{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:31:45Z","timestamp":1787758305519,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>Dysfunctional right ventricular outflow tracts after a repair for tetralogy of Fallot using a transannular patch offer limited nonsurgical opportunities due to their large dimensions. A discrete subannular narrowing between a dilated right ventricle and the enlarged pulmonary trunk was a potential anatomical target for the creation of a landing zone using a prestent in a young male with severe pulmonary regurgitation and moderate stenosis. Asymmetric expansion of the prestent in the angulated outflow tract led to distal stent embolization that was stabilized by another telescoping stent before successful valve implantation. This manuscript details the unique challenges posed by a dilated regurgitant outflow tract for implanting a pulmonary valve.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/apc.apc_86_21","type":"journal-article","created":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T08:35:48Z","timestamp":1660811748000},"page":"175-179","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Unique challenges posed by a dysfunctional native right ventricular outflow tract for percutaneous pulmonary valve implantation using SAPIEN-S3 valve"],"prefix":"10.4103","volume":"15","author":[{"given":"Kothandam","family":"Sivakumar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramyashri","family":"Chandrasekaran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziyad M.","family":"Hijazi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-11-20240901","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1016\/j.jacc.2011.07.040","article-title":"Percutaneous implantation of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: Early Phase 1 results from an international multicenter clinical trial","volume":"58","author":"Kenny","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"R2-11-20240901","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1016\/j.jcin.2017.05.034","article-title":"Harmony feasibility trial: Acute and short-term outcomes with a self-expanding transcatheter pulmonary valve","volume":"10","author":"Bergersen","year":"2017","journal-title":"JACC Cardiovasc Interv"},{"key":"R3-11-20240901","doi-asserted-by":"crossref","first-page":"6422","DOI":"10.21037\/jtd-20-1621","article-title":"Transcatheter pulmonary valve replacement: An option for some but not for all","volume":"12","author":"Bavishi","year":"2020","journal-title":"J Thorac Dis"},{"key":"R4-11-20240901","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1002\/ccd.27973","article-title":"Initial results from the off-label use of the SAPIEN S3 valve for percutaneous transcatheter pulmonary valve replacement: A multi-institutional experience","volume":"93","author":"Sinha","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"key":"R5-11-20240901","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1016\/j.jcin.2018.05.051","article-title":"Safety and feasibility of melody transcatheter pulmonary valve replacement in the native right ventricular outflow tract: A multicenter pediatric heart network scholar study","volume":"11","author":"Martin","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"R6-11-20240901","doi-asserted-by":"crossref","first-page":"S264","DOI":"10.21037\/cdt.2019.09.08","article-title":"The Sapien valve provides enough grip to be implanted in pulmonary position without a pre-stent","volume":"9","author":"Tanase","year":"2019","journal-title":"Cardiovasc Diagn Ther"},{"key":"R7-11-20240901","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.acvd.2019.12.004","article-title":"Right ventricular outflow tract prestenting with AndraStent XXL before percutaneous pulmonary valve implantation","volume":"113","author":"Karsenty","year":"2020","journal-title":"Arch Cardiovasc Dis"},{"key":"R8-11-20240901","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1017\/S1047951119001264","article-title":"A word of caution: Diabolic behaviour of AndraStents\u00ae: Inflation of supporting balloon leads to \u201cdiabolo\u201d-misconfiguration of the stent","volume":"29","author":"Happel","year":"2019","journal-title":"Cardiol Young"},{"key":"R9-11-20240901","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1540-8183.2011.00638.x","article-title":"Medium-term outcomes for peripheral pulmonary artery stenting in adults with congenital heart disease","volume":"24","author":"Kenny","year":"2011","journal-title":"J Interv Cardiol"},{"key":"R10-11-20240901","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1002\/ccd.25383","article-title":"A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit","volume":"84","author":"Kobayashi","year":"2014","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Annals of Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/apc.apc_86_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:09:14Z","timestamp":1787756954000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/apc.apc_86_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":10,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/apc.apc_86_21","relation":{},"ISSN":["0974-2069"],"issn-type":[{"value":"0974-2069","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3]]}}}