{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:29:20Z","timestamp":1787758160790,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The supraglottic airway device (SAD) has proved to be an appropriate alternative to endotracheal intubation in laparoscopic surgeries owing to various advantages, namely, decreased airway manipulation and stable hemodynamics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>We compared the efficacy in terms of oropharyngeal leak pressure (OLP) and safety of laryngeal mask airway (LMA)-Supreme (LMA-S), i-gel, and Baska mask in patients undergoing laparoscopic cholecystectomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>Ninety patients posted for elective laparoscopic cholecystectomy were selected for a prospective randomized comparative study in a tertiary care center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>The study comprised three groups of 30 each based on the different SADs used Group-LS with LMA-Supreme, Group-IG with i-gel, and Group-BM with Baska mask. The secondary objectives were device insertion time, ease of insertion, changes in the peak airway pressure (PAP), heart rate, mean arterial pressure, and airway complications (sore throat, dysphagia. dysphonia, lip\/tongue or dental injury, etc.) between three groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>\n                      The quantitative data were analyzed using the one-way analysis of variance test and Bonferroni\n                      <jats:italic toggle=\"yes\">post hoc<\/jats:italic>\n                      multiple comparison test. Qualitative data were compared using Chi.squared test\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      OLP was significantly higher (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.005) in the Baska mask than i-gel and LMA-S groups just after insertion and during carboperitonium. There was no significant difference in time for device insertion, number of attempts, ease of insertion, and use of manipulation (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.05). However, the gastric tube insertion time was significantly lower in Group BM (9.59 \u00b1 2.78) than Group IG with 12.79 \u00b1 3.47 and Group LS with 10.84 \u00b1 3.68 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). There were no significant differences between the groups with regard to changes in the PAP, heart rate, mean arterial pressure at different time intervals, and complications.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Baska mask provided a significantly higher OLP compared to i-gel and LMA-S without significant airway morbidity in laparoscopic surgeries.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aer.aer_23_22","type":"journal-article","created":{"date-parts":[[2022,8,9]],"date-time":"2022-08-09T07:58:49Z","timestamp":1660031929000},"page":"42-48","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of LMA Supreme, i-gel, and Baska Mask for Airway Management during Laparoscopic Cholecystectomy"],"prefix":"10.4103","volume":"16","author":[{"given":"Parul","family":"Sharma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujeet","family":"Rai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manoj","family":"Tripathi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepak","family":"Malviya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumita","family":"Kumari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Smarika","family":"Mishra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-8-20240901","doi-asserted-by":"crossref","first-page":"49","DOI":"10.20398\/jscr.v3i2.3567","article-title":"Laparoscopic versus open cholecystectomy: Complications and cost","volume":"3","author":"Medeiros","year":"2013","journal-title":"J Surg Clin Res"},{"key":"R2-8-20240901","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1097\/00005373-199208000-00019","article-title":"Effect of increased intra-abdominal pressure on hepatic arterial, portal venous, and hepatic microcirculatory blood flow","volume":"33","author":"Diebel","year":"1992","journal-title":"J Trauma"},{"key":"R3-8-20240901","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1213\/00000539-199410000-00018","article-title":"Prospective comparison of use of the laryngeal mask and endotracheal tube for ambulatory surgery","volume":"79","author":"Cork","year":"1994","journal-title":"Anesth Analg"},{"key":"R4-8-20240901","doi-asserted-by":"crossref","first-page":"e4598","DOI":"10.1097\/MD.0000000000004598","article-title":"Comparison between supraglottic airway devices and endotracheal tubes in patients undergoing laparoscopic surgery: A systematic review and meta-analysis","volume":"95","author":"Park","year":"2016","journal-title":"Medicine (Baltimore"},{"key":"R5-8-20240901","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1093\/bja\/aen174","article-title":"LMA- SupremeTM-A new single-use LMATM with gastric access: A report on its clinical efficacy","volume":"101","author":"Verghese","year":"2000","journal-title":"Br J Anaesth"},{"key":"R6-8-20240901","doi-asserted-by":"crossref","first-page":"455","DOI":"10.4097\/kjae.2015.68.5.455","article-title":"Comparison of i-gel\u00ae and LMA Supreme\u00ae during laparoscopic cholecystectomy","volume":"68","author":"Park","year":"2015","journal-title":"Korean J Anesthesiol"},{"key":"R7-8-20240901","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1111\/j.1365-2044.2012.07140.x","article-title":"An observational study of the Baska\u00ae mask: A novel supraglottic airway","volume":"67","author":"Alexiev","year":"2012","journal-title":"Anaesthesia"},{"key":"R8-8-20240901","doi-asserted-by":"crossref","first-page":"23","DOI":"10.4103\/2249-4472.99313","article-title":"The Baska Mask-A new concept in self-sealing membrane cuff extraglottic airway devices using a sump and two gastric drains: A critical evaluation","volume":"2","author":"Van Zundert","year":"2012","journal-title":"J Obstet Anaesth Crit Care"},{"key":"R9-8-20240901","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1093\/bja\/84.5.650","article-title":"The LMA 'ProSeal'-A laryngeal mask with an oesophageal vent","volume":"84","author":"Brain","year":"2000","journal-title":"Br J Anaesth"},{"key":"R10-8-20240901","doi-asserted-by":"crossref","first-page":"319","DOI":"10.4240\/wjgs.v7.i11.319","article-title":"Role of laryngeal mask airway in laparoscopic cholecystectomy","volume":"7","author":"Bele\u00f1a","year":"2015","journal-title":"World J Gastrointest Surg"},{"key":"R11-8-20240901","doi-asserted-by":"crossref","first-page":"576","DOI":"10.4097\/kja.19195","article-title":"Comparison of clinical performance of i-gel\u00ae and Baska Mask\u00ae during laparoscopic cholecystectomy","volume":"72","author":"Choi","year":"2019","journal-title":"Korean J Anesthesiol"},{"key":"R12-8-20240901","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0889-8537(05)70208-X","article-title":"Physiologic changes during laparoscopy","volume":"19","author":"O'Malley","year":"2001","journal-title":"Anesthesiol Clin North Am"},{"key":"R13-8-20240901","first-page":"233","article-title":"A comparative analysis of the Baska mask vs. Proseal laryngeal mask for general anesthesia with IPPV","volume":"17","author":"Al-Rawahi","year":"2013","journal-title":"Anaesth Pain Intensive Care"},{"key":"R14-8-20240901","doi-asserted-by":"crossref","first-page":"634320","DOI":"10.1155\/2015\/634320","article-title":"Comparison of the proseal, supreme, and i-gel SAD in gynecological laparoscopic surgeries","volume":"2015","author":"Mukadder","year":"2015","journal-title":"ScientificWorldJournal"},{"key":"R15-8-20240901","doi-asserted-by":"crossref","first-page":"2","DOI":"10.4172\/2155-6148.1000647","article-title":"Supraglottic airway devices: A review in a new era of airway management","volume":"7","author":"Almeida","year":"2016","journal-title":"J Anesth Clin Res"},{"key":"R16-8-20240901","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s12871-016-0291-1","article-title":"I-Gel is a suitable alternative to endotracheal tubes in the laparoscopic pneumoperitoneum and trendelenburg position","volume":"17","author":"Lai","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R17-8-20240901","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1111\/anae.12356","article-title":"Comparison of the Baska(\u00ae) mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery","volume":"68","author":"Alexiev","year":"2013","journal-title":"Anaesthesia"},{"key":"R18-8-20240901","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1111\/j.1365-2044.2010.06534.x","article-title":"Comparison of the LMA Supreme vs. the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation","volume":"65","author":"Teoh","year":"2010","journal-title":"Anaesthesia"},{"key":"R19-8-20240901","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1097\/EJA.0b013e328345a413","article-title":"Intraocular pressure and haemodynamic responses to insertion of the i-gel, laryngeal mask airway or endotracheal tube","volume":"28","author":"Ismail","year":"2011","journal-title":"Eur J Anaesthesiol"},{"key":"R20-8-20240901","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.bjan.2012.12.008","article-title":"Can SupremeTM laryngeal mask airway be an alternative to endotracheal intubation in laparoscopic surgery?","volume":"64","author":"Aydogmus","year":"2014","journal-title":"Braz J Anesthesiol"},{"key":"R21-8-20240901","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/00000542-200007000-00009","article-title":"Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females","volume":"93","author":"Brimacombe","year":"2000","journal-title":"Anesthesiology"}],"container-title":["Anesthesia Essays &amp; Researches"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_23_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:08:25Z","timestamp":1787756905000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_23_22"}},"subtitle":["A Prospective Randomized Comparative Study from North India"],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/aer.aer_23_22","relation":{},"ISSN":["0259-1162"],"issn-type":[{"value":"0259-1162","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}