{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:23:36Z","timestamp":1787757816747,"version":"build-2784847793"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The objective of this study was to determine the efficacy of modified thermal balloon ablation using Foley's catheter in the treatment of heavy menstrual bleeding (HMB).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      Twelve patients with HMB aged 35\u201355 years underwent modified thermal balloon ablation using Foley's catheter. Patients were selected after complete clinical evaluation and investigations. The procedure was undertaken in the operation theater under general anesthesia\/intravenous sedation. Three cycles of modified thermal balloon ablation using Foley's catheter were performed to ablate the endometrium. The time given to each cycle was 7 min. All the cycles were performed in the same setting. The main outcome measures that were studied were reduction in the menstrual flow, the need for further treatment, and relief of dysmenorrhea if present. Outcome measure regarding reduction in menstrual flow was statistically analyzed using Fisher's exact test. Statistical significance was determined at a level of\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Eighty-two percent of patients experienced a reasonable reduction in menstrual blood flow at 3-month follow-up. Eighteen percent observed no change in bleeding pattern and needed further treatment after failure of the procedure. Forty-two percent of patients complained of minor side effects such as cramp lower abdominal pain and fever. Rupture of balloon during the procedure occurred in only one case (8%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Modified thermal balloon ablation with Foley's catheter can be a promising management of HMB in resource-poor settings. It is a cost-effective alternative to the original endometrial ablation techniques.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/gmit.gmit_147_20","type":"journal-article","created":{"date-parts":[[2022,5,4]],"date-time":"2022-05-04T01:43:19Z","timestamp":1651628599000},"page":"100-104","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Modified Thermal Balloon Endometrial Ablation for Treatment of Heavy Menstrual Bleeding"],"prefix":"10.4103","volume":"11","author":[{"given":"Baraa Lukman Humo","family":"Al-Ibrahim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed Jasim Al","family":"Husaynei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R13-5-20240830","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s00404-007-0449-7","article-title":"Thermal balloon endometrial ablation: A systematic review","volume":"277","author":"Iavazzo","year":"2008","journal-title":"Arch Gynecol Obstet"},{"key":"R14-5-20240830","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1034\/j.1600-0412.2000.079001054.x","article-title":"Thermal endometrial ablation: A simple technique","volume":"79","author":"Singh","year":"2000","journal-title":"Acta Obstet Gynecol Scand"},{"key":"R15-5-20240830","first-page":"47","article-title":"Efficacy of modified thermal balloon ablation in heavy menstrual bleeding","volume":"3","author":"Naz","year":"2012","journal-title":"JUMDC"},{"key":"R16-5-20240830","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1007\/s00404-010-1744-2","article-title":"Modified thermal balloon endometrial ablation in low resource settings: A cost-effective method using Foley's catheter","volume":"284","author":"Helal","year":"2011","journal-title":"Arch Gynecol Obstet"},{"key":"R17-5-20240830","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/S0029-7844(98)00141-0","article-title":"Thermal balloon and rollerball ablation to treat menorrhagia: A multicenter comparison","volume":"92","author":"Meyer","year":"1998","journal-title":"Obstet Gynecol"},{"key":"R18-5-20240830","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1067\/S0002-9378(03)00403-4","article-title":"Efficacy of thermal balloon ablation in patients with abnormal uterine bleeding","volume":"189","author":"Feitoza","year":"2003","journal-title":"Am J Obstet Gynecol"},{"key":"R19-5-20240830","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.mefs.2011.12.002","article-title":"Endometrial thermal balloon ablation by a simple technique using Foley's catheter with or without pre ablation endometrial curettage to treat cases with intractable menorrhagia","volume":"17","author":"Azza","year":"2012","journal-title":"Middle East Fertility Soc J"},{"key":"R20-5-20240830","first-page":"732","article-title":"Preliminary clinical experience with a thermal balloon endometrial ablation method to treat menorrhagia","volume":"83","author":"Singer","year":"1994","journal-title":"Obstet Gynecol"},{"key":"R21-5-20240830","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1080\/00016340701797823","article-title":"Endometrial thermal balloon ablation has a beneficial long-term effect on menorrhagia","volume":"87","author":"Abonkallio","year":"2008","journal-title":"Acta Obstet Gynecol"},{"key":"R22-5-20240830","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1093\/humrep\/deg206","article-title":"Uterine endometrial thermal balloon therapy for the treatment of menorrhagia: Long-term multicentre follow-up study","volume":"18","author":"Amso","year":"2003","journal-title":"Hum Reprod"},{"key":"R23-5-20240830","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.crwh.2017.07.001","article-title":"Late-onset endometrial ablation failure","volume":"15","author":"Wortman","year":"2017","journal-title":"Case Rep Womens Health"}],"container-title":["Gynecology and Minimally Invasive Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/GMIT.GMIT_147_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:53:44Z","timestamp":1787756024000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/GMIT.GMIT_147_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/gmit.gmit_147_20","relation":{},"ISSN":["2213-3070"],"issn-type":[{"value":"2213-3070","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4]]}}}