{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:23:19Z","timestamp":1787757799467,"version":"build-2784847793"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>ABSTRACT<\/jats:title>\n                    <jats:p>Transcatheter aortic valve implantation (TAVI) is one of the rapidly evolving treatment strategies for severe aortic stenosis. Included in this category are inoperable, high, intermediate, and low surgical risk patients. It has varying types of complications that may require urgent surgical or transcatheter interventions to prevent procedural mortality and morbidity. Coronary artery occlusion is a rare and dreaded complication of TAVI. Here, we report a 73-year-old man who was diagnosed with severe aortic stenosis and underwent transfemoral TAVI. Unfortunately, during preimplantation balloon valvuloplasty, the patient developed severe hypotension along with ischemic changes on the electrocardiographic monitor. Promptly, coronary angiography was performed which revealed complete occlusion of the left anterior descending artery secondary to embolic debris. He was successfully rescued by manual aspiration thrombectomy (MAT). MAT results in restoration of coronary flow and reversal of shock condition before completing TAVI procedure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/heartviews.heartviews_27_22","type":"journal-article","created":{"date-parts":[[2022,5,16]],"date-time":"2022-05-16T05:12:39Z","timestamp":1652677959000},"page":"55-59","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Coronary Artery Occlusion during Transcatheter Aortic Valve Implantation"],"prefix":"10.4103","volume":"23","author":[{"given":"Mohamed Abdunasser M.","family":"Baghi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khaled Taufek","family":"Othman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdu Rahman H.","family":"Alnabti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salem M.","family":"Abujalala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-8-20240902","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1093\/eurheartj\/ehx391","article-title":"2017 ESC\/EACTS guidelines for the management of valvular heart disease","volume":"38","author":"Baumgartner","year":"2017","journal-title":"Eur Heart J"},{"key":"R2-8-20240902","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1002\/ccd.26541","article-title":"A case of anomalous left coronary artery obstruction caused by lotus valve implantation","volume":"90","author":"Mizote","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"R3-8-20240902","doi-asserted-by":"crossref","first-page":"2317","DOI":"10.1016\/j.jacc.2012.02.022","article-title":"Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies","volume":"59","author":"G\u00e9n\u00e9reux","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"R4-8-20240902","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1002\/ccd.27425","article-title":"A cardiologist's nightmare: Coronary obstruction during transcatheter aortic valve implantation: How to identify patients at highest risk for this complication","volume":"90","author":"Shatila","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"R5-8-20240902","doi-asserted-by":"crossref","first-page":"103","DOI":"10.15420\/ICR.2015.10.2.103","article-title":"Balloon- or self-expandable TAVI: Clinical equipoise?","volume":"10","author":"Jose","year":"2015","journal-title":"Interv Cardiol"},{"key":"R6-8-20240902","doi-asserted-by":"crossref","first-page":"e013801","DOI":"10.1161\/JAHA.119.013801","article-title":"Impact of complications during transfemoral transcatheter aortic valve replacement: How can they be avoided and managed?","volume":"8","author":"Scarsini","year":"2019","journal-title":"J Am Heart Assoc"},{"key":"R7-8-20240902","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1038\/nrcardio.2013.156","article-title":"Mechanisms and management of TAVR-related complications","volume":"10","author":"Fassa","year":"2013","journal-title":"Nat Rev Cardiol"},{"key":"R8-8-20240902","first-page":"e1951","article-title":"A case of acute left main coronary obstruction following transcatheter aortic valve implantation","volume":"9","author":"Dimitrova","year":"2017","journal-title":"Cureus"},{"key":"R9-8-20240902","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1016\/j.jacc.2013.07.040","article-title":"Predictive factors, management, and clinical outcomes of coronary obstruction following transcatheter aortic valve implantation: Insights from a large multicenter registry","volume":"62","author":"Ribeiro","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"R10-8-20240902","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.jcin.2020.02.005","article-title":"Alignment of Transcatheter Aortic-Valve Neo-Commissures (ALIGN TAVR): Impact on final valve orientation and coronary artery overlap","volume":"13","author":"Tang","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"R11-8-20240902","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","article-title":"2021 ESC\/EACTS Guidelines for the management of valvular heart disease","volume":"43","author":"Vahanian","year":"2022","journal-title":"Eur Heart J"},{"key":"R12-8-20240902","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1093\/ehjci\/jew043","article-title":"The use of imaging in new transcatheter interventions: An EACVI review paper","volume":"17","author":"Zamorano","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"R13-8-20240902","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","article-title":"SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR)","volume":"6","author":"Achenbach","year":"2012","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R14-8-20240902","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.jcin.2021.03.028","article-title":"Is BASILICA the standard for preventing coronary obstruction in high-risk transcatheter aortic valve replacement?","volume":"14","author":"De Backer","year":"2021","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Heart Views"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/heartviews.heartviews_27_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:53:54Z","timestamp":1787756034000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/heartviews.heartviews_27_22"}},"subtitle":["Early Recognition Have Better Outcome"],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/heartviews.heartviews_27_22","relation":{},"ISSN":["1995-705X"],"issn-type":[{"value":"1995-705X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}