":"Ann Thorac Surg"},{"key":"R12-14-20240901","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1097\/00003246-198611000-00004","article-title":"Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients","volume":"14","author":"Appel","year":"1986","journal-title":"Crit Care Med"},{"key":"R13-14-20240901","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1177\/153857449102500706","article-title":"Ideal measurement of cardiac output: Is impedance cardiography the answer?","volume":"25","author":"Franko","year":"1991","journal-title":"Vasc Surg"},{"key":"R14-14-20240901","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/BF00336214","article-title":"Validation of impedance cardiography measurements of cardiac output during limited exercise in heart transplant recipients","volume":"3","author":"Pepke-Zaba","year":"1990","journal-title":"Transplant International"},{"key":"R15-14-20240901","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1097\/00003246-200003000-00016","article-title":"Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization","volume":"28","author":"Barin","year":"2000","journal-title":"Crit Care Med"},{"key":"R16-14-20240901","doi-asserted-by":"crossref","first-page":"2383","DOI":"10.1253\/circj.CJ-13-0172","article-title":"Noninvasive and simple assessment of cardiac output and pulmonary vascular resistance with whole-body impedance cardiography is useful for monitoring patients with pulmonary hypertension","volume":"77","author":"Taniguchi","year":"2013","journal-title":"Circ J"},{"key":"R17-14-20240901","doi-asserted-by":"crossref","first-page":"19","DOI":"10.14712\/18059694.2019.141","article-title":"Thoracic electrical bioimpedance versus thermodilution in patients post open-heart surgery","volume":"42","author":"\u017d\u00e1\u010dek","year":"1999","journal-title":"Acta Medica (Hradec Kralove"},{"key":"R18-14-20240901","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s00408-011-9299-y","article-title":"Value of impedance cardiography in patients studied for pulmonary hypertension","volume":"189","author":"Tonelli","year":"2011","journal-title":"Lung"},{"key":"R19-14-20240901","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s10877-008-9119-y","article-title":"Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: Comparison with thermodilution method","volume":"22","author":"Gujjar","year":"2008","journal-title":"J Clin Monit Comput"},{"key":"R20-14-20240901","doi-asserted-by":"crossref","first-page":"123","DOI":"10.4236\/wjcs.2014.47019","article-title":"Comparison of cardiac output measurement by noninvasive method with electrical cardiometry and invasive method with thermodilution technique in patients undergoing coronary artery bypass grafting","volume":"04","author":"Rajput","year":"2014","journal-title":"World J Cardiovasc Surg"},{"key":"R21-14-20240901","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1053\/jcan.2001.26533","article-title":"Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: Evaluation of a second-generation bioimpedance device","volume":"15","author":"Spiess","year":"2001","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R22-14-20240901","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1097\/00003246-199808000-00035","article-title":"Determination of cardiac output during mechanical ventilation by electrical bioimpedance or thermodilution in patients with acute lung injury","volume":"26","author":"Genoni","year":"1998","journal-title":"Crit Care Med"},{"key":"R23-14-20240901","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1186\/cc7129","article-title":"Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies \u2013 with specific reference to the measurement of cardiac output","volume":"13","author":"Cecconi","year":"2009","journal-title":"Crit Care"},{"key":"R24-14-20240901","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1136\/hrt.79.5.437","article-title":"Comparison of impedance cardiography and dye dilution method for measuring cardiac output","volume":"79","author":"Spiering","year":"1998","journal-title":"Heart"},{"key":"R25-14-20240901","first-page":"467","article-title":"Impedance cardiography using the Sramek- Bernstein method: Accuracy and variability at rest and during exercise","volume":"34","author":"Thomas","year":"1992","journal-title":"Br J Clin Pharmacol"},{"key":"R26-14-20240901","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1111\/j.1749-6632.1970.tb17735.x","article-title":"Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system","volume":"170","author":"Kubicek","year":"1970","journal-title":"Ann N Y Acad Sci"},{"key":"R27-14-20240901","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1007\/BF00271054","article-title":"Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation","volume":"15","author":"Preiser","year":"1989","journal-title":"Intensive Care Med"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_44_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:01:55Z","timestamp":1787756515000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_44_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_44_21","relation":{},"ISSN":["0971-9784"],"issn-type":[{"value":"0971-9784","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7]]}}}