{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:32:37Z","timestamp":1786739557721,"version":"build-2736575974"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      Seprafilm\n                      <jats:sup>\u00ae<\/jats:sup>\n                      is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm\n                      <jats:sup>\u00ae<\/jats:sup>\n                      safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopic hysterectomy for uterine leiomyoma. The quarter-pack is cut into three pieces. The film placed on the holder sheet was rolled up with forceps (or wrapped around forceps) and inserted into a 5 mm trocar. After application, the center of the short axis of the holder was pinched with a grasping forceps, and the holder was drawn out of the body through the trocar. Of the 36 pieces placed, Seprafilm\n                      <jats:sup>\u00ae<\/jats:sup>\n                      broke only in once. Insertion was successful in 100%, and the holder was successfully retrieved through the trocar in 92% (33\/36) of the cases. The holder may be easily retrieved after application. This technique represents an extremely simple versatile application method in operations in which only 5-mm trocars can be used.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/gmit.gmit_36_20","type":"journal-article","created":{"date-parts":[[2021,8,3]],"date-time":"2021-08-03T00:46:44Z","timestamp":1627951604000},"page":"168-170","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["A New Technique for Seprafilm\u00ae That Can Be Practiced with a 5-mm Trocar"],"prefix":"10.4103","volume":"10","author":[{"given":"Rikiya","family":"Sano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiaki","family":"Ota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamaki","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soichiro","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichiro","family":"Shimoya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuru","family":"Shiota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-7-20240830","first-page":"CD000475","article-title":"Barrier agents for adhesion prevention after gynaecological surgery","volume":"4","author":"Ahmad","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"R2-7-20240830","doi-asserted-by":"crossref","first-page":"2125","DOI":"10.1007\/s00268-007-9242-9","article-title":"Efficacy and safety of Seprafilm for preventing postoperative abdominal adhesion: Systematic review and meta-analysis","volume":"31","author":"Zeng","year":"2007","journal-title":"World J Surg"},{"key":"R3-7-20240830","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00464-002-8845-3","article-title":"Results after laparoscopic lysis of adhesions and placement of Seprafilm for intractable abdominal pain","volume":"17","author":"Khaitan","year":"2003","journal-title":"Surg Endosc"},{"key":"R4-7-20240830","doi-asserted-by":"crossref","first-page":"S19","DOI":"10.1016\/j.ajog.2011.09.030","article-title":"Adhesion prevention in patients with multiple cesarean deliveries","volume":"205","author":"Bates","year":"2011","journal-title":"Am J Obstet Gynecol"},{"key":"R5-7-20240830","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1089\/lap.2006.16.497","article-title":"A novel instrument and technique for using Seprafilm hyaluronic acid\/carboxymethylcellulose membrane during laparoscopic myomectomy","volume":"16","author":"Takeuchi","year":"2006","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R6-7-20240830","doi-asserted-by":"crossref","first-page":"e13","DOI":"10.1097\/SLE.0b013e31828f6ec1","article-title":"Usefulness of moistening Seprafilm before use in laparoscopic surgery","volume":"24","author":"Kusuki","year":"2014","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R7-7-20240830","doi-asserted-by":"crossref","first-page":"e181","DOI":"10.1097\/SLE.0b013e3181b9302d","article-title":"An easy technique for laparoscopic placement of Seprafilm","volume":"19","author":"Ortiz","year":"2009","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R8-7-20240830","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1007\/s00464-014-3813-2","article-title":"Multi-layered intra-abdominal adhesion prophylaxis following laparoscopic colorectal surgery","volume":"29","author":"Tsuruta","year":"2015","journal-title":"Surg Endosc"},{"key":"R9-7-20240830","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.jmig.2014.02.016","article-title":"Modified novel technique for improving the success rate of applying Seprafilm by using laparoscopy","volume":"21","author":"Chuang","year":"2014","journal-title":"J Minim Invasive Gynecol"},{"key":"R10-7-20240830","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ejogrb.2019.12.033","article-title":"Cellulose absorbable barrier for prevention of de-novo adhesion formation at the time of laparoscopic myomectomy: A systematic review and meta-analysis of randomized controlled trials","volume":"245","author":"Raimondo","year":"2020","journal-title":"Eur J Obstet Gynecol Reprod Biol"}],"container-title":["Gynecology and Minimally Invasive Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/GMIT.GMIT_36_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:29:58Z","timestamp":1786735798000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/GMIT.GMIT_36_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/gmit.gmit_36_20","relation":{},"ISSN":["2213-3070"],"issn-type":[{"value":"2213-3070","type":"print"}],"subject":[],"published":{"date-parts":[[2021,7]]}}}