{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:23:44Z","timestamp":1787757824192,"version":"build-2784847793"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>\n                      Video laryngoscopy highly improves the success rate for endotracheal intubation. However, commercially available video laryngoscopes such as McGrath MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      can be costly. An economical video laryngoscope was assembled by attaching a fibreoptic videoscope into a Macintosh laryngoscope. This randomised study aimed to compare the intubation time of this self-assembled modified Macintosh video laryngoscope (SAM-VL) and McGrath MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      (McGrath).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study enroled 62 adults scheduled for elective surgery under general anaesthesia with endotracheal intubation. The primary outcome was total intubation time. Secondary outcomes were the time for glottic visualisation (time A), time for tube insertion after glottic visualisation (time B), first-attempt intubation success rate, degree of glottic visualisation, and need for backward, upward, rightward pressure (BURP) assistance, complications, and user satisfaction. The tests used were: Kolmogorov-Smirnov and the Mann-Whitney test to analyse the data\u2019s distribution and the primary outcome, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The median total intubation time in the SAM-VL group versus the McGrath was 63 s (27\u2013114s) versus 74 s (40\u2013133s), respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.032). Intubation time B was significantly faster, while the score of glottic visualisation and BURP assistance was significantly higher in the SAM-VL group. The differences in the rate of successful first attempts and complications were not statistically significant. SAM-VL users rated the ease of blade insertion and manoeuvrability, degree of glottic visualisation, and overall rating as very high.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      Endotracheal intubation using self-assembled modified video laryngoscope is faster and allows better glottis visualisation than McGrath MAC\n                      <jats:sup>\u00ae<\/jats:sup>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ija.ija_300_21","type":"journal-article","created":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T23:52:41Z","timestamp":1652831561000},"page":"350-357","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of self-assembled video laryngoscope versus McGrath MAC\u00ae: A randomised controlled trial"],"prefix":"10.4103","volume":"66","author":[{"given":"Besthadi","family":"Sukmono","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia \u2013 Cipto Mangunkusumo Hospital, Jalan Diponegoro No. 71, Jakarta, 10430, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sidharta K.","family":"Manggala","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia \u2013 Cipto Mangunkusumo Hospital, Jalan Diponegoro No. 71, Jakarta, 10430, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aino N.","family":"Auerkari","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia \u2013 Cipto Mangunkusumo Hospital, Jalan Diponegoro No. 71, Jakarta, 10430, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Budiani","family":"Christina","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia \u2013 Cipto Mangunkusumo Hospital, Jalan Diponegoro No. 71, Jakarta, 10430, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,5,19]]},"reference":[{"key":"B2-20240902","doi-asserted-by":"crossref","first-page":"8943931","DOI":"10.1155\/2016\/8943931","article-title":"Comparing McGrath MAC, C-MAC, and Macintosh laryngoscopes operated by medical students:A randomized, crossover, manikin study","volume":"2016","author":"Shin","year":"2016","journal-title":"Biomed Res Int"},{"key":"B3-20240902","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1111\/anae.13209","article-title":"A comparison of the ease of tracheal intubation using a McGrath MAC laryngoscope and a standard Macintosh laryngoscope","volume":"70","author":"Wallace","year":"2015","journal-title":"Anaesthesia"},{"key":"B4-20240902","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.tacc.2018.02.003","article-title":"Use of the McGRATH\u2122MAC:To view or not to view?","volume":"19","author":"Normand","year":"2018","journal-title":"Trends Anaesth Crit Care"},{"key":"B5-20240902","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.annemergmed.2010.05.035","article-title":"The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices","volume":"57","author":"Levitan","year":"2011","journal-title":"Ann Emerg Med"},{"key":"B6-20240902","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1093\/bja\/aes145","article-title":"Randomized controlled trial comparing the McGrath video laryngoscope with the C-MAC video laryngoscope in intubating adult patients with potential difficult airways","volume":"109","author":"Ng","year":"2012","journal-title":"Br J Anaesth"},{"key":"B7-20240902","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jclinane.2017.12.030","article-title":"McGrath video laryngoscope versus Macintosh laryngoscope for tracheal intubation:A systematic review and meta-analysis with trial sequential analysis","volume":"46","author":"Hoshijima","year":"2018","journal-title":"J Clin Anesth"},{"key":"B8-20240902","first-page":"45","article-title":"Comparison between custom made video laryngoscope and Macintosh laryngoscope aided endotracheal intubation:A simple and inexpensive digital tool","volume":"16","author":"Luqmanmuhamed","year":"2017","journal-title":"IOSR J Dent Med Sci"},{"key":"B9-20240902","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/00000542-200301000-00008","article-title":"Optimal oxygen concentration during induction of general anesthesia","volume":"98","author":"Edmark","year":"2003","journal-title":"Anesthesiology"},{"key":"B10-20240902","first-page":"1","article-title":"Videolaryngoscopy in airway management:What every anesthesiologist should know","volume":"4","author":"Xue","year":"2017","journal-title":"J Anesth Perioper Med"},{"key":"B12-20240902","doi-asserted-by":"crossref","first-page":"27","DOI":"10.15851\/jap.v6n1.1287","article-title":"Perbandingan intubasi endotrakea menggunakan clip-on smartphone camera video laryngoscope dengan laringoskop Macintosh pada manekin","volume":"6","author":"Latuconsina","year":"2018","journal-title":"Jurnal Anestesi Perioperatif"},{"key":"B13-20240902","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1111\/aas.13043","article-title":"A comparison between McGrath MAC videolaryngoscopy and Macintosh laryngoscopy in children","volume":"62","author":"Kim","year":"2018","journal-title":"Acta Anaesthesiol Scand"},{"key":"B14-20240902","doi-asserted-by":"crossref","first-page":"456","DOI":"10.4103\/ija.IJA_48_19","article-title":"McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes:A randomised control trial","volume":"63","author":"Bakshi","year":"2019","journal-title":"Indian J Anaesth"},{"key":"B15-20240902","doi-asserted-by":"crossref","first-page":"e8713","DOI":"10.1097\/MD.0000000000008713","article-title":"Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway","volume":"96","author":"Lee","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"B16-20240902","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s10877-015-9727-2","article-title":"The comparison of the technical parameters in endotracheal intubation devices:The Cmac, the Vividtrac, the McGrath Mac and the Kingvision","volume":"30","author":"Cierniak","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"B17-20240902","doi-asserted-by":"crossref","first-page":"321","DOI":"10.4103\/ija.IJA_417_20","article-title":"Haemodynamic responses following orotracheal intubation in patients with hypertension---Macintosh direct laryngoscope versus Glidescope\u00aevideolaryngoscope","volume":"65","author":"Meshram","year":"2021","journal-title":"Indian J Anaesth"},{"key":"B18-20240902","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.bja.2017.12.041","article-title":"Videolaryngoscopy versus direct laryngoscopy for emergency orotracheal intubation outside the operating room:A systematic review and meta-analysis","volume":"120","author":"Arulkumaran","year":"2018","journal-title":"Br J Anaesth"},{"key":"B19-20240902","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1111\/j.1365-2044.2009.06061.x","article-title":"A comparison of McGrath and Macintosh laryngoscopes in novice users:A manikin study","volume":"64","author":"Ray","year":"2009","journal-title":"Anaesthesia"},{"key":"B20-20240902","doi-asserted-by":"crossref","first-page":"187","DOI":"10.4103\/ija.ija_832_21","article-title":"Comparison between C-MAC and King Vision video laryngoscope (channelled blade) for tracheal intubation in aerosol-prevention intubation box for COVID-19 patients:A manikin-based study","volume":"66","author":"Kumar","year":"2022","journal-title":"Indian J Anaesth"},{"key":"B21-20240902","doi-asserted-by":"crossref","first-page":"169","DOI":"10.4103\/ija.ija_234_22","article-title":"Videolaryngoscopy for all intubations:Is direct laryngoscopy obsolete?","volume":"66","author":"Myatra","year":"2022","journal-title":"Indian J Anaesth"},{"key":"B22-20240902","doi-asserted-by":"crossref","first-page":"221","DOI":"10.4103\/ija.IJA_1578_20","article-title":"Intubation outcomes using the aerosol box during the COVID-19 pandemic:A prospective, observational study","volume":"65","author":"Venketeswaran","year":"2021","journal-title":"Indian J Anaesth"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_300_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:53:58Z","timestamp":1787756038000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_300_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ija.ija_300_21","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"2021-04-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-04-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}