{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T12:10:39Z","timestamp":1792671039526,"version":"4.5.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Objectives:<\/jats:title>\n                    <jats:p>The AXIOS stent is indicated for transgastric or transduodenal drainage of symptomatic pancreatic pseudocysts and symptomatic walled off necrosis. The AXIOS stent functions as a conduit which allows solid and liquid pancreatic fluid collections (PFC) contents to pass into the luminal GI tract and also allows the passage of standard and therapeutic endoscopes into the PFC to perform endoscopic debridement. We aim to investigate the number and type of complications associated with AXIOS stents.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>We analyzed postmarketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database January 2016 to February 2021.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      During the study period, approximately 588 reports with 579 device issues and 250 patient complications were identified. Most device complications were due to stent positioning problems or stent malpositioning (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 206; 35.6%), followed by stent migration (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 72; 12.4%), premature deployment (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 61; 10.5%), material integrity (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 56; 9.6%), deployment failure (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 47; 8.1%), and difficulty removing the stent (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 45; 7.7%). The most reported patient adverse events were hemorrhage\/bleeding (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 81; 32.4%), perforation (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 26; 10.4%), pain (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 22; 8.8%), unspecified infection (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 20; 8.0%), and death (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 17; 6.8%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Findings from the MAUDE database highlight patient and device complications which endoscopists should be aware of before AXIOS stent placement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/eus-d-21-00096","type":"journal-article","created":{"date-parts":[[2022,1,25]],"date-time":"2022-01-25T12:54:49Z","timestamp":1643115289000},"page":"231-236","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":18,"title":["Adverse events associated with AXIOS stents"],"prefix":"10.1097","volume":"11","author":[{"given":"Daryl","family":"Ramai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Facciorusso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"DeLuca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Monique","family":"Barakat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas G.","family":"Adler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-9-20241018","doi-asserted-by":"crossref","first-page":"136","DOI":"10.4103\/eus.eus_58_18","article-title":"A pilot study of a 20-mm lumen-apposing metal stent to treat pancreatic fluid collections: First reported multicenter use of a new device","volume":"8","author":"Adler","year":"2019","journal-title":"Endosc Ultrasound"},{"key":"R2-9-20241018","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/j.gie.2015.10.020","article-title":"EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: A large retrospective, multicenter U.S. experience (with videos)","volume":"83","author":"Siddiqui","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"R3-9-20241018","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1016\/j.gie.2019.11.021","article-title":"International multicenter comprehensive analysis of adverse events associated with lumen-apposing metal stent placement for pancreatic fluid collection drainage","volume":"91","author":"Fugazza","year":"2020","journal-title":"Gastrointest Endosc"},{"key":"R4-9-20241018","first-page":"273","article-title":"International, multicenter retrospective trial comparing the efficacy and safety of bi-flanged versus lumen-apposing metal stents for endoscopic drainage of walled-off pancreatic necrosis","volume":"34","author":"Siddiqui","year":"2021","journal-title":"Ann Gastroenterol"},{"key":"R5-9-20241018","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.tgie.2019.150653","article-title":"Design considerations of the AXIOS stent and electrocautery enhanced delivery system","volume":"22","author":"Binmoeller","year":"2019","journal-title":"Tech Gastrointest Endosc"},{"key":"R7-9-20241018","first-page":"63","article-title":"A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: A prospective cohort study","volume":"47","author":"Walter","year":"2015","journal-title":"Endoscopy"},{"key":"R8-9-20241018","doi-asserted-by":"crossref","first-page":"E347","DOI":"10.1055\/a-0828-7630","article-title":"Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: A large international multicenter study","volume":"7","author":"Chen","year":"2019","journal-title":"Endosc Int Open"},{"key":"R9-9-20241018","doi-asserted-by":"crossref","first-page":"352","DOI":"10.4103\/eus.eus_39_20","article-title":"Why is EUS-guided cyst-gastrostomy more common than cyst-duodenostomy: A disease state or endoscopist preference","volume":"9","author":"Gabr","year":"2020","journal-title":"Endosc Ultrasound"},{"key":"R10-9-20241018","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1016\/j.gie.2016.08.014","article-title":"Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: Clinical outcomes and success","volume":"85","author":"Siddiqui","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"R11-9-20241018","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1016\/j.cgh.2016.05.011","article-title":"Endoscopic therapy with lumen-apposing metal stents is safe and effective for patients with pancreatic walled-off necrosis","volume":"14","author":"Sharaiha","year":"2016","journal-title":"Clin Gastroenterol Hepatol"},{"key":"R12-9-20241018","doi-asserted-by":"crossref","first-page":"A44","DOI":"10.1136\/gutjnl-2016-312388.72","article-title":"OC-073 the first multicentre experience from the UK and Ireland of the use of the hot axios system for transluminal drainage of pancreatic fluid collections","volume":"65","author":"Venkatachalapathy","year":"2016","journal-title":"Gut"},{"key":"R13-9-20241018","doi-asserted-by":"crossref","first-page":"82","DOI":"10.4103\/eus.eus_7_19","article-title":"Lumen apposing metal stents in drainage of pancreatic walled-off necrosis, are they any better than plastic stents? A systematic review and meta-analysis of studies published since the revised Atlanta classification of pancreatic fluid collections","volume":"8","author":"Mohan","year":"2019","journal-title":"Endosc Ultrasound"},{"key":"R14-9-20241018","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1097\/MPA.0000000000001798","article-title":"Comparison between lumen-apposing metal stents and plastic stents in endoscopic ultrasound-guided drainage of pancreatic fluid collection: A meta-analysis and systematic review","volume":"50","author":"Lyu","year":"2021","journal-title":"Pancreas"},{"key":"R15-9-20241018","doi-asserted-by":"crossref","first-page":"101","DOI":"10.4103\/eus.eus_80_19","article-title":"EUS-guided biliary drainage: A systematic review and meta-analysis","volume":"9","author":"Dhindsa","year":"2020","journal-title":"Endosc Ultrasound"},{"key":"R16-9-20241018","doi-asserted-by":"crossref","first-page":"E496","DOI":"10.1055\/a-1341-0788","article-title":"EUS-guided gastroenterostomy versus enteral stenting for gastric outlet obstruction: Systematic review and meta-analysis","volume":"9","author":"Chandan","year":"2021","journal-title":"Endosc Int Open"},{"key":"R17-9-20241018","doi-asserted-by":"crossref","first-page":"4964","DOI":"10.1007\/s00464-020-07758-3","article-title":"Endoscopic gallbladder drainage for symptomatic gallbladder disease: A cumulative systematic review meta-analysis","volume":"35","author":"McCarty","year":"2021","journal-title":"Surg Endosc"},{"key":"R18-9-20241018","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.gie.2018.08.047","article-title":"Single-stage EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction","volume":"89","author":"Anderloni","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"R19-9-20241018","doi-asserted-by":"crossref","first-page":"18","DOI":"10.21037\/tgh.2018.03.03","article-title":"Review of management options for pancreatic pseudocysts","volume":"3","author":"Agalianos","year":"2018","journal-title":"Transl Gastroenterol Hepatol"}],"container-title":["Endoscopic Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.4103\/EUS-D-21-00096","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,17]],"date-time":"2024-10-17T21:08:18Z","timestamp":1729199298000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.4103\/EUS-D-21-00096"}},"subtitle":["Insights from the manufacturer and user facility device experience database"],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/eus-d-21-00096","relation":{},"ISSN":["2303-9027"],"issn-type":[{"value":"2303-9027","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]}}}