{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T15:46:34Z","timestamp":1791215194559,"version":"4.1.0"},"reference-count":165,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The aim of this scoping review (ScR) according to the population, concept, and context question outline was: What factors can affect the accuracy of electronic apex locators (EALs) (concept) when determining the root canal terminus of human permanent teeth (population) in experimental studies (context)?<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A ScR was performed and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses for Scoping Reviews checklist using the following databases: PubMed\/Medline, Scopus, Web of Science, and ProQuest. Studies that investigated the influence of a factor on the accuracy of the EALs were screened and included according to the inclusion criteria.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 1761 records were retrieved, leading to 805 studies after duplicates were removed. Applying inclusion and exclusion criteria resulted in the inclusion of 166 studies. The 20 potential influencing factors include generation\/electrical working mechanism, method for application of EALs, root canal curvature, root canal length, tooth type, maxillary sinus proximity, lateral foramen, major apical foramen diameter\/file size, file alloy, apical patency, preflaring, apical periodontitis\/resorption, internal root resorption, perforation, irrigants, solvents, and medicaments, pulp contents, pulp vitality, orthodontic brackets, endodontic retreatment, and electromagnetic interferences were detected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although the accuracy of EALs is acceptable in most cases, the use of radiography along with EALs remains advisable to confirm the measurement in clinical scenarios.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/drj.drj_634_23","type":"journal-article","created":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T03:00:09Z","timestamp":1750993209000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Factors influencing the accuracy of electronic apex locators: A scoping review"],"prefix":"10.4103","volume":"22","author":[{"given":"Shayan","family":"Golkar","sequence":"first","affiliation":[{"name":"Department of Endodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abbasali","family":"Khademi","sequence":"additional","affiliation":[{"name":"Department of Endodontics, Dental Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amin","family":"Saatchi","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, University of P\u00e9cs, P\u00e9cs, Hungary, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Ghorani","sequence":"additional","affiliation":[{"name":"Post Graduate Student, Dental Research Committee, Department of Oral and Maxillofacial Surgery, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedram","family":"Iranmanesh","sequence":"additional","affiliation":[{"name":"Department of Endodontics, Dental Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,6]]},"reference":[{"key":"R1-20250627","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1046\/j.1365-2591.1998.00184.x","article-title":"Apical limit of root canal instrumentation and obturation, part 1","volume":"31","author":"Ricucci","year":"1998","journal-title":"Literature review. Int Endod J"},{"key":"R2-20250627","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/S1079-2104(05)80288-4","article-title":"Electronic canal length measurement","volume":"79","author":"Kobayashi","year":"1995","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R3-20250627","first-page":"420","article-title":"Exact method of locating the apical foramen","volume":"72","author":"Custer","year":"1918","journal-title":"Dent Regist"},{"key":"R4-20250627","doi-asserted-by":"crossref","first-page":"411","DOI":"10.5357\/koubyou1927.16.6_411","article-title":"Experimental study on iontophoresis","volume":"16","author":"Suzuki","year":"1942","journal-title":"Japanese J Stomatol"},{"key":"R5-20250627","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1177\/00220345620410020801","article-title":"New method for measuring the length of the root canal","volume":"41","author":"Sunada","year":"1962","journal-title":"J Dent Res"},{"key":"R6-20250627","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1111\/j.1365-2591.2006.01131.x","article-title":"The fundamental operating principles of electronic root canal length measurement devices","volume":"39","author":"Nekoofar","year":"2006","journal-title":"Int Endod J"},{"key":"R7-20250627","first-page":"173","article-title":"Influence of root canal curvature on the accuracy of root ZX electronic foramen locator: An in vitro study","volume":"12","author":"Saatchi","year":"2017","journal-title":"Iran Endod J"},{"key":"R8-20250627","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.joen.2013.11.012","article-title":"Influence of apical periodontitis on the accuracy of 3 electronic root canal length measurement devices: An in vivo study","volume":"40","author":"Saatchi","year":"2014","journal-title":"J Endod"},{"key":"R9-20250627","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.joen.2012.05.018","article-title":"In vivo evaluation of the raypex 5 by using different irrigants","volume":"38","author":"Gomes","year":"2012","journal-title":"J Endod"},{"key":"R10-20250627","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1111\/j.1365-2591.2006.01095.x","article-title":"Ex vivo accuracy of three electronic apex locators: Root ZX, elements diagnostic unit and apex locator and propex","volume":"39","author":"Plotino","year":"2006","journal-title":"Int Endod J"},{"key":"R11-20250627","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/j.1365-2591.2006.01199.x","article-title":"In vivo comparison of working length determination with two electronic apex locators","volume":"40","author":"Wrbas","year":"2007","journal-title":"Int Endod J"},{"key":"R12-20250627","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.joen.2010.08.048","article-title":"Comparison of the reliability of \u201c0.5\u201d and APEX: Mark measurements in two frequency-based electronic apex locators","volume":"37","author":"Jung","year":"2011","journal-title":"J Endod"},{"key":"R13-20250627","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/01.don.0000145422.94578.e6","article-title":"The role of apical instrumentation in root canal treatment: A review of the literature","volume":"31","author":"Baugh","year":"2005","journal-title":"J Endod"},{"key":"R14-20250627","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1038\/sj.bdj.2013.161","article-title":"An overview of electronic apex locators: Part 1","volume":"214","author":"Ali","year":"2013","journal-title":"Br Dent J"},{"key":"R15-20250627","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/0030-4220(77)90365-6","article-title":"Electronic ohmmeter","volume":"43","author":"Suchde","year":"1977","journal-title":"An electronic device for the determination of the root canal length. Oral Surg Oral Med Oral Pathol"},{"key":"R16-20250627","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/S0099-2399(06)81889-3","article-title":"Clinical evaluation of five electronic root canal length measuring instruments","volume":"16","author":"Fouad","year":"1990","journal-title":"J Endod"},{"key":"R17-20250627","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/S0099-2399(06)80053-1","article-title":"New electronic canal measuring device based on the ratio method","volume":"20","author":"Kobayashi","year":"1994","journal-title":"J Endod"},{"key":"R18-20250627","doi-asserted-by":"crossref","first-page":"7430","DOI":"10.3390\/app10217430","article-title":"Multifrequency impedance method based on neural network for root canal length measurement","volume":"10","author":"Qiao","year":"2020","journal-title":"Appl Sci"},{"key":"R19-20250627","doi-asserted-by":"crossref","first-page":"5893790","DOI":"10.1155\/2017\/5893790","article-title":"Root ZX electronic foramen locator: An ex vivo study of its three models' precision and reproducibility","volume":"2017","author":"Aguiar","year":"2017","journal-title":"Int J Dent"},{"key":"R20-20250627","doi-asserted-by":"crossref","first-page":"312","DOI":"10.5005\/jp-journals-10024-1534","article-title":"Ex vivo accuracy of root ZX II, root ZX mini and romiapex A-15 apex locators in extracted vital pulp teeth","volume":"15","author":"da Silva","year":"2014","journal-title":"J Contemp Dent Pract"},{"key":"R21-20250627","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1111\/j.1365-2591.2011.02010.x","article-title":"In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, raypex 5 and ProPex II","volume":"45","author":"Somma","year":"2012","journal-title":"Int Endod J"},{"key":"R22-20250627","first-page":"75","article-title":"Evaluation of the accuracy of electronic apex locators dentaport ZX and raypex 4 under clinical conditions","volume":"49","author":"Stavrianos","year":"2007","journal-title":"Folia Med (Plovdiv)"},{"key":"R23-20250627","first-page":"335","article-title":"Accuracy of three different electronic apex locators -A pilot study","volume":"8SE","author":"Prabhakar","year":"2015","journal-title":"BPJ"},{"key":"R24-20250627","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/aej.12074","article-title":"Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study","volume":"41","author":"Milanovic","year":"2015","journal-title":"Aust Endod J"},{"key":"R25-20250627","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1016\/j.joen.2017.03.039","article-title":"Determination of the accuracy of 5 electronic apex locators in the function of different employment protocols","volume":"43","author":"Oliveira","year":"2017","journal-title":"J Endod"},{"key":"R26-20250627","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1046\/j.1365-2591.1999.00202.x","article-title":"In vitro evaluation of the reliability of the root ZX electronic apex locator","volume":"32","author":"Ounsi","year":"1999","journal-title":"Int Endod J"},{"key":"R27-20250627","first-page":"27","article-title":"In vitro evaluation of two techniques to determine working length with an electronic apex locator","volume":"2","author":"Maia Filho","year":"2012","journal-title":"Dent Press Endod"},{"key":"R28-20250627","doi-asserted-by":"crossref","first-page":"583","DOI":"10.4103\/0972-0707.144610","article-title":"Influence of root canal curvature on the accuracy of an electronic apex locator: An in vitro study","volume":"17","author":"Santhosh","year":"2014","journal-title":"J Conserv Dent"},{"key":"R29-20250627","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3109\/00016357.2014.956144","article-title":"Influence of tooth length on the accuracy of the root ZX electronic apical foramen locator: An ex vivo study","volume":"73","author":"Saatchi","year":"2015","journal-title":"Acta Odontol Scand"},{"key":"R30-20250627","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1016\/j.joen.2011.02.011","article-title":"Accuracy of three electronic apex locators in anterior and posterior teeth: An ex vivo study","volume":"37","author":"Mancini","year":"2011","journal-title":"J Endod"},{"key":"R31-20250627","doi-asserted-by":"crossref","first-page":"3","DOI":"10.3390\/dj7010003","article-title":"Influence of the maxillary sinus on the accuracy of the root ZX apex locator: An ex vivo study","volume":"7","author":"El Hachem","year":"2019","journal-title":"Dent J (Basel)"},{"key":"R32-20250627","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/S0099-2399(98)80029-0","article-title":"A SEM study of in vivo accuracy of the root ZX electronic apex locator","volume":"24","author":"Pagavino","year":"1998","journal-title":"J Endod"},{"key":"R33-20250627","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.joen.2016.04.024","article-title":"The use of micro-computed tomography to determine the accuracy of 2 electronic apex locators and anatomic variations affecting their precision","volume":"42","author":"Piasecki","year":"2016","journal-title":"J Endod"},{"key":"R34-20250627","first-page":"c65","article-title":"Effects of simulated lateral canals on the accuracy of measurements by an electronic apex locator","volume":"78","author":"Uzun","year":"2012","journal-title":"J Can Dent Assoc"},{"key":"R35-20250627","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.joen.2013.09.032","article-title":"Not all electronic foramen locators are accurate in teeth with enlarged apical foramina: An in vitro comparison of 5 brands","volume":"40","author":"Akisue","year":"2014","journal-title":"J Endod"},{"key":"R36-20250627","doi-asserted-by":"crossref","first-page":"66","DOI":"10.4103\/0972-0707.148899","article-title":"In vitro evaluation of root ZX and raypex 6 in teeth with different apical diameters","volume":"18","author":"Aydin","year":"2015","journal-title":"J Conserv Dent"},{"key":"R37-20250627","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2298\/VSP160526057V","article-title":"Evaluation of odontometric methods in immature permanent teeth: Research for a better practice","volume":"76","author":"Vicko","year":"2019","journal-title":"Vojnosanit Pregl"},{"key":"R38-20250627","first-page":"101","article-title":"Ex vivo evaluation of the accuracy of raypex\u00ae5 in determining the minor diameter","volume":"14","author":"Cimilli","year":"2011","journal-title":"CDJ"},{"key":"R39-20250627","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0099-2399(06)81196-9","article-title":"Accuracy of the endex with variations in canal irrigants and foramen size","volume":"19","author":"Fouad","year":"1993","journal-title":"J Endod"},{"key":"R40-20250627","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1016\/j.joen.2011.05.007","article-title":"Critical diameter of apical foramen and of file size using the root ZX apex locator: An in vitro study","volume":"37","author":"Herrera","year":"2011","journal-title":"J Endod"},{"key":"R41-20250627","first-page":"C18","article-title":"Evaluation of correlation between apical diameter and file size using propex pixi apex locator","volume":"8","author":"Kolanu","year":"2014","journal-title":"J Clin Diagn Res"},{"key":"R42-20250627","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.joen.2007.05.009","article-title":"Influence of apical constriction diameter on root ZX apex locator precision","volume":"33","author":"Herrera","year":"2007","journal-title":"J Endod"},{"key":"R43-20250627","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1111\/aej.12235","article-title":"Influence of different sized files on the accuracy of two electronic apex locators","volume":"44","author":"Orosco","year":"2018","journal-title":"Aust Endod J"},{"key":"R44-20250627","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/j.1834-7819.2006.tb00419.x","article-title":"The effects of file size, sodium hypochlorite and blood on the accuracy of root ZX apex locator in enlarged root canals: An in vitro study","volume":"51","author":"Ebrahim","year":"2006","journal-title":"Aust Dent J"},{"key":"R45-20250627","first-page":"681","article-title":"The accuracy of the neosono ultima EZ apex locator using files of different alloys: An in vitro study","volume":"30","author":"Nekoofar","year":"2002","journal-title":"J Calif Dent Assoc"},{"key":"R46-20250627","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1097\/00004770-200310000-00012","article-title":"The accuracy of the root ZX electronic apex locator using stainless-steel and nickel-titanium files","volume":"29","author":"Thomas","year":"2003","journal-title":"J Endod"},{"key":"R47-20250627","doi-asserted-by":"crossref","first-page":"e788","DOI":"10.4317\/medoral.15.e788","article-title":"The accuracy of the Raypex 5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file","volume":"15","author":"Sadeghi","year":"2010","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"R48-20250627","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1111\/iej.12649","article-title":"Influence of instrument size and varying electrical resistance of root canal instruments on accuracy of three electronic root canal length measurement devices","volume":"50","author":"Aggarwal","year":"2017","journal-title":"Int Endod J"},{"key":"R49-20250627","first-page":"41","article-title":"Accuracy of the root ZX II using stainless-steel and nickel-titanium files","volume":"1","author":"da Silva","year":"2011","journal-title":"Dent Press Endod"},{"key":"R50-20250627","doi-asserted-by":"crossref","first-page":"8594087","DOI":"10.1155\/2016\/8594087","article-title":"The effect of file size and type and irrigation solutions on the accuracy of electronic apex locators: An in vitro study on canine teeth","volume":"2016","author":"Janeczek","year":"2016","journal-title":"Biomed Res Int"},{"key":"R51-20250627","doi-asserted-by":"crossref","first-page":"75","DOI":"10.2147\/CCIDE.S158882","article-title":"An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files","volume":"10","author":"Chaudhary","year":"2018","journal-title":"Clin Cosmet Investig Dent"},{"key":"R52-20250627","first-page":"75","article-title":"The precision of propex pixi with different instruments and coronal preflaring procedures","volume":"4","author":"Ferreira","year":"2019","journal-title":"Eur Endod J"},{"key":"R53-20250627","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/j.1365-2591.1996.tb01398.x","article-title":"Electronic length measurement using small and large files in enlarged canals","volume":"29","author":"Nguyen","year":"1996","journal-title":"Int Endod J"},{"key":"R54-20250627","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.joen.2008.02.019","article-title":"Influence of instrument size on the accuracy of different apex locators: An in vitro study","volume":"34","author":"Brise\u00f1o-Marroqu\u00edn","year":"2008","journal-title":"J Endod"},{"key":"R55-20250627","doi-asserted-by":"crossref","first-page":"6","DOI":"10.5395\/rde.2016.41.1.6","article-title":"An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files","volume":"41","author":"Gehlot","year":"2016","journal-title":"Restor Dent Endod"},{"key":"R56-20250627","first-page":"ZC01","article-title":"Clinical evaluation of effect of instrument size and type on the accuracy of electronic apex locator on upper premolars","volume":"11","author":"Biradar","year":"2017","journal-title":"JCDR"},{"key":"R57-20250627","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1038\/s41405-020-00052-3","article-title":"Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: An ex vivo study","volume":"6","author":"Shacham","year":"2020","journal-title":"BDJ Open"},{"key":"R58-20250627","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.joen.2020.01.010","article-title":"Impact of apical patency on accuracy of electronic apex locators: In vitro study","volume":"46","author":"Abdelsalam","year":"2020","journal-title":"J Endod"},{"key":"R59-20250627","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1111\/j.1365-2591.2004.00899.x","article-title":"A comparison between two electronic apex locators: An in vivo investigation","volume":"38","author":"Venturi","year":"2005","journal-title":"Int Endod J"},{"key":"R60-20250627","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1016\/j.joen.2015.06.009","article-title":"Ex vivo evaluation of the accuracy of electronic foramen locators in root canals with an obstructed apical foramen","volume":"41","author":"de Vasconcelos","year":"2015","journal-title":"J Endod"},{"key":"R61-20250627","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/j.1747-4477.2007.00049.x","article-title":"In vitro evaluation of the accuracy of five different electronic apex locators for determining the working length of endodontically retreated teeth","volume":"33","author":"Ebrahim","year":"2007","journal-title":"Aust Endod J"},{"key":"R62-20250627","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.joen.2008.10.017","article-title":"Consistency of apex locator function: A clinical study","volume":"35","author":"ElAyouti","year":"2009","journal-title":"J Endod"},{"key":"R63-20250627","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1590\/S1678-77572012000500008","article-title":"Effect of pre-flaring and file size on the accuracy of two electronic apex locators","volume":"20","author":"Brito-J\u00fanior","year":"2012","journal-title":"J Appl Oral Sci"},{"key":"R64-20250627","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.joen.2009.05.030","article-title":"Influence of preflaring on the accuracy of length determination with four electronic apex locators","volume":"35","author":"de Camargo","year":"2009","journal-title":"J Endod"},{"key":"R65-20250627","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/S0099-2399(99)80323-9","article-title":"Effect of preflaring on Root ZX apex locators","volume":"25","author":"Ibarrola","year":"1999","journal-title":"J Endod"},{"key":"R66-20250627","first-page":"331","article-title":"Preflaring effects on the accuracy of three electronic apex locators","volume":"26","author":"Morgental","year":"2011","journal-title":"Odontoscience Magazine"},{"key":"R67-20250627","first-page":"012059","article-title":"The effect of coronal preflaring on the accuracy of two electronic apex locators","volume":"884","author":"Suryantoro","year":"2017","journal-title":"J Phys"},{"key":"R68-20250627","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1590\/0103-6440202003282","article-title":"Influence of different coronal preflaring protocols on electronic foramen locators precision","volume":"31","author":"Melo","year":"2020","journal-title":"Braz Dent J"},{"key":"R69-20250627","doi-asserted-by":"crossref","first-page":"46","DOI":"10.4103\/JCD.JCD_4_19","article-title":"The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study","volume":"24","author":"Saritha","year":"2021","journal-title":"J Conserv Dent"},{"key":"R70-20250627","doi-asserted-by":"crossref","first-page":"2760","DOI":"10.3390\/jcm10132760","article-title":"Influence of coronal preflaring on the accuracy of electronic working length determination: Systematic review and meta-analysis","volume":"10","author":"Le\u00f3n-L\u00f3pez","year":"2021","journal-title":"J Clin Med"},{"key":"R71-20250627","first-page":"161","article-title":"Effect of endodontic preflaring on electronic determination of working length","volume":"26","author":"Lopez","year":"2011","journal-title":"Odontoscience Magazine"},{"key":"R72-20250627","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/j.joen.2016.07.022","article-title":"Changes in root canal length determined during mechanical preparation stages and their relationship with the accuracy of root ZX II","volume":"42","author":"Vasconcelos","year":"2016","journal-title":"J Endod"},{"key":"R73-20250627","doi-asserted-by":"crossref","first-page":"374971","DOI":"10.1155\/2014\/374971","article-title":"Apical dimension of root canal clinically assessed with and without periapical lesions","volume":"2014","author":"Gesi","year":"2014","journal-title":"Int J Dent"},{"key":"R74-20250627","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1111\/iej.12235","article-title":"Clinical accuracy of two electronic apex locators in teeth with large periapical lesions","volume":"47","author":"\u00c7al\u0131\u015fkan","year":"2014","journal-title":"Int Endod J"},{"key":"R75-20250627","first-page":"164","article-title":"Working length determination using cone-beam computed tomography, periapical radiography and electronic apex locator in teeth with apical periodontitis: A clinical study","volume":"11","author":"de Morais","year":"2016","journal-title":"Iran Endod J"},{"key":"R76-20250627","doi-asserted-by":"crossref","first-page":"S204","DOI":"10.4103\/2231-0762.149042","article-title":"In vivo evaluation of the accuracy of working length determination using an electronic apex locater IPEX (NSK) on vital uninfected teeth and teeth with radiographic evidence of periapical lesions","volume":"4","author":"Raghu","year":"2014","journal-title":"J Int Soc Prev Community Dent"},{"key":"R77-20250627","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1016\/j.joen.2016.06.010","article-title":"Evaluation of the reliability of cone-beam computed tomography scanning and electronic apex locator measurements in working length determination of teeth with large periapical lesions","volume":"42","author":"\u00dcst\u00fcn","year":"2016","journal-title":"J Endod"},{"key":"R78-20250627","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.joen.2011.06.006","article-title":"Accuracy of root ZX II in locating foramen in teeth with apical periodontitis: An in vivo study","volume":"37","author":"Piasecki","year":"2011","journal-title":"J Endod"},{"key":"R79-20250627","first-page":"52","article-title":"In vitro efficiency evaluation of an electronic apex locator in teeth with simulated root resorption","volume":"1","author":"da Silva","year":"2011","journal-title":"Dent Press Endod"},{"key":"R80-20250627","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1097\/00004770-200206000-00011","article-title":"In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption","volume":"28","author":"Goldberg","year":"2002","journal-title":"J Endod"},{"key":"R81-20250627","doi-asserted-by":"crossref","first-page":"402","DOI":"10.4103\/0972-0707.190002","article-title":"Comparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study","volume":"19","author":"Saraswathi","year":"2016","journal-title":"J Conserv Dent"},{"key":"R82-20250627","first-page":"288","article-title":"Influence of simulated apical resorption following orthodontic treatment on working length determination: An in vitro study","volume":"15","author":"Angerame","year":"2014","journal-title":"Eur J Paediatr Dent"},{"key":"R83-20250627","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1590\/0103-6440201902705","article-title":"Analysis of electronic apex locators in human teeth diagnosed with apical periodontitis","volume":"30","author":"Broon","year":"2019","journal-title":"Braz Dent J"},{"key":"R84-20250627","doi-asserted-by":"crossref","first-page":"5239","DOI":"10.1007\/s00784-021-03831-w","article-title":"The influence of periapical lesions on the repeatability of two electronic apex locators in vivo","volume":"25","author":"Adorno","year":"2021","journal-title":"Clin Oral Investig"},{"key":"R85-20250627","first-page":"607","article-title":"The influence of apical lesions on electronic tooth-length measurements \u2013 An in vitro study","volume":"15","author":"Ku\u017ami\u0144ski","year":"2006","journal-title":"Adv Clin Exp Med"},{"key":"R86-20250627","doi-asserted-by":"crossref","first-page":"624","DOI":"10.2478\/folmed-2018-0033","article-title":"Accuracy of different apex locators in teeth with simulated apical root resorption: An in vitro study","volume":"60","author":"Jadhav","year":"2018","journal-title":"Folia Med (Plovdiv)"},{"key":"R87-20250627","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1016\/j.joen.2014.02.004","article-title":"Accuracy and repeatability of 3 apex locators in locating root canal perforations: An ex vivo study","volume":"40","author":"D'Assun\u00e7\u00e3o","year":"2014","journal-title":"J Endod"},{"key":"R88-20250627","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1046\/j.1365-2591.1997.00107.x","article-title":"Reliability of different electronic apex locators to detect root perforations in vitro","volume":"30","author":"Kaufman","year":"1997","journal-title":"Int Endod J"},{"key":"R89-20250627","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s13005-014-0057-2","article-title":"Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: An ex vivo study","volume":"10","author":"Marroqu\u00edn","year":"2014","journal-title":"Head Face Med"},{"key":"R90-20250627","first-page":"23","article-title":"In vitro detection of simulated apical root perforation with two electronic apex locators","volume":"5","author":"Nazari Moghaddam","year":"2010","journal-title":"Iran Endod J"},{"key":"R91-20250627","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1111\/j.1600-9657.1999.tb00798.x","article-title":"Detection and measurement of endodontic root perforations using a newly designed apex-locating handpiece","volume":"15","author":"Zmener","year":"1999","journal-title":"Endod Dent Traumatol"},{"key":"R92-20250627","doi-asserted-by":"crossref","first-page":"407","DOI":"10.4103\/1735-3327.270779","article-title":"Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study","volume":"16","author":"Khatri","year":"2019","journal-title":"J Dent Res"},{"key":"R93-20250627","first-page":"6","article-title":"Comparative evaluation of accuracy of ipex, root zx mini, and epex pro apex locators in teeth with artificially created root perforations in presence of various intracanal irrigants","volume":"5","author":"Bilaiya","year":"2020","journal-title":"Eur Endod J"},{"key":"R94-20250627","doi-asserted-by":"crossref","first-page":"134","DOI":"10.4274\/meandros.galenos.2020.41196","article-title":"The effect of different irrigation solutions on the accuracy of two electronic apex locators in locating artificial root perforations","volume":"21","author":"Zeliha U\u011fur","year":"2020","journal-title":"Meandros Med Dental J"},{"key":"R95-20250627","doi-asserted-by":"crossref","first-page":"258","DOI":"10.33808\/clinexphealthsci.739588","article-title":"The effect of various canal contents on the accuracy of two electronic apex locators in detecting different size of root perforations","volume":"11","author":"Cankaya","year":"2021","journal-title":"Clin Exp Health Sci"},{"key":"R96-20250627","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/S1079-2104(96)80361-1","article-title":"Determination of location of root perforations by electronic apex locators","volume":"82","author":"Fuss","year":"1996","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R97-20250627","first-page":"184","article-title":"The accuracy of three apex locators in determining the location of strip root perforation in different environments","volume":"16","author":"Shekarchizade","year":"2021","journal-title":"Iran Endod J"},{"key":"R98-20250627","doi-asserted-by":"crossref","first-page":"1","DOI":"10.14295\/bds.2020.v23i1.1856","article-title":"Comparative evaluation of the effect of various irrigants and dry canal on electronic apex locators in locating simulated root perforations: An in vitro study","volume":"23","author":"Srivastava","year":"2020","journal-title":"Braz Dent Sci"},{"key":"R99-20250627","first-page":"3628","article-title":"Comparative evaluation of accuracy of detection of perforation in the presence of various irrigants using different apex locators-an in vitro study","volume":"8","author":"Sowmya","year":"2021","journal-title":"Int J Oral Sci"},{"key":"R100-20250627","doi-asserted-by":"crossref","first-page":"281","DOI":"10.4103\/njcp.njcp_1444_21","article-title":"The influence of MTAD and QMix on the accuracy of electronic apex locator in locating simulated perforations","volume":"25","author":"Dumani","year":"2022","journal-title":"Niger J Clin Pract"},{"key":"R101-20250627","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/00004770-200103000-00018","article-title":"An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants","volume":"27","author":"Jenkins","year":"2001","journal-title":"J Endod"},{"key":"R102-20250627","doi-asserted-by":"crossref","first-page":"e57","DOI":"10.1016\/j.tripleo.2008.04.001","article-title":"Accuracies of seven different apex locators under various conditions","volume":"106","author":"Kang","year":"2008","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R103-20250627","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1007\/s00784-015-1644-8","article-title":"Comparison of two electronic apex locators on human cadavers","volume":"20","author":"Marigo","year":"2016","journal-title":"Clin Oral Investig"},{"key":"R104-20250627","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1097\/00004770-200208000-00008","article-title":"The influence of sodium hypochlorite irrigation on the accuracy of the Root ZX electronic apex locator","volume":"28","author":"Meares","year":"2002","journal-title":"J Endod"},{"key":"R105-20250627","doi-asserted-by":"crossref","first-page":"182","DOI":"10.4103\/0970-4388.28074","article-title":"Accuracy of electronic apex locator in length determination in the presence of different irrigants: An in vitro study","volume":"24","author":"Muthu","year":"2006","journal-title":"J Indian Soc Pedod Prev Dent"},{"key":"R106-20250627","doi-asserted-by":"crossref","first-page":"457","DOI":"10.4314\/ejhs.v26i5.7","article-title":"An in vitro evaluation of the accuracy of two electronic apex locators to determine working length in the presence of various irrigants","volume":"26","author":"Prasad","year":"2016","journal-title":"Ethiop J Health Sci"},{"key":"R107-20250627","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1080\/00016357.2017.1307447","article-title":"Comparison of four electronic root canal length measurement devices","volume":"75","author":"S\u00fcbay","year":"2017","journal-title":"Acta Odontol Scand"},{"key":"R108-20250627","first-page":"e1054","article-title":"In vitro evaluation of the accuracy of the root zx in the presence of naocl 2.5% and chlorhexidine 0.2","volume":"10","author":"Bolbolian","year":"2018","journal-title":"J Clin Exp Dent"},{"key":"R109-20250627","first-page":"226","article-title":"Ex vivo evaluation of the accuracy of 3 electronic apex locators in different environments: A micro-computed tomography study","volume":"5","author":"\u00c7\u0131nar","year":"2020","journal-title":"Eur Endod J"},{"key":"R110-20250627","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1590\/S1806-83242010000400004","article-title":"Accuracy of three electronic apex locators in the presence of different irrigating solutions","volume":"24","author":"Carvalho","year":"2010","journal-title":"Braz Oral Res"},{"key":"R111-20250627","doi-asserted-by":"crossref","first-page":"863","DOI":"10.3390\/ma15030863","article-title":"Effect of sodium hypochlorite concentration on electronic apex locator reliability","volume":"15","author":"Diemer","year":"2022","journal-title":"Materials (Basel)"},{"key":"R112-20250627","doi-asserted-by":"crossref","first-page":"232","DOI":"10.4103\/endo.endo_122_21","article-title":"Accuracy of electronic apex locator in the presence of different irrigating solutions","volume":"33","author":"Jha","year":"2021","journal-title":"Endodontology"},{"key":"R113-20250627","first-page":"568","article-title":"In vitro comparison of working length determination using three different electronic apex locators","volume":"11","author":"Ku\u015ftarci","year":"2014","journal-title":"Dent Res J (Isfahan)"},{"key":"R114-20250627","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00004770-200203000-00004","article-title":"The effects of sodium hypochloride concentrations on the accuracy of an apex locating device","volume":"28","author":"T\u0131naz","year":"2002","journal-title":"J Endod"},{"key":"R115-20250627","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/j.joen.2016.10.031","article-title":"The influence of various irrigants on the accuracy of 2 electronic apex locators in locating simulated root perforations","volume":"43","author":"Altunba\u015f","year":"2017","journal-title":"J Endod"},{"key":"R116-20250627","doi-asserted-by":"crossref","first-page":"e41","DOI":"10.4317\/jced.51230","article-title":"A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions","volume":"6","author":"Khattak","year":"2014","journal-title":"J Clin Exp Dent"},{"key":"R117-20250627","doi-asserted-by":"crossref","first-page":"649","DOI":"10.5005\/jp-journals-10024-1379","article-title":"Accuracy of electronic apex locator in enlarged root canals with different root canal irrigants: An in vitro study","volume":"14","author":"Dinapadu","year":"2013","journal-title":"J Contemp Dent Pract"},{"key":"R118-20250627","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1111\/j.1834-7819.2007.tb00488.x","article-title":"An in vitro evaluation of the accuracy of dentaport ZX apex locator in enlarged root canals","volume":"52","author":"Ebrahim","year":"2007","journal-title":"Aust Dent J"},{"key":"R119-20250627","doi-asserted-by":"crossref","first-page":"178","DOI":"10.4103\/0972-0707.94585","article-title":"Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study","volume":"15","author":"Mull","year":"2012","journal-title":"J Conserv Dent"},{"key":"R120-20250627","doi-asserted-by":"crossref","first-page":"349","DOI":"10.4103\/jispcd.JISPCD_50_18","article-title":"Comparative evaluation of accuracy of two electronic apex locators in the presence of contemporary irrigants: An in vitro study","volume":"8","author":"Baruah","year":"2018","journal-title":"J Int Soc Prev Community Dent"},{"key":"R121-20250627","first-page":"56","article-title":"A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo\/ex vivo study","volume":"11","author":"Khursheed","year":"2014","journal-title":"Dent Res J (Isfahan)"},{"key":"R122-20250627","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s12903-019-0994-z","article-title":"The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators","volume":"20","author":"Marek","year":"2019","journal-title":"BMC Oral Health"},{"key":"R123-20250627","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1111\/j.1365-2591.2006.01050.x","article-title":"An ex vivo evaluation of a new root canal irrigation technique with intracanal aspiration","volume":"39","author":"Fukumoto","year":"2006","journal-title":"Int Endod J"},{"key":"R124-20250627","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1111\/j.1365-2591.2007.01234.x","article-title":"The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the tri auto ZX handpiece","volume":"40","author":"Erdemir","year":"2007","journal-title":"Int Endod J"},{"key":"R125-20250627","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1111\/j.1747-4477.2011.00323.x","article-title":"Effect of chloroform, orange solvent and eucalyptol on the accuracy of four electronic apex locators","volume":"39","author":"Al-Hadlaq","year":"2013","journal-title":"Aust Endod J"},{"key":"R126-20250627","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1111\/iej.12111","article-title":"Effect of solvents on the accuracy of the mini root ZX apex locator","volume":"46","author":"Er","year":"2013","journal-title":"Int Endod J"},{"key":"R127-20250627","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1111\/aej.12264","article-title":"Accuracy and consistency of electronic root canal length determination with electrically isolating rubber stoppers","volume":"45","author":"Kowollik","year":"2019","journal-title":"Aust Endod J"},{"key":"R128-20250627","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1111\/j.1365-2591.2006.01229.x","article-title":"A comparison between two electronic apex locators: An ex vivo investigation","volume":"40","author":"Venturi","year":"2007","journal-title":"Int Endod J"},{"key":"R129-20250627","doi-asserted-by":"crossref","first-page":"44","DOI":"10.5395\/rde.2015.40.1.44","article-title":"Calcium hydroxide dressing residues after different removal techniques affect the accuracy of root-ZX apex locator","volume":"40","author":"Uzunoglu","year":"2015","journal-title":"Restor Dent Endod"},{"key":"R130-20250627","doi-asserted-by":"crossref","first-page":"132","DOI":"10.3109\/00016357.2014.961027","article-title":"The effect of residual calcium hydroxide on the accuracy of a contemporary electronic apex locator","volume":"73","author":"Ustun","year":"2015","journal-title":"Acta Odontol Scand"},{"key":"R131-20250627","doi-asserted-by":"crossref","first-page":"48","DOI":"10.4103\/1735-3327.276235","article-title":"Influence of calcium hydroxide residues after using different irrigants on the accuracy of two electronic apex locators: An in vitro study","volume":"17","author":"Shojaee","year":"2020","journal-title":"Dent Res J (Isfahan)"},{"key":"R132-20250627","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1590\/0103-6440201600678","article-title":"Influence of blood on the accuracy of raypex 5 and root ZX electronic foramen locators: An in vivo study","volume":"27","author":"Saatchi","year":"2016","journal-title":"Braz Dent J"},{"key":"R133-20250627","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/0030-4220(93)90209-M","article-title":"Effect of recapitulation on accuracy of electronically determined canal length","volume":"76","author":"Rivera","year":"1993","journal-title":"Oral Surg Oral Med Oral Pathol"},{"key":"R134-20250627","doi-asserted-by":"crossref","first-page":"e129","DOI":"10.1016\/j.tripleo.2007.04.018","article-title":"Influence of pulp vitality on length determination by using the elements diagnostic unit and apex locator","volume":"104","author":"Akisue","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R135-20250627","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/S0099-2399(98)80214-8","article-title":"An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals","volume":"24","author":"Dunlap","year":"1998","journal-title":"J Endod"},{"key":"R136-20250627","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0099-2399(06)81283-5","article-title":"In vivo measurement accuracy in vital and necrotic canals with the endex apex locator","volume":"19","author":"Mayeda","year":"1993","journal-title":"J Endod"},{"key":"R137-20250627","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1590\/S1806-83242012000200004","article-title":"Influence of pulp condition on the accuracy of an electronic foramen locator in posterior teeth: An in vivo study","volume":"26","author":"Renner","year":"2012","journal-title":"Braz Oral Res"},{"key":"R138-20250627","doi-asserted-by":"crossref","first-page":"99","DOI":"10.4103\/sej.sej_35_17","article-title":"Determination of apical constriction and apical foramen using electronic apex locator in vivo: Comparison between vital and nonvital teeth","volume":"8","author":"Aggarwal","year":"2018","journal-title":"Saudi Endod J"},{"key":"R139-20250627","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1111\/aej.12321","article-title":"A comparative evaluation of two working length determination methods","volume":"45","author":"Keratiotis","year":"2019","journal-title":"Aust Endod J"},{"key":"R140-20250627","doi-asserted-by":"crossref","first-page":"e12408","DOI":"10.1111\/jicd.12408","article-title":"Comparison of three different apex locators in determining the working length of mandibular first molar teeth with irreversible pulpitis compared with an intraoral periapical radiograph: A block randomized, controlled, clinical trial","volume":"10","author":"Vanitha","year":"2019","journal-title":"J Investig Clin Dent"},{"key":"R141-20250627","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/00004770-200202000-00008","article-title":"Influence of the canal contents on the electrical assisted determination of the length of root canals","volume":"28","author":"Pommer","year":"2002","journal-title":"J Endod"},{"key":"R142-20250627","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.joen.2007.04.003","article-title":"In vivo evaluation of ProPex electronic apex locator","volume":"33","author":"Ozsezer","year":"2007","journal-title":"J Endod"},{"key":"R143-20250627","doi-asserted-by":"crossref","first-page":"6615560","DOI":"10.1155\/2021\/6615560","article-title":"Effect of orthodontic brackets on the accuracy of apex locators: A pilot study","volume":"2021","author":"\u015een \u00d6","year":"2021","journal-title":"Biomed Res Int"},{"key":"R144-20250627","first-page":"457","article-title":"Accuracy and reliability of a new electronic apex locator: An in-vivo study","volume":"12","author":"Chita","year":"2012","journal-title":"Brazilian Research in Pediatric Dentistry and Integrated Clinic"},{"key":"R145-20250627","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/01.don.0000155226.03483.ff","article-title":"In vitro evaluation of the ability of three apex locators to determine the working length during retreatment","volume":"31","author":"Goldberg","year":"2005","journal-title":"J Endod"},{"key":"R146-20250627","first-page":"138","article-title":"Accuracy of an electronic foramen locator in determining working length during retreatment: An in vitro study","volume":"30","author":"Lassen","year":"2015","journal-title":"Odontoscience Magazine"},{"key":"R147-20250627","first-page":"282","article-title":"In vitro evaluation of the precision of four different electronic apex locators in determining the working length of teeth after removing root canal obturation materials","volume":"2","author":"Stavrianos","year":"2008","journal-title":"J Res Med Sci"},{"key":"R148-20250627","doi-asserted-by":"crossref","first-page":"1526","DOI":"10.1016\/j.joen.2010.04.016","article-title":"An in vitro evaluation of performance of two electronic root canal length measurement devices during retreatment of different obturating materials","volume":"36","author":"Aggarwal","year":"2010","journal-title":"J Endod"},{"key":"R149-20250627","doi-asserted-by":"crossref","first-page":"125","DOI":"10.34172\/joddd.2020.026","article-title":"Evaluation of the accuracy of different apex locators in determining the working length during root canal retreatment","volume":"14","author":"Tufenkci","year":"2020","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"R150-20250627","doi-asserted-by":"crossref","first-page":"2061","DOI":"10.1016\/j.joen.2014.07.035","article-title":"Accuracy of an electronic apex locator in the retreatment of teeth obturated with plastic or cross-linked gutta-percha carrier-based materials: An ex vivo study","volume":"40","author":"Mancini","year":"2014","journal-title":"J Endod"},{"key":"R151-20250627","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/aej.12010","article-title":"Accuracy of the dentaport ZX apex locator for working length determination when retreating molar root canals","volume":"40","author":"Cimilli","year":"2014","journal-title":"Aust Endod J"},{"key":"R152-20250627","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1111\/j.1365-2591.2008.01450.x","article-title":"Effect of canal preparation and residual root filling material on root impedance","volume":"41","author":"Al-bulushi","year":"2008","journal-title":"Int Endod J"},{"key":"R153-20250627","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1111\/j.1600-9657.1997.tb00025.x","article-title":"Electrical impedance measurements of root canal length","volume":"13","author":"Meredith","year":"1997","journal-title":"Endod Dent Traumatol"},{"key":"R154-20250627","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1016\/j.joen.2015.02.007","article-title":"Do cell phones affect establishing electronic working length?","volume":"41","author":"Hurstel","year":"2015","journal-title":"J Endod"},{"key":"R155-20250627","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/j.joen.2015.12.027","article-title":"Evaluation of interference of cellular phones on electronic apex locators: An in vitro study","volume":"42","author":"Sidhu","year":"2016","journal-title":"J Endod"},{"key":"R156-20250627","first-page":"161","article-title":"Electromagnetic interference of smartphones on apex locators: An in vivo study","volume":"10","author":"Silva","year":"2016","journal-title":"ENDO"},{"key":"R157-20250627","doi-asserted-by":"crossref","first-page":"170","DOI":"10.4103\/JCD.JCD_252_16","article-title":"Can active signals of cellphone interfere with electronic working length determination of a root canal in a dental clinic? An in vivo study","volume":"20","author":"Gohil","year":"2017","journal-title":"J Conserv Dent"},{"key":"R158-20250627","doi-asserted-by":"crossref","first-page":"142","DOI":"10.4103\/2155-8213.195972","article-title":"Evaluating electromagnetic interference of communication devices with root ZX mini apex locator","volume":"7","author":"Shafieibavani","year":"2016","journal-title":"Dent Hypotheses"},{"key":"R159-20250627","first-page":"278","article-title":"Effect of various electronic devices on the performance of electronic apex locator","volume":"14","author":"Parirokh","year":"2019","journal-title":"Iran Endod J"},{"key":"R160-20250627","doi-asserted-by":"crossref","first-page":"1547071","DOI":"10.1080\/19932820.2018.1547071","article-title":"Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic devices: A systematic review","volume":"14","author":"AlRahabi","year":"2019","journal-title":"Libyan J Med"},{"key":"R161-20250627","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.jdent.2015.12.008","article-title":"Electromagnetic interference of endodontic equipments with cardiovascular implantable electronic device","volume":"46","author":"Dadalti","year":"2016","journal-title":"J Dent"},{"key":"R162-20250627","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1111\/iej.12000","article-title":"The effects of six electronic apex locators on pacemaker function: An in vitro study","volume":"46","author":"Gomez","year":"2013","journal-title":"Int Endod J"},{"key":"R163-20250627","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1111\/eos.12313","article-title":"Risk of electromagnetic interference induced by dental equipment on cardiac implantable electrical devices","volume":"124","author":"Miranda-Rius","year":"2016","journal-title":"Eur J Oral Sci"},{"key":"R164-20250627","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1111\/pace.14051","article-title":"Electromagnetic interference effect of dental equipment on cardiac implantable electrical devices: A systematic review","volume":"43","author":"Niu","year":"2020","journal-title":"Pacing Clin Electrophysiol"},{"key":"R165-20250627","doi-asserted-by":"crossref","first-page":"15","DOI":"10.4103\/0972-0707.148868","article-title":"Interference of apex locator, pulp tester and diathermy on pacemaker function","volume":"18","author":"Sriman","year":"2015","journal-title":"J Conserv Dent"}],"container-title":["Dental Research Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/drj.drj_634_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:44:47Z","timestamp":1787067887000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/drj.drj_634_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":165,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/drj.drj_634_23","relation":{},"ISSN":["1735-3327","2008-0255"],"issn-type":[{"value":"1735-3327","type":"print"},{"value":"2008-0255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6]]},"assertion":[{"value":"2023-10-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}