{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T01:22:14Z","timestamp":1792200134387,"version":"4.4.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>\n                      Severe preeclampsia can lead to various complications including increased intracranial pressure (ICP) which can be catastrophic but difficult to detect because of variable nonspecific symptoms. Ultrasonography has been used as noninvasive measure to monitor optic nerve sheath diameter (ONSD) as a marker of raised ICP. Effect of MgSO\n                      <jats:sub>4<\/jats:sub>\n                      on ICP can modify the management approach, need for additional monitoring, targeting hemodynamic goals, timing of delivery, and choice of anesthesia. We evaluated the effect of MgSO\n                      <jats:sub>4<\/jats:sub>\n                      on raised ICP in severely preeclamptic patients using ultrasound-guided ONSD as a surrogate marker of ICP.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methodology:<\/jats:title>\n                    <jats:p>\n                      This prospective observational study was conducted after ethical committee approval and written informed consent from patients. Ultrasound-guided ONSD was measured and compared in 47 severe preeclamptic patients before and at 1 h, 4 h, 12 h, and 24 h after starting MgSO\n                      <jats:sub>4<\/jats:sub>\n                      therapy. The analysis of data was done by one-way analysis of variance using Statistical Package for the Social Science.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Mean ONSD was 5.56 \u00b1 0.30 mm in our study group. ONSD above 5.8 mm was seen in 17 (36.17%) patients and was considered as marker of raised ICP. There was a significant decrease in ONSD after 4 h of administration of MgSO\n                      <jats:sub>4<\/jats:sub>\n                      . No significant correlation was observed between mean arterial pressure, serum magnesium level, and ONSD.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      Ultrasound-guided ONSD measurement can be used as a quick, noninvasive bedside tool in severe preeclamptic patient on MgSO\n                      <jats:sub>4<\/jats:sub>\n                      treatment as marker of ICP which help us in determining clinical severity, therapeutic response, and to decide further course of management.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aer.aer_117_22","type":"journal-article","created":{"date-parts":[[2022,12,9]],"date-time":"2022-12-09T10:21:30Z","timestamp":1670581290000},"page":"366-372","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Ultrasonographic Changes in Transorbital Measurement of Optic Nerve Sheath Diameter in Magnesium Sulfate-Treated Severely Preeclamptic Patients"],"prefix":"10.4103","volume":"16","author":[{"given":"Kanchan","family":"Rani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Payal","family":"Jain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sushil D.","family":"Bhogawar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Radhika S.","family":"Bhogawar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mukesh Kumar","family":"Prasad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit Kumar","family":"Choudhary","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-15-20240901","doi-asserted-by":"crossref","first-page":"242","DOI":"10.12688\/f1000research.12249.1","article-title":"Recent advances in the diagnosis and management of pre-eclampsia","volume":"7","author":"Duhig","year":"2018","journal-title":"F1000Res"},{"key":"R2-15-20240901","first-page":"3","article-title":"Pre-eclampsia and eclampsia: An update on the pharmacological treatment applied in portugal","volume":"5","author":"Peres","year":"2018","journal-title":"J Cardiovasc Dev Dis"},{"key":"R3-15-20240901","doi-asserted-by":"crossref","first-page":"23905","DOI":"10.3390\/ijms161023905","article-title":"Cardiovascular complications of pregnancy","volume":"16","author":"Gongora","year":"2015","journal-title":"Int J Mol Sci"},{"key":"R4-15-20240901","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1097\/01.AOG.0000437382.03963.88","article-title":"Hypertension in pregnancy: Executive summary","volume":"122","author":"Roberts","year":"2013","journal-title":"Obstet and gynecol"},{"key":"R5-15-20240901","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.earlhumdev.2016.09.007","article-title":"Preeclampsia; short and long-term consequences for mother and neonate","volume":"102","author":"Bokslag","year":"2016","journal-title":"Early Hum Dev"},{"key":"R6-15-20240901","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1186\/s12884-022-04548-8","article-title":"Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls","volume":"19","author":"Sterrett","year":"2022","journal-title":"BMC Pregnancy Childbirth"},{"key":"R7-15-20240901","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1097\/ALN.0b013e31824c16e4","article-title":"Imaging intracranial pressure: An introduction to ultrasonography of the optic nerve sheath","volume":"116","author":"Rollins","year":"2012","journal-title":"Anesthesiology"},{"key":"R8-15-20240901","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1080\/00016340801915127","article-title":"Impaired maternal cognitive functioning after pregnancies complicated by severe pre-eclampsia: A pilot case-control study","volume":"87","author":"Bruss\u00e9","year":"2008","journal-title":"Acta Obstet Gynecol Scand"},{"key":"R9-15-20240901","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.12998\/wjcc.v7.i13.1535","article-title":"Intracranial pressure monitoring: Gold standard and recent innovations","volume":"7","author":"Nag","year":"2019","journal-title":"World J Clin Cases"},{"key":"R10-15-20240901","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1111\/j.1399-6576.2011.02432.x","article-title":"Ultrasonography of the optic nerve in neurocritically ill patients","volume":"55","author":"Moretti","year":"2011","journal-title":"Acta Anaesthesiol Scand"},{"key":"R11-15-20240901","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1007\/s00134-014-3392-7","article-title":"Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury","volume":"40","author":"Sekhon","year":"2014","journal-title":"Intensive Care Med"},{"key":"R12-15-20240901","doi-asserted-by":"crossref","first-page":"42","DOI":"10.4103\/aer.AER_218_17","article-title":"Ultrasonographic optic nerve sheath diameter as a surrogate measure of raised intracranial pressure in severe pregnancy-induced hypertension patients","volume":"12","author":"Singh","year":"2018","journal-title":"Anesth Essays Res"},{"key":"R13-15-20240901","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1007\/s00464-015-4458-5","article-title":"The relationship between intracranial pressure and obesity: An ultrasonographic evaluation of the optic nerve","volume":"30","author":"Dip","year":"2016","journal-title":"Surg Endosc"},{"key":"R14-15-20240901","first-page":"e4145","article-title":"Optic nerve sheath diameter correlation with elevated intracranial pressure determined via ultrasound","volume":"11","author":"Munawar","year":"2019","journal-title":"Cureus"},{"key":"R17-15-20240901","doi-asserted-by":"crossref","first-page":"298","DOI":"10.3109\/01443615.2010.549972","article-title":"A randomised comparative study between low-dose intravenous magnesium sulphate and standard intramuscular regimen for treatment of eclampsia","volume":"31","author":"Bhattacharjee","year":"2011","journal-title":"J Obstet Gynaecol"},{"key":"R18-15-20240901","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"R19-15-20240901","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1097\/ALN.0b013e318246ea1a","article-title":"Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: A pilot study","volume":"116","author":"Dubost","year":"2012","journal-title":"Anesthesiology"},{"key":"R20-15-20240901","doi-asserted-by":"crossref","first-page":"262","DOI":"10.4103\/ija.IJA_473_16","article-title":"Ultrasonographic measurement of optic nerve sheath diameter: A point of care test helps in prognostication of intensive care unit patients","volume":"61","author":"Banerjee","year":"2017","journal-title":"Indian J Anaesth"},{"key":"R21-15-20240901","doi-asserted-by":"crossref","first-page":"e0183170","DOI":"10.1371\/journal.pone.0183170","article-title":"Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography","volume":"12","author":"Jeon","year":"2017","journal-title":"PLoS One"},{"key":"R22-15-20240901","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/S1701-2163(15)30662-9","article-title":"Magnesium sulphate for the management of preeclampsia and eclampsia in low and middle income countries: A systematic review of tested dosing regimens","volume":"36","author":"Gordon","year":"2014","journal-title":"J Obstet Gynaecol Can"},{"key":"R23-15-20240901","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1161\/STROKEAHA.108.527788","article-title":"Magnesium sulfate for the treatment of eclampsia: A brief review","volume":"40","author":"Euser","year":"2009","journal-title":"Stroke"},{"key":"R24-15-20240901","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1001\/jamaophthalmol.2017.6560","article-title":"Ultrasonography assessments of optic nerve sheath diameter as a noninvasive and dynamic method of detecting changes in intracranial pressure","volume":"136","author":"Wang","year":"2018","journal-title":"JAMA Ophthalmol"},{"key":"R25-15-20240901","doi-asserted-by":"crossref","first-page":"250","DOI":"10.3934\/medsci.2019.3.250","article-title":"Investigating the relationship between ultrasound measured optic nerve sheath diameter and preeclampsia","volume":"6","author":"Arzpeyma","year":"2019","journal-title":"AIMS Med Sci"},{"key":"R26-15-20240901","doi-asserted-by":"crossref","first-page":"14","DOI":"10.4103\/sja.SJA_887_20","article-title":"Effect of magnesium sulphate on the intracranial pressure of preeclampsia patients using ultrasound-guided optic nerve sheath diameter: A pilot study","volume":"15","author":"Omran","year":"2021","journal-title":"Saudi J Anaesth"},{"key":"R27-15-20240901","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","article-title":"Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients","volume":"34","author":"Geeraerts","year":"2008","journal-title":"Intensive Care Med"},{"key":"R28-15-20240901","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ijoa.2018.06.005","article-title":"Ocular ultrasonography for diagnosing increased intracranial pressure in patients with severe preeclampsia","volume":"36","author":"Brzan Simenc","year":"2018","journal-title":"Int J Obstet Anesth"}],"container-title":["Anesthesia Essays &amp; Researches"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_117_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:18:06Z","timestamp":1787757486000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_117_22"}},"subtitle":["A Prospective Observational Study"],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/aer.aer_117_22","relation":{},"ISSN":["0259-1162"],"issn-type":[{"value":"0259-1162","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7]]}}}