{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T19:38:52Z","timestamp":1789501132369,"version":"build-2803163510"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>The incorporation of artificial intelligence (AI) in point-of-care ultrasound (POCUS) has become a very useful tool to quickly assess cardiorespiratory function in coronavirus disease (COVID)-19 patients. The objective of this study was to test the agreement between manual and automated B-lines counting, left ventricular outflow tract velocity time integral (LVOT-VTI) and inferior vena cava collapsibility index (IVC-CI) in suspected or confirmed COVID-19 patients using AI integrated POCUS. In addition, we investigated the inter-observer, intra-observer variability and reliability of assessment of echocardiographic parameters using AI by a novice.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Two experienced sonographers in POCUS and one novice learner independently and consecutively performed ultrasound assessment of B-lines counting, LVOT-VTI and IVC-CI in 83 suspected and confirmed COVID-19 cases which included both manual and AI methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Agreement between automated and manual assessment of LVOT-VTI, and IVC-CI were excellent [intraclass correlation coefficient (ICC) 0.98,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001]. Intra-observer reliability and inter-observer reliability of these parameters were excellent [ICC 0.96-0.99,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001]. Moreover, agreement between novice and experts using AI for LVOT-VTI and IVC-CI assessment was also excellent [ICC 0.95-0.97,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001]. However, correlation and intra-observer reliability between automated and manual B-lines counting was moderate [(ICC) 0.52-0.53,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001] and [ICC 0.56-0.69,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001], respectively. Inter-observer reliability was good [ICC 0.79-0.87,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001]. Agreement of B-lines counting between novice and experts using AI was weak [ICC 0.18,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001].\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>AI-guided assessment of LVOT-VTI, IVC-CI and B-lines counting is reliable and consistent with manual assessment in COVID-19 patients. Novices can reliably estimate LVOT-VTI and IVC-CI using AI software in COVID-19 patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ija.ija_1008_21","type":"journal-article","created":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T23:52:41Z","timestamp":1652831561000},"page":"368-374","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":16,"title":["Automated versus manual B-lines counting, left ventricular outflow tract velocity time integral and inferior vena cava collapsibility index in COVID-19 patients"],"prefix":"10.4103","volume":"66","author":[{"given":"Srinath","family":"Damodaran","sequence":"first","affiliation":[{"name":"Department of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anuja Vijay","family":"Kulkarni","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vikneswaran","family":"Gunaseelan","sequence":"additional","affiliation":[{"name":"Department of Clinical Research, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vimal","family":"Raj","sequence":"additional","affiliation":[{"name":"Department of Radiology, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muralidhar","family":"Kanchi","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,5,19]]},"reference":[{"key":"B1-20240902","doi-asserted-by":"crossref","first-page":"1648","DOI":"10.1161\/CIRCULATIONAHA.120.046941","article-title":"Coronavirus Disease 2019 (COVID-19) and cardiovascular disease","volume":"141","author":"Clerkin","year":"2020","journal-title":"Circulation"},{"key":"B3-20240902","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1016\/S0140-6736(20)30566-3","article-title":"Clinical course and risk factors for mortality of adult in patients with COVID-19 in Wuhan, China:A retrospective cohort study","volume":"395","author":"Zhou","year":"2020","journal-title":"Lancet"},{"key":"B4-20240902","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1111\/j.1365-2362.2009.02153.x","article-title":"SARS coronavirus modulation of myocardial ACE2 expression and inflammation in patients with SARS","volume":"39","author":"Oudit","year":"2009","journal-title":"Eur J Clin Invest"},{"key":"B5-20240902","doi-asserted-by":"crossref","first-page":"1740","DOI":"10.1007\/s00134-004-2259-8","article-title":"Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients","volume":"30","author":"Barbier","year":"2004","journal-title":"Intensive Care Med"},{"key":"B6-20240902","doi-asserted-by":"crossref","first-page":"R188","DOI":"10.1186\/cc11672","article-title":"Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure:Need for a cautious use","volume":"16","author":"Muller","year":"2012","journal-title":"Crit Care"},{"key":"B7-20240902","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1186\/s13613-018-0427-1","article-title":"Respiratory changes of the inferior vena cava diameter predict fluid responsiveness in spontaneously breathing patients with cardiac arrhythmias","volume":"8","author":"Bortolotti","year":"2018","journal-title":"Ann Intensive Care"},{"key":"B8-20240902","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1002\/ajum.12205","article-title":"Prevention of pathogen transmission during ultrasound use in the Intensive Care Unit:Recommendations from the College of Intensive Care Medicine Ultrasound Special Interest Group (USIG)","volume":"23","author":"Costello","year":"2020","journal-title":"Australasian J Ultrasound Med"},{"key":"B10-20240902","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1007\/s00246-017-1630-9","article-title":"LVOT-VTI is a useful indicator of low ventricular function in young patients","volume":"38","author":"Navaratnam","year":"2017","journal-title":"Pediatr Cardiol"},{"key":"B11-20240902","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/SHK.0000000000001273","article-title":"A new echocardiographic tool for cardiac output evaluation:An experimental study","volume":"52","author":"Bobbia","year":"2019","journal-title":"Shock"},{"key":"B12-20240902","first-page":"A1775","article-title":"Measuring the accuracy of cardiac output using POCUS:The introduction of artificial intelligence into routine care","volume":"201","author":"Shaikh","year":"2020","journal-title":"Am J Respir Crit Care Med"},{"key":"B13-20240902","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s13089-020-00170-x","article-title":"Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings","volume":"12","author":"Blanco","year":"2020","journal-title":"Ultrasound J"},{"key":"B14-20240902","journal-title":"Venue Go R2 Technical Product Claims Document (DOC2199650)"},{"key":"B15-20240902","doi-asserted-by":"crossref","first-page":"45","DOI":"10.11152\/mu-1885","article-title":"Visual versus automatic ultrasound scoring of lung B-lines:Reliability and consistency between systems","volume":"21","author":"Short","year":"2019","journal-title":"Med Ultrason"},{"key":"B16-20240902","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1186\/s13054-019-2569-4","article-title":"Quantitative lung ultrasonography:A putative new algorithm for automatic detection and quantification of B-lines","volume":"23","author":"Brusasco","year":"2019","journal-title":"Crit Care"},{"key":"B17-20240902","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1136\/heartjnl-2015-307798","article-title":"Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study","volume":"102","author":"Gundersen","year":"2016","journal-title":"Heart"},{"key":"B18-20240902","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1186\/1472-6920-14-156","article-title":"Feasibility and accuracy of point-of-care pocket-size ultrasonography performed by medical students","volume":"14","author":"Andersen","year":"2014","journal-title":"BMC Med Educ"},{"key":"B19-20240902","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.echo.2013.12.006","article-title":"Development and evaluation of methodologies for teaching focused cardiac ultrasound skills to medical students","volume":"27","author":"Cawthorn","year":"2014","journal-title":"J Am Soc Echocardiogr"},{"key":"B20-20240902","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/s13089-021-00234-6","article-title":"B-line quantification:Comparing learner's novice to lung ultrasound assisted by machine artificial intelligence technology to expert review","volume":"13","author":"Russell","year":"2021","journal-title":"Ultrasound J"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_1008_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:54:44Z","timestamp":1787756084000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_1008_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ija.ija_1008_21","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"2021-11-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-04-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}