{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:21:23Z","timestamp":1787772083388,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>Accurate blood pressure monitoring is crucial in the beach-chair position (BCP), which poses a risk of cerebral hypoperfusion. This study compared arm and ankle non-invasive blood pressure (NIBP) with invasive arterial blood pressure (IBP) for detecting hypotension.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective observational study included 36 adults undergoing shoulder surgery in the BCP after obtaining written informed consent. The primary objective was to evaluate the diagnostic performance of arm and ankle NIBP in detecting hypotension at IBP. Secondary objectives assessed agreement with IBP using Bland\u2013Altman analysis (BAA) and clinical risk using error grid analysis (EGA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 1088 paired NIBP\u2013IBP readings were analysed, of which 326 were hypotensive. Arm mean arterial pressure (MAP) identified hypotension more accurately than ankle MAP, with a higher area under the curve of 0.83, 95% confidence interval (CI) 0.81\u20130.86 versus 0.72, 95% CI 0.70\u20130.76,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001. At arm, an MAP threshold of 75 mm of Hg could detect hypotension with 77% sensitivity, 76% specificity, and 77% overall accuracy. At the ankle, a threshold of 76 mmHg had 62% sensitivity, 72% specificity, and 69% accuracy. BAA showed that both arm and ankle NIBP overestimated invasive MAP, with a bias of + 4.6 mmHg for the arm (95% limits of agreement: \u221237.9 to + 47.2) and + 5.9 mmHg for the ankle (95% limits of agreement: \u221210.4 to + 22). On EGA, 83% of arm readings and 75% of ankle readings were in Zone A, whereas high-risk errors in Zones D\u2013E were more common with ankle measurements than with arm measurements (5.4% vs 3.6%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In the beach-chair position, both ankle and arm NIBP are unreliable for detecting hypotension and invasive arterial monitoring should be preferred when accurate blood pressure assessment is vital.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ija.ija_251_26","type":"journal-article","created":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T12:04:58Z","timestamp":1781697898000},"page":"741-748","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of ankle versus arm oscillometric non-invasive blood pressure in detecting hypotension during shoulder surgery in the beach-chair position: A prospective observational study"],"prefix":"10.4103","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6707-4627","authenticated-orcid":false,"given":"Aparajita","family":"Panda","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9766-5683","authenticated-orcid":false,"given":"Reshmitha","family":"Boyana","sequence":"additional","affiliation":[{"name":"Department of Trauma and Emergency, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3558-2755","authenticated-orcid":false,"given":"Nitasha","family":"Mishra","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8513-7895","authenticated-orcid":false,"given":"Saroj Kumar","family":"Patra","sequence":"additional","affiliation":[{"name":"Department of Trauma and Emergency, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9497-9624","authenticated-orcid":false,"given":"Bishnu P.","family":"Patro","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0663-0922","authenticated-orcid":false,"given":"Anand","family":"Srinivasan","sequence":"additional","affiliation":[{"name":"Department of Pharmacology, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,18]]},"reference":[{"key":"R1-20260617","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1213\/ANE.0000000000004133","article-title":"Safety of beach chair position shoulder surgery: A review of the current literature","volume":"129","author":"Murphy","year":"2019","journal-title":"Anesth Analg"},{"key":"R2-20260617","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1007\/s00402-023-05109-0","article-title":"Postoperative cognitive dysfunction after beach chair positioning compared to supine position in orthopaedic surgery in the elderly","volume":"144","author":"Groene","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"R3-20260617","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.jclinane.2018.09.035","article-title":"The beach chair position for shoulder surgery in intravenous general anaesthesia and controlled hypotension: Impact on cerebral oxygenation, cerebral blood flow and neurobehavioral outcome","volume":"53","author":"Aguirre","year":"2019","journal-title":"J Clin Anesth"},{"key":"R4-20260617","first-page":"E63","article-title":"Neurocognitive deficits and cerebral desaturation during shoulder arthroscopy with patient in beach-chair position: A review of the current literature","volume":"45","author":"Salazar","year":"2016","journal-title":"Am J Orthop"},{"key":"R5-20260617","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jclinane.2016.01.009","article-title":"Middle cerebral artery blood flow velocity during beach chair position for shoulder surgery under general anaesthesia","volume":"33","author":"Hanouz","year":"2016","journal-title":"J Clin Anesth"},{"key":"R6-20260617","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1007\/s10877-018-0211-7","article-title":"Cerebrovascular assessment of patients undergoing shoulder surgery in beach chair position using a multiparameter transcranial Doppler approach","volume":"33","author":"Cardim","year":"2019","journal-title":"J Clin Monit Comput"},{"key":"R7-20260617","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.jor.2019.05.009","article-title":"Shoulder surgery in beach chair position causing perioperative stroke: Four cases and a review of the literature","volume":"16","author":"van Erp","year":"2019","journal-title":"J Orthop"},{"key":"R8-20260617","first-page":"46","article-title":"APSF workshop: Cerebral perfusion experts share views on management of head-up cases","volume":"24","author":"Lee","year":"2009","journal-title":"APSF Newsl"},{"key":"R9-20260617","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1093\/ajh\/hpae061","article-title":"Size dimension chart for reference cuff validation and limitations in current recommendations","volume":"37","author":"Juraschek","year":"2024","journal-title":"Am J Hypertens"},{"key":"R10-20260617","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1186\/s13054-020-02859-w","article-title":"How to measure blood pressure using an arterial catheter: A systematic 5-step approach","volume":"24","author":"Saugel","year":"2020","journal-title":"Crit Care"},{"key":"R11-20260617","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1186\/s12874-020-01022-x","article-title":"Using multiple agreement methods for continuous repeated measures data: A tutorial for practitioners","volume":"20","author":"Parker","year":"2020","journal-title":"BMC Med Res Methodol"},{"key":"R12-20260617","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1213\/ANE.0000000000002585","article-title":"Error grid analysis for arterial pressure method comparison studies","volume":"126","author":"Saugel","year":"2018","journal-title":"Anesth Analg"},{"key":"R13-20260617","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1007\/s10877-020-00583-y","article-title":"Accuracy of noninvasive blood pressure measured at the ankle during cesarean delivery under spinal anaesthesia","volume":"35","author":"Refaat","year":"2021","journal-title":"J Clin Monit Comput"},{"key":"R14-20260617","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1186\/s12871-024-02595-6","article-title":"Accuracy of oscillometric noninvasive blood pressure at the ankle in the lateral position during general anaesthesia","volume":"24","author":"Farag","year":"2024","journal-title":"BMC Anesthesiol"},{"key":"R15-20260617","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1007\/s10877-023-01025-1","article-title":"Evaluation of the accuracy of oscillometric non-invasive blood pressure measurement at the ankle in children during general anaesthesia","volume":"37","author":"Gamal","year":"2023","journal-title":"J Clin Monit Comput"},{"key":"R16-20260617","doi-asserted-by":"crossref","first-page":"515","DOI":"10.4097\/kjae.2012.63.6.515","article-title":"Ankle-brachial blood pressure differences in the beach-chair position of the shoulder surgery","volume":"63","author":"Choi","year":"2012","journal-title":"Korean J Anesthesiol"},{"key":"R17-20260617","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jse.2014.05.011","article-title":"Association between temporal mean arterial pressure and brachial noninvasive blood pressure during shoulder surgery in the beach chair position during general anesthesia","volume":"24","author":"Triplet","year":"2015","journal-title":"J Shoulder Elbow Surg"},{"key":"R18-20260617","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.chest.2024.08.042","article-title":"Noninvasive arterial pressure measurements at the lower leg: Evaluation of the influence of patient position (semi-recumbent or horizontal) \u2013 A prospective study","volume":"167","author":"Lakhal","year":"2025","journal-title":"Chest"},{"key":"R19-20260617","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1097\/HJH.0000000000001634","article-title":"A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation\/European Society of Hypertension\/International Organization for Standardization (AAMI\/ESH\/ISO) Collaboration Statement","volume":"36","author":"Stergiou","year":"2018","journal-title":"J Hypertens"},{"key":"R20-20260617","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1186\/s12871-020-01185-6","article-title":"Non-invasive continuous blood pressure monitoring (ClearSight\u2122system) during shoulder surgery in the beach chair position: A prospective self-controlled study","volume":"20","author":"Chachula","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"R21-20260617","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1007\/s10877-016-9939-0","article-title":"Patterns of intra-arterial blood pressure monitoring for patients undergoing total shoulder arthroplasty under general anaesthesia: A retrospective analysis of 23,073 patients","volume":"31","author":"Gabriel","year":"2017","journal-title":"J Clin Monit Comput"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_251_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T18:28:38Z","timestamp":1787768918000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_251_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ija.ija_251_26","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"2026-02-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}