{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:36:09Z","timestamp":1786739769294,"version":"build-2736575974"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Objectives:<\/jats:title>\n                    <jats:p>Tracheal intubation using laryngoscopy is a fundamental skill, for an anesthesiologist. However, teaching this skill is difficult since Macintosh direct laryngoscope (DL) allows only one individual to view the larynx during the procedure. Hence, this study aimed to determine whether King Vision\u00ae videolaryngoscope (KVL) provides any advantage over direct laryngoscopy in teaching this skill to airway novices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>In this prospective randomized crossover study, Ethical Committee clearance was obtained from the institutional review board (MSRMC\/EC\/2017) and the study was registered with Clinical Trial Registry. After informed consent, 53 medical students were allotted to perform laryngoscopy and endotracheal intubation on a manikin by using either KVL or Macintosh DL. The participants first performed laryngoscopy with either KVL or Macintosh DL following a brief instruction and then crossed over to the second arm of the study to perform laryngoscopy using the other scope. The primary outcome measure was the time for successful endotracheal intubation. The secondary outcome measures were incidence of esophageal intubation (EI), excess application of pressure on maxillary teeth excess maxillary pressure, and success rate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Mean time for endotracheal intubation was significantly faster using KVL than in DL (44.64 vs. 87.72 s;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). No significant difference was found in the incidence of esophageal intubation 15.1% in KVL group versus 24.5% in DL group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.223). In the KVL group, 81.1% did not apply pressure on maxillary teeth versus 26.4% in the DL group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). The success rate of intubation was 100% in the KVL group versus 86.8% in the DL group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.006).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The KVL is a more effective tool to teach endotracheal intubation in comparison to Macintosh laryngoscope in airway novice medical students. Clinical trial registry India registration number: CTRI\/2017\/11\/010491.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aer.aer_72_21","type":"journal-article","created":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T15:16:53Z","timestamp":1630336613000},"page":"57-61","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["A Comparative Study in Airway Novices Using King Vision Videolaryngoscope and Conventional Macintosh Direct Laryngoscope for Endotracheal Intubation"],"prefix":"10.4103","volume":"15","author":[{"given":"Vinayak Seenappa","family":"Pujari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balaji","family":"Thiyagarajan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alagu","family":"Annamalai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yatish","family":"Bevinaguddaiah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. C.","family":"Manjunath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leena Harshad","family":"Parate","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-11-20240901","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1097\/00000542-200301000-00007","article-title":"Laryngoscopic intubation: Learning and performance","volume":"98","author":"Mulcaster","year":"2003","journal-title":"Anesthesiology"},{"key":"R2-11-20240901","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1046\/j.1365-2923.2002.01260.x","article-title":"Improving learning of a clinical skill: The first year's experience of teaching endotracheal intubation in a clinical simulation facility","volume":"36","author":"Owen","year":"2002","journal-title":"Med Educ"},{"key":"R3-11-20240901","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/BF03027728","article-title":"Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients","volume":"52","author":"Cooper","year":"2005","journal-title":"Can J Anaesth"},{"key":"R4-11-20240901","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1093\/bja\/aei041","article-title":"The GlideScope Video Laryngoscope: Randomized clinical trial in 200 patients","volume":"94","author":"Sun","year":"2005","journal-title":"Br J Anaesth"},{"key":"R5-11-20240901","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/j.1365-2044.2006.04819.x","article-title":"A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial","volume":"61","author":"Maharaj","year":"2006","journal-title":"Anaesthesia"},{"key":"R6-11-20240901","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1111\/j.1365-2044.2009.06061.x","article-title":"A comparison of McGrath and Macintosh laryngoscopes in novice users: A manikin study","volume":"64","author":"Ray","year":"2009","journal-title":"Anaesthesia"},{"key":"R7-11-20240901","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00540-013-1666-9","article-title":"Comparison of intubation performance between the King Vision and Macintosh laryngoscopes in novice personnel: A randomized, crossover manikin study","volume":"28","author":"Akihisa","year":"2014","journal-title":"J Anesth"},{"key":"R8-11-20240901","first-page":"253","article-title":"Video-guided versus direct laryngoscopy: Considerations for using simulation to teach inexperienced medical students","volume":"46","author":"Prescher","year":"2014","journal-title":"Simulation Series"},{"key":"R9-11-20240901","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1186\/s12871-017-0362-y","article-title":"Comparison of VividTrac(R), Airtraq(R), King Vision(R), Macintosh Laryngoscope and a Custom-Made Video laryngoscope for difficult and normal airways in mannequins by novices","volume":"17","author":"Rendeki","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R10-11-20240901","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.jemermed.2014.02.008","article-title":"Comparison of the king vision video laryngoscope with the macintosh laryngoscope","volume":"47","author":"Murphy","year":"2014","journal-title":"J Emerg Med"},{"key":"R11-11-20240901","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1093\/bja\/aen211","article-title":"Video-assisted instruction improves the success rate for tracheal intubation by novices","volume":"101","author":"Howard-Quijano","year":"2008","journal-title":"Br J Anaesth"},{"key":"R12-11-20240901","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/1471-227X-9-9","article-title":"Comparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation","volume":"9","author":"Maharaj","year":"2009","journal-title":"BMC Emerg Med"},{"key":"R13-11-20240901","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1213\/ane.0b013e31818d1904","article-title":"Forces applied to the maxillary incisors during video-assisted intubation","volume":"108","author":"Lee","year":"2009","journal-title":"Anesth Analg"},{"key":"R14-11-20240901","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/j.1365-2044.2010.06307.x","article-title":"Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins","volume":"65","author":"McElwain","year":"2010","journal-title":"Anaesthesia"},{"key":"R15-11-20240901","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/SIH.0b013e318197d2e5","article-title":"Comparison of intubation success of video laryngoscopy versus direct laryngoscopy in the difficult airway using high-fidelity simulation","volume":"4","author":"Narang","year":"2009","journal-title":"Simul Healthc"},{"key":"R16-11-20240901","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1093\/bja\/aew058","article-title":"Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: A multicentre randomized controlled trial","volume":"116","author":"Kleine-Brueggeney","year":"2016","journal-title":"Br J Anaesth"},{"key":"R17-11-20240901","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1111\/j.1365-2044.2007.05323.x","article-title":"The use of the BERCI DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation","volume":"63","author":"Low","year":"2008","journal-title":"Anaesthesia"},{"key":"R18-11-20240901","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1213\/00000539-199803000-00037","article-title":"Learning manual skills in anesthesiology: Is there a recommended number of cases for anesthetic procedures?","volume":"86","author":"Konrad","year":"1998","journal-title":"Anesth Analg"},{"key":"R19-11-20240901","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","article-title":"Video-laryngoscopes in the adult airway management: A topical review of the literature","volume":"54","author":"Niforopoulou","year":"2010","journal-title":"Acta Anaesthesiol Scand"},{"key":"R20-11-20240901","doi-asserted-by":"crossref","first-page":"4692","DOI":"10.3233\/WOR-2012-0112-4692","article-title":"Ergonomics of novices and experts during simulated endotracheal intubation","volume":"41","author":"de Laveaga","year":"2012","journal-title":"Work"},{"key":"R21-11-20240901","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s12871-016-0296-9","article-title":"Transfer of skills and comparison of performance between king vision\u00ae video laryngoscope and macintosh blade following an AHA airway management course","volume":"17","author":"Wolf","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R22-11-20240901","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1093\/bja\/65.2.268","article-title":"Rapidity and accuracy of tracheal intubation in a mannequin: Comparison of the fibreoptic with the Bullard laryngoscope","volume":"65","author":"Dyson","year":"1990","journal-title":"Br J Anaesth"},{"key":"R23-11-20240901","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1007\/BF03018415","article-title":"Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways","volume":"51","author":"Lim","year":"2004","journal-title":"Can J Anaesth"},{"key":"R24-11-20240901","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1111\/j.1365-2044.2006.04547.x","article-title":"Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy \u2013 A manikin study","volume":"61","author":"Maharaj","year":"2006","journal-title":"Anaesthesia"},{"key":"R25-11-20240901","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1111\/j.1365-2044.2008.05653.x","article-title":"Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated difficult airways*","volume":"63","author":"Savoldelli","year":"2008","journal-title":"Anaesthesia"}],"container-title":["Anesthesia Essays &amp; Researches"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_72_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:32:48Z","timestamp":1786735968000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_72_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/aer.aer_72_21","relation":{},"ISSN":["0259-1162"],"issn-type":[{"value":"0259-1162","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}