{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:34:09Z","timestamp":1787762049024,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>A variety of extraglottic airway devices (EADs) are available. Main concerns with EADs are protection against aspiration and ability to ventilate patients with high airway pressures. Baska mask meets these criteria and is the only third-generation device available for clinical use.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>After institutional ethics committee approval and informed consent were obtained, this prospective study was performed in 100 adult patients undergoing surface surgeries at a tertiary referral centre. The primary outcome was the success rate of insertion, while the secondary outcomes were the sealing pressure, stability of the device and the perioperative complications of Baska mask. We then compared it with other currently used EADs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The first attempt at insertion and overall success rates, showed values of 81% and 98%, respectively. Insertion was quick (median 12; interquartile range [IQR] 9\u201315 s). The mask sealing pressure, was 35 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O (median [IQR 20\u201350 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O]). Also, the mask remained stable in 95% of patients intraoperatively. Sore throat and dysphagia were seen in 37% and 24% of patients, respectively. No patient had laryngospasm or desaturation at any time. It compared favourably well with other EADs, while achieving higher sealing pressures.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>We found that the Baska mask performs well with excellent first attempt at insertion and overall success rates, higher sealing pressures and minimal complications compared to currently used EADs in clinical anaesthesia.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ija.ija_997_21","type":"journal-article","created":{"date-parts":[[2023,7,15]],"date-time":"2023-07-15T13:06:13Z","timestamp":1689426373000},"page":"603-608","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Does Baska mask deserve its own niche among extraglottic airway devices? A prospective, single-arm study"],"prefix":"10.4103","volume":"67","author":[{"given":"Vinisha","family":"Shah","sequence":"first","affiliation":[{"name":"Department of Anaesthesia, NH-SRCC Children\u2019s Hospital, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kailash S.","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, Critical Care and Pain, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atul P.","family":"Kulkarni","sequence":"additional","affiliation":[{"name":"Division of Critical Care Medicine, Department of Anaesthesia, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7,14]]},"reference":[{"key":"R1-20240902","doi-asserted-by":"crossref","first-page":"87","DOI":"10.14712\/23362936.2014.40","article-title":"Airway management evolution-in a search for an ideal extraglottic airway device","volume":"115","author":"Mich\u00e1lek","year":"2014","journal-title":"Prague Med Rep"},{"key":"R2-20240902","doi-asserted-by":"crossref","first-page":"23","DOI":"10.4103\/2249-4472.99313","article-title":"The Baska Mask\u00ae-A new concept in Self-sealing membrane cuff extraglottic airway devices, using a sump and two gastric drains: A critical evaluation","volume":"2","author":"van Zundert","year":"2012","journal-title":"J Obstet Anaesth Crit Care"},{"key":"R3-20240902","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1111\/j.1365-2044.2012.07140.x","article-title":"An observational study of the Baska\u00aemask: A novel supraglottic airway","volume":"67","author":"Alexiev","year":"2012","journal-title":"Anaesthesia"},{"key":"R4-20240902","first-page":"74","article-title":"Evaluation of Baska mask performance in laparoscopic cholecystectomy","volume":"17","author":"Mahajan","year":"2018","journal-title":"IOSR J Dent Med Sci"},{"key":"R5-20240902","first-page":"29","article-title":"Comparison of I-gel with Baska mask airway for controlled ventilation in obese patients undergoing ambulatory surgery: A prospective randomized trial","volume":"5","author":"Aziz","year":"2017","journal-title":"Int J Anesth Clin Med"},{"key":"R6-20240902","doi-asserted-by":"crossref","first-page":"419","DOI":"10.4103\/joacp.JOACP_339_19","article-title":"Efficacy of Baska mask as an alternative airway device to endotracheal tube in patients undergoing laparoscopic surgeries under controlled ventilation","volume":"37","author":"Tosh","year":"2021","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R7-20240902","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1177\/0310057X1003800322","article-title":"An evaluation of the Laryngeal Mask Airway SupremeTM in 100 patients","volume":"38","author":"Tan","year":"2010","journal-title":"Anaesth Intensive Care"},{"key":"R8-20240902","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1097\/ALN.0b013e31819b5d40","article-title":"Comparison of two insertion techniques of prosealTM laryngeal mask airway: Standard versus 90-degree rotation","volume":"110","author":"Hwang","year":"2009","journal-title":"Anesthesiology"},{"key":"R9-20240902","first-page":"52","article-title":"A preliminary study of I-gel: A new supraglottic airway device","volume":"53","author":"Kannaujia","year":"2009","journal-title":"Indian J Anaesth"},{"key":"R10-20240902","doi-asserted-by":"crossref","first-page":"e64427","DOI":"10.5812\/aapm.64427","article-title":"The determination of an appropriate time for placement of the classic laryngeal mask airway in patients undergoing general anesthesia","volume":"8","author":"Abedini","year":"2018","journal-title":"Anesthesiol Pain Med"},{"key":"R11-20240902","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1186\/s12871-019-0773-z","article-title":"Comparison of standard versus 90\u00b0rotation technique for LMA FlexibleTM insertion: A randomized controlled trial","volume":"19","author":"Koo","year":"2019","journal-title":"BMC Anesthesiol"},{"key":"R12-20240902","doi-asserted-by":"crossref","first-page":"302","DOI":"10.5144\/0256-4947.2019.302","article-title":"Comparison of the Baska and I-gel supraglottic airway devices: A randomized controlled study","volume":"39","author":"Kara","year":"2019","journal-title":"Ann Saudi Med"},{"key":"R13-20240902","first-page":"406","article-title":"Comparison of the supraglottic airway devices classic, Fastrach and supreme laryngeal mask airway: A prospective randomised clinical trial of efficacy, safety and complications","volume":"43","author":"K\u00f6m\u00fcr","year":"2015","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"R14-20240902","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.bjan.2017.04.007","article-title":"Comparison of three different insertion techniques with LMA-UniqueTM in adults: Results of a randomized trial","volume":"67","author":"Eglen","year":"2017","journal-title":"Rev Bras Anestesiol"},{"key":"R15-20240902","doi-asserted-by":"crossref","first-page":"69","DOI":"10.4103\/ami.ami_41_18","article-title":"A comparative analysis of the baska mask versus I-gel for general anesthesia in surgical patients undergoing laparoscopic cholecystectomy","volume":"5","author":"Chaudhary","year":"2018","journal-title":"Acta Medica Int"},{"key":"R16-20240902","first-page":"CD009026","article-title":"ProSeal versus Classic laryngeal mask airway (LMA) for positive pressure ventilation in adults undergoing elective surgery","volume":"7","author":"Hoda","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"R17-20240902","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1017\/S0265021506001219","article-title":"Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures","volume":"24","author":"Francksen","year":"2007","journal-title":"Eur J Anaesthesiol"},{"key":"R18-20240902","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1111\/anae.12917","article-title":"Cranial nerve injuries with supraglottic airway devices: A systematic review of published case reports and series","volume":"70","author":"Thiruvenkatarajan","year":"2015","journal-title":"Anaesthesia"},{"key":"R19-20240902","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1093\/bja\/aei187","article-title":"Lingual nerve injury associated with the ProSeal laryngeal mask airway: A case report and review of the literature","volume":"95","author":"Brimacombe","year":"2005","journal-title":"Br J Anaesth"},{"key":"R20-20240902","first-page":"233","article-title":"A comparative analysis of the Baska\u00aemask vs. Proseal\u00aelaryngeal mask for general anesthesia with IPPV","volume":"17","author":"Al-Rawahi","year":"2013","journal-title":"Anaesth Pain Intensive Care"},{"key":"R21-20240902","first-page":"746560","article-title":"Complications associated with the use of supraglottic airway devices in perioperative medicine","author":"Michalek","year":"2015","journal-title":"Biomed Res Int 2015"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_997_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:15:17Z","timestamp":1787760917000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ija.ija_997_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":21,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/ija.ija_997_21","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"2021-11-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-03-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}