{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T16:20:27Z","timestamp":1787847627026,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose :<\/jats:title>\n                    <jats:p>Fenestrated atrial septal defects (F-ASDs) in the pediatric population pose a challenge for transcatheter device closure since multiple devices are not preferred in small hearts. Oversizing the Amplatzer Septal Occluder (ASO) to cover the surrounding fenestrations usually distorts the central waist as well as the disc profile and often defeats the purpose. This is a retrospective observational study with an aim to assess the feasibility and safety of cribriform ASO in closing F-ASDs in small children.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Sixteen children with F-ASD who underwent device closure with cribriform ASO were included in the study. The fenestrated septal length (FSL) and the total septal length (TSL) were measured on transesophageal echocardiogram. A device size which was 1.5\u20132 times the FSL but smaller than the TSL was selected. The defect was closed with a device passed through a relatively centrally placed smaller fenestration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The median age of the cohort was 5 years (2.5\u201310.5). Majority (14\/16) required 25 or 30 mm cribriform ASO. Aneurysmal interatrial septum was seen in most of our patients (11\/15). All the patients had successful device implantation. Complete closure of the defect was seen in 11 patients while 5 patients had insignificant residual shunt at a median follow-up of 40 months (1\u201360 months). There were no other complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Cribriform ASO can be used safely and effectively in closing F-ASDs in children. Deployment of the device through a small central hole allows covering maximum fenestrations and gives more stability to the device. Residual shunts, although not infrequent, are insignificant.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/apc.apc_69_20","type":"journal-article","created":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T15:13:12Z","timestamp":1617981192000},"page":"159-164","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Use of cribriform amplatzer septal occluder in the pediatric population"],"prefix":"10.4103","volume":"14","author":[{"given":"Priya","family":"Pradhan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sneha","family":"Jain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Supratim","family":"Sen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bharat","family":"Dalvi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-5-20240901","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1017\/S1047951100005369","article-title":"Transcatheter closure as standard treatment for most interatrial defects: Experience in 200 patients treated with the Amplatzer Septal Occluder","volume":"9","author":"Berger","year":"1999","journal-title":"Cardiol Young"},{"key":"R2-5-20240901","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/S0735-1097(03)00589-8","article-title":"Transcatheter closure of atrial septal defect in young children: Results and follow-up","volume":"42","author":"Butera","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"R3-5-20240901","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1002\/ccd.1187","article-title":"Morphological variations of secundum-type atrial septal defects: Feasibility for percutaneous closure using Amplatzer septal occluders","volume":"53","author":"Podnar","year":"2001","journal-title":"Catheter Cardiovasc Interv"},{"key":"R4-5-20240901","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.amjms.2016.05.029","article-title":"Simultaneous transcatheter closure of multiple atrial septal defects using dual amplatzer septal occluder devices","volume":"352","author":"Yang","year":"2016","journal-title":"Am J Med Sci"},{"key":"R5-5-20240901","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1002\/ccd.21145","article-title":"Multiple Amplatzer septal occluder devices for multiple atrial communications: Immediate and long-term follow-up results","volume":"70","author":"Awad","year":"2007","journal-title":"Catheter Cardiovasc Interv"},{"key":"R6-5-20240901","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.ijcard.2008.01.027","article-title":"Transcatheter closure of atrial septal defects with multiple devices in adults: Procedural and clinical outcomes","volume":"133","author":"Mahadevan","year":"2009","journal-title":"Int J Cardiol"},{"key":"R7-5-20240901","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1002\/1522-726X(200102)52:2<203::AID-CCD1048>3.0.CO;2-P","article-title":"Device closure of fenestrated atrial septal defects: Use of a single Amplatz atrial septal occluder after balloon atrial septostomy to create a single defect","volume":"52","author":"Carano","year":"2001","journal-title":"Catheter Cardiovasc Interv"},{"key":"R9-5-20240901","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1007\/s00246-007-9079-x","article-title":"Cribriform amplatzer device closure of fenestrated atrial septal defects: Feasibility and technical aspects","volume":"29","author":"Numan","year":"2008","journal-title":"Pediatr Cardiol"},{"key":"R10-5-20240901","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1016\/S0735-1097(85)80228-X","article-title":"Diagnosis and classification of atrial septal aneurysm by two-dimensional echocardiography: Report of 80 consecutive cases","volume":"6","author":"Hanley","year":"1985","journal-title":"J Am Coll Cardiol"},{"key":"R11-5-20240901","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1002\/(SICI)1097-0304(199811)45:3<257::AID-CCD8>3.0.CO;2-U","article-title":"Multiple atrial septal defects and patent ductus arteriosus: Successful outcome using two Amplatzer septal occluders and Gianturco coils","volume":"45","author":"Pedra","year":"1998","journal-title":"Cathet Cardiovasc Diagn"},{"key":"R12-5-20240901","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1053\/euhj.1999.1909","article-title":"Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography","volume":"21","author":"Cao","year":"2000","journal-title":"Eur Heart J"},{"key":"R13-5-20240901","first-page":"262","article-title":"Catheter closure of perforated secundum atrial septal defect under intracardiac echocardiographic guidance using a single amplatzer device: Feasibility of a new method","volume":"17","author":"Zanchetta","year":"2005","journal-title":"J Invasive Cardiol"},{"key":"R14-5-20240901","doi-asserted-by":"crossref","first-page":"e326","DOI":"10.1161\/CIRCULATIONAHA.107.754069","article-title":"Images in cardiovascular medicine. Incomplete endothelialization and late development of acute bacterial endocarditis after implantation of an Amplatzer septal occluder device","volume":"117","author":"Slesnick","year":"2008","journal-title":"Circulation"},{"key":"R15-5-20240901","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1002\/ccd.10753","article-title":"Transcatheter closure of double atrial septal defects with a single Amplatzer device","volume":"61","author":"Szkutnik","year":"2004","journal-title":"Catheter Cardiovasc Interv"},{"key":"R16-5-20240901","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/s40119-012-0009-5","article-title":"Fenestrated atrial septal defect percutaneously occluded by a single device: Procedural and financial considerations","volume":"2","author":"Tal","year":"2013","journal-title":"Cardiol Ther"},{"key":"R17-5-20240901","first-page":"5395","article-title":"TCTAP C-241 Transcatheter closure of atrial septal aneurysm associated with multiple atrial septal defect","volume":"67","author":"Jihun","year":"2016","journal-title":"J Am Coll Cardiol"},{"key":"R18-5-20240901","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/S0002-9149(99)00916-9","article-title":"Sudden death in patients after transcatheter device implantation for congenital heart disease","volume":"85","author":"Perry","year":"2000","journal-title":"Am J Cardiol"},{"key":"R19-5-20240901","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/S0022-5223(99)70013-9","article-title":"Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects","volume":"118","author":"Berger","year":"1999","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R20-5-20240901","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1016\/S0735-1097(02)01711-4","article-title":"Early and late complications associated with transcatheter occlusion of secundum atrial septal defect","volume":"39","author":"Chessa","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"R21-5-20240901","doi-asserted-by":"crossref","first-page":"1836","DOI":"10.1016\/S0735-1097(02)01862-4","article-title":"Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial","volume":"39","author":"Du","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"R22-5-20240901","doi-asserted-by":"crossref","first-page":"549","DOI":"10.4070\/kcj.2011.41.9.549","article-title":"Transcatheter closure of multiple atrial septal defects with the amplatzer device","volume":"41","author":"Cho","year":"2011","journal-title":"Korean Circ J"}],"container-title":["Annals of Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/apc.APC_69_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T15:24:56Z","timestamp":1787844296000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/apc.APC_69_20"}},"subtitle":["Feasibility, safety, and technical considerations"],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/apc.apc_69_20","relation":{},"ISSN":["0974-2069"],"issn-type":[{"value":"0974-2069","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}