{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:37:53Z","timestamp":1786739873089,"version":"build-2736575974"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>\n                      While performing laryngoscopy during nasotracheal intubation (NTI), the tip of the advancing endotracheal tube (ETT) generally lies along the posterior pharyngeal wall. The inflation of the ETT cuff brings it anterior towards the glottis. The present study was planned to compare the intubating conditions for NTI with standard direct Macintosh laryngoscope versus C-MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      video laryngoscope (VL) employing ETT cuff inflation technique.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      This prospective randomised study was carried out on 50 patients, American Society of Anesthesiologists physical status I\u2013II, age 18\u201360 years of either sex with an indication for NTI under general anaesthesia. They were randomly divided into two groups: group VL (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 25): C-MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      VL and group ML (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 25): Macintosh laryngoscope. The primary outcome was to compare the total duration of NTI (T), while the secondary outcomes were to compare the need for cuff inflation or assistance with Magill forceps for successful NTI, the total number of attempts to achieve successful NTI, haemodynamic effects and complications.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      T was significantly higher in group ML than group VL (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). The intubation was successful with cuff inflation in all the patients in group VL, however, six patients of group ML required assistance with Magill forceps (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.022). The haemodynamic parameters were all significantly higher at 3 min in group ML in comparison to group VL.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      The cuff inflation technique when used along with C-MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      VL had more success rate, required lesser time and had minimal postoperative complications in comparison to the Macintosh laryngoscope.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ija.ija_236_21","type":"journal-article","created":{"date-parts":[[2021,9,20]],"date-time":"2021-09-20T04:34:18Z","timestamp":1632112458000},"page":"S104-S109","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["A comparison of intubating conditions for nasotracheal intubation with standard direct Macintosh laryngoscope versus C-MAC\u00ae video laryngoscope employing cuff inflation technique in adult patients"],"prefix":"10.4103","volume":"65","author":[{"given":"Sonia","family":"Kasaudhan","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, Esi Hospital and PGIMSR, Basaidarapur, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhu","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Esi Hospital and PGIMSR, Basaidarapur, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kriti","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Esi Hospital and PGIMSR, Basaidarapur, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anas","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Esi Hospital and PGIMSR, Basaidarapur, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,9,15]]},"reference":[{"key":"-20240902","doi-asserted-by":"crossref","first-page":"662","DOI":"10.4103\/0972-5229.194013","article-title":"Nasal intubation:A comprehensive review","volume":"20","author":"Chauhan","year":"2016","journal-title":"Indian J Crit Care Med"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"732","DOI":"10.4103\/0019-5049.191676","article-title":"Does C- MAC\u00aevideo laryngoscope improve the nasotracheal intubating conditions compared to Macintosh direct laryngoscope in paediatric patients posted for tonsillectomy surgeries?","volume":"60","author":"Patil","year":"2016","journal-title":"Indian J Anaesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"831","DOI":"10.2147\/TCRM.S136221","article-title":"Current evidence for the use of C-MAC videolaryngoscope in adult airway management:A review of the literature","volume":"13","author":"Xue","year":"2017","journal-title":"Ther Clin Risk Manag"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1007\/s12630-010-9285-5","article-title":"Cuff inflation as an aid to nasotracheal intubation using the Airtraq\u00ae laryngoscope","volume":"57","author":"Xue","year":"2010","journal-title":"Can J Anesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"340","DOI":"10.4103\/mjdrdypu.mjdrdypu_149_18","article-title":"Effect of cuff inflation technique in video laryngoscopic assisted nasal intubation in oral cancer surgeries","volume":"12","author":"Shah","year":"2019","journal-title":"Med J DY Patil Vidyapeeth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"369","DOI":"10.4103\/ija.IJA_1393_20","article-title":"Comparison of cuff inflation method with curvature control modification in thermosoftened endotracheal tubes during nasotracheal intubation \u2013A prospective randomised controlled study","volume":"65","author":"Prashant","year":"2021","journal-title":"Indian J Anaesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"381","DOI":"10.4103\/joacp.JOACP_296_17","article-title":"Ease of intubation and hemodynamic responses to nasotracheal intubation using C-MAC videolaryngoscope with D blade:A comparison with use of traditional Macintosh laryngoscope","volume":"34","author":"Rajan","year":"2018","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1007\/s12630-017-0971-4","article-title":"Randomized comparison of the effectiveness of nasal intubation using a GlideScope video laryngoscope with Magill forceps versus vascular forceps in patients with a normal airway","volume":"64","author":"Yeom","year":"2017","journal-title":"Can J Anesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1213\/ane.0b013e31816d15c9","article-title":"A comparison of GlideScope\u00aevideolaryngoscopy to direct laryngoscopy for nasotracheal intubation","volume":"107","author":"Jones","year":"2008","journal-title":"Anesth Analg"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1111\/j.1365-2044.2011.06872.x","article-title":"Performance of the C-MAC\u00aevideo laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy","volume":"66","author":"Piepho","year":"2011","journal-title":"Anaesthesia"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"253","DOI":"10.4103\/ija.IJA_631_20","article-title":"Awake intubation with C-MAC videolaryngoscope in a patient with difficult airway","volume":"65","author":"Vaishnavi","year":"2021","journal-title":"Indian J Anaesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"133","DOI":"10.4103\/ija.IJA_1218_20","article-title":"Comparison of aerosol box intubation with C-MAC video laryngoscope and direct laryngoscopy\u2014A randomised controlled trial","volume":"65","author":"Puthenveettil","year":"2021","journal-title":"Indian J Anaesth"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1213\/ANE.0b013e31827e4d19","article-title":"Cuff inflation-supplemented laryngoscope-guided nasal intubation:A comparison of three endotracheal tubes","volume":"116","author":"Kumar","year":"2013","journal-title":"Anesth Analg"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1213\/00000539-200009000-00038","article-title":"Thermosoftening treatment of the nasotracheal tube before intubation can reduce epistaxis and nasal damage","volume":"91","author":"Kim","year":"2000","journal-title":"Anesth Analg"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"1488","DOI":"10.1213\/01.ANE.0000082244.93210.2F","article-title":"A silicone-based wire-reinforced tracheal tube with a hemispherical bevel reduces nasal morbidity for nasotracheal intubation","volume":"97","author":"Kihara","year":"2003","journal-title":"Anesth Analg"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1007\/BF03021066","article-title":"Blind nasotracheal intubation is facilitated by neutral head position and endotracheal tube cuff inflation in spontaneously breathing patients","volume":"50","author":"Chung","year":"2003","journal-title":"Can J Anesth"},{"key":"-20240902","first-page":"84","article-title":"Cuff inflation to aid Nasotracheal intubation using the C-MAC videolaryngoscope","volume":"46","author":"Baddoo","year":"2011","journal-title":"Ghana Med J"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.joms.2015.07.021","article-title":"McGrath Video laryngoscopy facilitates routine nasotracheal intubation in patients undergoing oral and maxillofacial surgery:A comparison with Macintosh laryngoscopy","volume":"74","author":"Kwak","year":"2016","journal-title":"J Oral Maxillofac Surg"},{"key":"-20240902","doi-asserted-by":"crossref","first-page":"e2514","DOI":"10.1097\/MD.0000000000002514","article-title":"Comparison of McGrath series 3 and Macintosh laryngoscopes for tracheal intubation in patients with normal airway by inexperienced anesthetists:A randomized study","volume":"95","author":"Liu","year":"2016","journal-title":"Medicine (Baltimore)"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.IJA_236_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:35:08Z","timestamp":1786736108000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.IJA_236_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9]]},"references-count":19,"journal-issue":{"issue":"Suppl 3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/ija.ija_236_21","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9]]},"assertion":[{"value":"2021-04-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-20","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}