{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T12:28:23Z","timestamp":1787228903517,"version":"build-2736575974"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Left bundle branch pacing (LBBP) is developing as an effective technique for cardiac pacing, offering potential advantages over traditional right ventricular pacing methods. However, comprehensive assessment of LBBP outcomes across various indications and over extended follow-up periods is limited. This single-center prospective study aims to address this gap by evaluating the electrophysiological, echocardiographic, and clinical outcomes of LBBP over a 12-month follow-up period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This was a single-center prospective cohort study with repeated follow-up assessments performed at 3, 6, and 12 months following left bundle branch area pacing (LBBAP) implantation. This study enrolled 63 patients aged 18\u201380 with symptomatic bradyarrhythmia and left ventricular dysfunction undergoing LBBAP using Select Secure pacing leads. Outcomes were compared pre- and post-implantation at 3-, 6-, and 12-month follow-up, assessing electrophysiological parameters, cardiac function, and adverse events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In this study, successful implantation was achieved in all patients, with selective LBB capture demonstrated in 78.9%. Lead parameters such as capture threshold, paced QRS duration, pacing impedance, and R wave amplitude at 3, 6, and 12 months when compared with the baseline, remained stable with no significant changes over time. Individuals with lower baseline ejection fraction EF improved significantly from baseline between 3 and 6 months, 6 and 12 months, and 3 and 12 months, respectively. Procedural and late complications were minimal.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>With improvements observed in electrophysiological parameters, cardiac function, and minimal adverse events over a 12-month follow-up period, LBBP demonstrates both efficacy and safety in this patient population. These results advocate for further exploration and utilization of LBBP as a preferred pacing strategy in clinical practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijabmr.ijabmr_94_26","type":"journal-article","created":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:00:54Z","timestamp":1787166054000},"page":"164-170","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Assessment of Clinical Outcomes and Electrophysiological Parameters of Left Bundle Branch Area Pacing: A Single-center Prospective Study with 12-month Follow-up"],"prefix":"10.4103","volume":"16","author":[{"given":"Naved","family":"Aslam","sequence":"first","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anshuman","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bhavuk","family":"Jaiswal","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Fortis Hospital, Faridabad, Haryana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gurpreet Singh","family":"Wander","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shibba Takkar","family":"Chhabra","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhishek","family":"Goyal","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akash","family":"Batta","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bishav","family":"Mohan","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,19]]},"reference":[{"issue":"3","key":"R1-20260820","article-title":"Evolution of cardiac pacemakers: A journey from galvanic experiments to leadless pacemakers","volume":"7","author":"Bakytzhanuly","year":"2023","journal-title":"Heart Vessel Transplant"},{"key":"R2-20260820","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1146\/annurev-med-051022-042616","article-title":"Emerging Technologies in Cardiac Pacing","volume":"75","author":"Vajapey","year":"2024","journal-title":"Annu Rev Med"},{"key":"R3-20260820","doi-asserted-by":"crossref","first-page":"6889","DOI":"10.3390\/jcm11236889","article-title":"Cardiomyopathy associated with right ventricular apical pacing-systematic review and meta-analysis","volume":"11","author":"Osiecki","year":"2022","journal-title":"J Clin Med"},{"key":"R4-20260820","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1136\/heartjnl-2022-321723","article-title":"Pacing induced cardiomyopathy: Recognition and management","volume":"109","author":"Ponnusamy","year":"2023","journal-title":"Heart"},{"key":"R5-20260820","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1007\/s00399-012-0167-0","article-title":"Using devices with a variable postventricular atrial refractory period for cardiac resynchronization","volume":"23","author":"Barold","year":"2012","journal-title":"Herzschrittmacherther Elektrophysiol"},{"key":"R6-20260820","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.hroo.2020.03.002","article-title":"Left bundle branch pacing is the best approach to physiological pacing","volume":"1","author":"Padala","year":"2020","journal-title":"Heart Rhythm O2"},{"key":"R7-20260820","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/j.hrcr.2023.06.015","article-title":"Ventricular tachycardia exacerbated by left bundle branch area pacing","volume":"9","author":"Tanawuttiwat","year":"2023","journal-title":"HeartRhythm Case Rep"},{"key":"R8-20260820","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jacep.2020.08.015","article-title":"Left Bundle Branch Area Pacing for Cardiac Resynchronization Therapy: Results From the International LBBAP Collaborative Study Group","volume":"7","author":"Vijayaraman","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"R9-20260820","doi-asserted-by":"crossref","first-page":"2462","DOI":"10.1111\/jce.14681","article-title":"Left bundle branch pacing: A comprehensive review","volume":"31","author":"Ponnusamy","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R10-20260820","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.hrthm.2019.05.011","article-title":"Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"R11-20260820","doi-asserted-by":"crossref","first-page":"1758","DOI":"10.1016\/j.hrthm.2019.05.014","article-title":"Left bundle branch pacing for symptomatic bradycardia: Implant success rate, safety, and pacing characteristics","volume":"16","author":"Li","year":"2019","journal-title":"Heart Rhythm"},{"key":"R12-20260820","doi-asserted-by":"crossref","first-page":"e008874","DOI":"10.1161\/CIRCEP.120.008874","article-title":"Pros and cons of left bundle branch pacing: A single-center experience","volume":"13","author":"Ravi","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R13-20260820","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.1007\/s10840-022-01463-y","article-title":"Maximizing QRS duration reduction in contemporary cardiac resynchronization therapy is feasible and shorter QRS duration is associated with better clinical outcome","volume":"66","author":"Borgquist","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"R14-20260820","doi-asserted-by":"crossref","first-page":"685253","DOI":"10.3389\/fcvm.2021.685253","article-title":"Clinical outcomes in patients with left bundle branch area pacing versus right ventricular pacing for atrioventricular block","volume":"8","author":"Li","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"R15-20260820","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1002\/clc.23215","article-title":"Immediate clinical outcomes of left bundle branch area pacing versus conventional right ventricular pacing","volume":"42","author":"Zhang","year":"2019","journal-title":"Clin Cardiol"},{"key":"R16-20260820","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1007\/s10840-020-00807-w","article-title":"Mid-term feasibility, safety and outcomes of left bundle branch pacing-single center experience","volume":"60","author":"Ponnusamy","year":"2021","journal-title":"J Interv Card Electrophysiol"},{"key":"R17-20260820","doi-asserted-by":"crossref","first-page":"e003344","DOI":"10.1161\/CIRCEP.115.003344","article-title":"Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum","volume":"9","author":"Mafi-Rad","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R18-20260820","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.jacep.2020.04.011","article-title":"Cardiac resynchronization therapy in patients with nonischemic cardiomyopathy using left bundle branch pacing","volume":"6","author":"Huang","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"R19-20260820","doi-asserted-by":"crossref","first-page":"727611","DOI":"10.3389\/fcvm.2021.727611","article-title":"Mechanical synchrony and myocardial work in heart failure patients with left bundle branch area pacing and comparison with biventricular pacing","volume":"8","author":"Liu","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"R20-20260820","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/s42444-021-00040-0","article-title":"Chronology of cardiac dysfunction after permanent pacemaker implantation: An observational 2 year prospective study in North India","volume":"22","author":"Gupta","year":"2021","journal-title":"Int J Arrhythm"},{"key":"R21-20260820","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1002\/joa3.12610","article-title":"Left bundle branch area pacing: Electrocardiographic features","volume":"37","author":"Das","year":"2021","journal-title":"J Arrhythm"},{"key":"R22-20260820","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1111\/pace.14017","article-title":"Sudden and significant R\u2010wave sensing variation detected on remote monitoring of ICD: What is the mechanism?","volume":"43","author":"De Mattia","year":"2020","journal-title":"Pacing Clin Electrophysiol"},{"key":"R24-20260820","doi-asserted-by":"crossref","first-page":"4083","DOI":"10.3390\/jcm10184083","article-title":"Mechanisms of exercise capacity improvement after cardiac rehabilitation following myocardial infarction assessed with combined stress echocardiography and cardiopulmonary exercise testing","volume":"10","author":"Smarz","year":"2021","journal-title":"J Clin Med"},{"key":"R25-20260820","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1186\/s12872-021-02325-7","article-title":"Regional contributions to left ventricular stroke volume determined by cardiac magnetic resonance imaging in cardiac resynchronization therapy","volume":"21","author":"\u00d6stenson","year":"2021","journal-title":"BMC Cardiovasc Disord"},{"key":"R26-20260820","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3390\/jcm8010035","article-title":"Safety of permanent pacemaker implantation: A prospective study","volume":"8","author":"Carri\u00f3n-Camacho","year":"2019","journal-title":"J Clin Med"},{"key":"R27-20260820","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jacc.2022.07.019","article-title":"Randomized trial of left bundle branch versus biventricular pacing for cardiac resynchronization therapy","volume":"80","author":"Wang","year":"2022","journal-title":"J Am Coll Cardiol"}],"container-title":["International Journal of Applied &amp; Basic Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijabmr.ijabmr_94_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T12:01:05Z","timestamp":1787227265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijabmr.ijabmr_94_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijabmr.ijabmr_94_26","relation":{},"ISSN":["2229-516X","2248-9606"],"issn-type":[{"value":"2229-516X","type":"print"},{"value":"2248-9606","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-03-18","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}