{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:35:52Z","timestamp":1786739752497,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>Video laryngoscopes resemble traditional laryngoscopes, but they have a video chip embedded in the tip of laryngoscope blade. This enables the operator to \u201clook around the corners\u201d which is not possible with conventional direct laryngoscopes. The present study was undertaken to compare Truview video laryngoscope and Macintosh laryngoscope for glottis visualization, ease of tracheal intubation, and associated hemodynamic response.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>The study was conducted in operation theater in a medical college.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>It was a randomized prospective observational study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Sixty patients of American Society of Anesthesiologists Grade 1 and 2 of either sex aged 18\u201360 years who were scheduled to undergo elective surgery requiring general anesthesia with orotracheal intubation were selected. In patients of Group T (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 30), intubation was done using Truview video laryngoscope, while in Group M (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 30), intubation was done using Macintosh laryngoscope. Various airway and hemodynamic parameters were assessed and compared.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>\n                      Statistical analysis was done using Chi-square test, paired and unpaired Student's\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test, and ANOVA test.\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 is considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Distribution of modified Mallampati Class (MMPC), ease of laryngoscopic blade insertion, and size of cuffed endotracheal tube used were statistically comparable in both the groups. The time to intubation was more in Group T (37.16 \u00b1 8.23 s) as compared to Group M (29.80 \u00b1 6.75 s). There was a statistically significant better modified Cormack and Lehane (CL) grading view obtained in Group T as compared to Group M (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.025). CL Grades 2 and 3 were not seen in any of either of the group. The mean intubation difficulty score (IDS) was significantly lower in Group T (0.3 \u00b1 0.60) as compared to Group M (0.73 \u00b1 0.86). In both the Groups T and M, the mean heart rate, systolic blood pressure (BP), and diastolic BP were significantly increased from baseline for up to 3 min after laryngoscopy, but they were comparable between the two groups all the time.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Truview propaganda cum distribution laryngoscope provides a better glottis view than the Macintosh laryngoscope. Although it requires a longer time to intubate using Truview, the overall IDS score was lower as compared to Macintosh laryngoscope. Hemodynamic changes remained similar in both the groups.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aer.aer_62_21","type":"journal-article","created":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T15:16:53Z","timestamp":1630336613000},"page":"73-80","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A Comparative Study between Truview PCD Video Laryngoscope and Macintosh Laryngoscope with Respect to Intubation Quality and Hemodynamic Changes"],"prefix":"10.4103","volume":"15","author":[{"given":"Rajiba Lochan","family":"Samal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumita","family":"Swain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soumya","family":"Samal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-14-20240901","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/00000542-199005000-00010","article-title":"Adverse respiratory events in anesthesia: A closed claims analysis","volume":"72","author":"Caplan","year":"1990","journal-title":"Anesthesiology"},{"key":"R2-14-20240901","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1097\/00000542-199908000-00030","article-title":"The American Society of Anesthesiologists Closed Claims Project: What have we learned, how has it affected practice, and how will it affect practice in the future?","volume":"91","author":"Cheney","year":"1999","journal-title":"Anesthesiology"},{"key":"R3-14-20240901","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/00000542-200507000-00009","article-title":"Management of the difficult airway: A closed claims analysis","volume":"103","author":"Peterson","year":"2005","journal-title":"Anesthesiology"},{"key":"R4-14-20240901","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.jclinane.2006.11.004","article-title":"Comparison of haemodynamic responses to orotracheal intubation with GlideScope video laryngoscopy and Macintosh direct laryngoscope","volume":"19","author":"Xue","year":"2007","journal-title":"J Clin Anesth"},{"key":"R5-14-20240901","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1007\/s12630-013-9906-x","article-title":"Comparison of the Truview PCD\u2122 and the GlideScope(\u00ae) video laryngoscopes with direct laryngoscopy in pediatric patients: A randomized trial","volume":"60","author":"Riveros","year":"2013","journal-title":"Can J Anaesth"},{"key":"R7-14-20240901","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","article-title":"Difficult tracheal intubation in obstetrics","volume":"39","author":"Cormack","year":"1984","journal-title":"Anaesthesia"},{"key":"R8-14-20240901","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1097\/00000542-199712000-00005","article-title":"The intubation difficulty scale (IDS): Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation","volume":"87","author":"Adnet","year":"1997","journal-title":"Anesthesiology"},{"key":"R9-14-20240901","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1111\/j.1365-2044.2007.05143.x","article-title":"A comparison of the Truview blade with the Macintosh blade in adult patients","volume":"62","author":"Barak","year":"2007","journal-title":"Anaesthesia"},{"key":"R10-14-20240901","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1111\/j.1365-2044.2007.05182.x","article-title":"An evaluation of the TruView EVO2 laryngoscope","volume":"62","author":"Li","year":"2007","journal-title":"Anaesthesia"},{"key":"R11-14-20240901","doi-asserted-by":"crossref","first-page":"276","DOI":"10.4103\/0019-5049.115621","article-title":"Role of the Truview EVO2 laryngoscope in the airway management of elective surgical patients: A comparison with the Macintosh laryngoscope","volume":"57","author":"Saxena","year":"2013","journal-title":"Indian J Anaesth"},{"key":"R12-14-20240901","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1093\/bja\/aen231","article-title":"Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization","volume":"101","author":"Malik","year":"2008","journal-title":"Br J Anaesth"},{"key":"R13-14-20240901","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1097\/EJA.0b013e32833f539f","article-title":"Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients","volume":"27","author":"Inal","year":"2010","journal-title":"Eur J Anaesthesiol"},{"key":"R14-14-20240901","doi-asserted-by":"crossref","first-page":"20","DOI":"10.4103\/aer.AER_16_20","article-title":"Comparative evaluation of McGrath MAC, Truview Video laryngoscopes and Macintosh laryngoscope for endotracheal intubation in patients undergoing surgery under general anaesthesia","volume":"14","author":"Kaur","year":"2020","journal-title":"Anesth Essays Res"},{"key":"R15-14-20240901","first-page":"164","article-title":"Evaluation of Truview EVO2 laryngoscope in anticipated difficult intubation \u2013 A comparison to Macintosh laryngoscope","volume":"53","author":"Singh","year":"2009","journal-title":"Indian J Anaesth"},{"key":"R16-14-20240901","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.jclinane.2016.09.010","article-title":"Comparison of the effects of Truview PCD\u2122 video laryngoscopy and Macintosh blade direct laryngoscopy in geriatric patients","volume":"35","author":"Kurnaz","year":"2016","journal-title":"J Clin Anesth"},{"key":"R17-14-20240901","doi-asserted-by":"crossref","first-page":"372","DOI":"10.4103\/0259-1162.143152","article-title":"A comparative study between Truview (PCD) laryngoscope and Macintosh laryngoscope in viewing glottic opening and ease of intubation: A crossover study","volume":"8","author":"Bag","year":"2014","journal-title":"Anesth Essays Res"},{"key":"R18-14-20240901","doi-asserted-by":"crossref","first-page":"308","DOI":"10.4103\/aer.AER_7_19","article-title":"Hemodynamic response to orotracheal intubation: Comparison between Macintosh, McCoy, and C-MAC video laryngoscope","volume":"13","author":"Aggarwal","year":"2019","journal-title":"Anesth Essays Res"}],"container-title":["Anesthesia Essays &amp; Researches"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_62_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:32:23Z","timestamp":1786735943000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_62_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/aer.aer_62_21","relation":{},"ISSN":["0259-1162"],"issn-type":[{"value":"0259-1162","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}