{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:32:48Z","timestamp":1787758368186,"version":"build-2784847793"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The use of a double-lumen endotracheal tube is one of the common anesthetic techniques for operations in the thoracic cavity. However, when compared to a single-lumen tube, placement of a double-lumen tube is technically more difficult as a result of which it takes more time to insert and is associated with more complications such as mucosal injury, hoarseness, and sore throat, even in patients with no anticipated airway difficulty. The CMAC D-blade that is usually used in patients with anticipated airway difficulty, could assist in smooth and quick placement of double-lumen tube (DLT) even in patients with no anticipated airway difficulty.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim of the Study:<\/jats:title>\n                    <jats:p>This study aimed to evaluate the effectiveness of the C-MAC D-blade in reducing the time taken to visualize the glottis and intubate patients with normal airway with a double-lumen tube.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting and Design:<\/jats:title>\n                    <jats:p>This was a prospective open-label randomized control trial in a tertiary hospital.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>Seventy-three consenting adult patients with physical status classes I and II, as determined by the American Society of Anesthesiologists, scheduled to undergo elective thoracotomy, were randomly allocated to receive either C-MAC D-blade (Group D) or Macintosh blade (Group M). The primary objective was to compare the time taken for visualization of the glottis and intubation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      Chi-square\/Fisher's exact test and\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test were used for statistical analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Seventy-three patients were randomized (Group D = 36; Group M = 37). Time to visualize the glottic structures (4.56 \u00b1 2.396 s vs. 7.27 \u00b1 4.891 s,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.01) was significantly better in Group D; however, the mean intubation time was comparable (55.92 \u00b1 18.749 s vs. 51.08 \u00b1 15.269 s,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.61).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>C-MAC D-blade videolaryngoscope offers a better glottic view and lesser time to visualize glottis when compared with the Macintosh laryngoscope. However, the time taken to insert the DLT after visualization was longer. We infer that there is no advantage in the routine use of C-MAC D-blade for DLT insertion in patients with no anticipated airway difficulty.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aer.aer_81_22","type":"journal-article","created":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T07:51:16Z","timestamp":1667202676000},"page":"289-295","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["A Randomised Control Study Comparing C-MAC D-Blade Video Laryngoscope (Hyper Angulated Blade) and Macintosh Laryngoscope for Insertion of a Double-Lumen Tube in Patients Undergoing Elective Thoracotomy"],"prefix":"10.4103","volume":"16","author":[{"given":"Amit","family":"Mathew","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roy Rajan","family":"Mathai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernice","family":"Theodore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Chandy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bijesh","family":"Yadav","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgene","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj","family":"Sahajanandan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R3-1-20240901","doi-asserted-by":"crossref","first-page":"266","DOI":"10.4103\/joacp.JOACP_79_20","article-title":"A randomized control led study comparing CMAC video laryngoscope and Macintosh laryngoscope for insertion of double lumen tube in patients undergoing elective thoracotomy","volume":"37","author":"Mathew","year":"2021","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R4-1-20240901","first-page":"121","article-title":"Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: A randomized, controlled comparison in patients with suspected difficult airways","volume":"79","author":"Serocki","year":"2013","journal-title":"Minerva Anestesiol"},{"key":"R5-1-20240901","first-page":"1011","article-title":"A new difficult airway management algorithm based upon the El Ganzouri Risk Index and GlideScope\u00ae videolaryngoscope. A new look for intubation?","volume":"77","author":"Caldiroli","year":"2011","journal-title":"Minerva Anestesiol"},{"key":"R6-1-20240901","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1213\/00000539-199902000-00014","article-title":"Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter","volume":"88","author":"Chow","year":"1999","journal-title":"Anesth Analg"},{"key":"R7-1-20240901","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1097\/00000542-199712000-00002","article-title":"Intubation difficulty scale: Anticipated best use","volume":"87","author":"Benumof","year":"1997","journal-title":"Anesthesiology"},{"key":"R8-1-20240901","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1111\/j.1365-2044.2008.05781.x","article-title":"Comparison of the Glidescope\u00ae and Airtraq\u00ae optical laryngoscopes in patients undergoing direct microlaryngoscopy","volume":"64","author":"Lange","year":"2009","journal-title":"Anaesthesia"},{"key":"R9-1-20240901","doi-asserted-by":"crossref","first-page":"312","DOI":"10.4103\/0019-5049.181591","article-title":"A randomized clinical trial comparing the standard Mcintosh laryngoscope and the C-Mac D blade Video laryngoscope\u2122 for double lumen tube insertion for one lung ventilation in onco surgical patients","volume":"60","author":"Shah","year":"2016","journal-title":"Indian J Anaesth"},{"key":"R10-1-20240901","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1111\/j.1365-2044.2011.07049.x","article-title":"Comparison of the GlideScope\u00ae videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation","volume":"67","author":"Hsu","year":"2012","journal-title":"Anaesthesia"},{"key":"R11-1-20240901","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1111\/anae.12322","article-title":"A randomised controlled trial comparing the GlideScope(\u00ae) and the Macintosh laryngoscope for double-lumen endobronchial intubation","volume":"68","author":"Russell","year":"2013","journal-title":"Anaesthesia"},{"key":"R12-1-20240901","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1111\/anae.14226","article-title":"Videolaryngoscopy vs. Macintosh laryngoscopy for double-lumen tube intubation in thoracic surgery: A systematic review and meta-analysis","volume":"73","author":"Liu","year":"2018","journal-title":"Anaesthesia"},{"key":"R13-1-20240901","doi-asserted-by":"crossref","first-page":"930","DOI":"10.5811\/westjem.2014.9.23691","article-title":"Learning curves for direct laryngoscopy and GlideScope\u00ae video laryngoscopy in an emergency medicine residency","volume":"15","author":"Sakles","year":"2014","journal-title":"West J Emerg Med"},{"key":"R14-1-20240901","doi-asserted-by":"crossref","first-page":"e0238060","DOI":"10.1371\/journal.pone.0238060","article-title":"Different classes of videoscopes and direct laryngoscopes for double-lumen tube intubation in thoracic surgery: A systematic review and network meta-analysis","volume":"15","author":"Kim","year":"2020","journal-title":"PLoS One"},{"key":"R15-1-20240901","doi-asserted-by":"crossref","first-page":"S479","DOI":"10.1007\/s00464-006-0038-z","article-title":"Seeing is believing: The importance of video laryngoscopy in teaching and in managing the difficult airway","volume":"20","author":"Kaplan","year":"2006","journal-title":"Surg Endosc"},{"key":"R16-1-20240901","doi-asserted-by":"crossref","first-page":"218","DOI":"10.4103\/1658-354X.168804","article-title":"Videolaryngoscopes for placement of double lumen tubes: Is it time to say goodbye to direct view?","volume":"10","author":"El-Tahan","year":"2016","journal-title":"Saudi J Anaesth"},{"key":"R17-1-20240901","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1007\/s12630-009-9243-2","article-title":"Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScope","volume":"57","author":"Bustamante","year":"2010","journal-title":"Can J Anaesth"},{"key":"R18-1-20240901","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1111\/j.1365-2044.2011.06777.x","article-title":"Videolaryngoscopy and Cormack and Lehane grading","volume":"66","author":"Angadi","year":"2011","journal-title":"Anaesthesia"},{"key":"R19-1-20240901","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1016\/j.ajem.2015.05.003","article-title":"Tips and troubleshooting for use of the GlideScope Video laryngoscope for emergency endotracheal intubation","volume":"33","author":"Bacon","year":"2015","journal-title":"Am J Emerg Med"},{"key":"R20-1-20240901","doi-asserted-by":"crossref","first-page":"339","DOI":"10.4097\/kjae.2011.60.5.339","article-title":"A comparative study on the usefulness of the Glidescope or Macintosh laryngoscope when intubating normal airways","volume":"60","author":"Choi","year":"2011","journal-title":"Korean J Anesthesiol"}],"container-title":["Anesthesia Essays &amp; Researches"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_81_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:13:22Z","timestamp":1787757202000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aer.aer_81_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/aer.aer_81_22","relation":{},"ISSN":["0259-1162"],"issn-type":[{"value":"0259-1162","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7]]}}}