{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T13:10:11Z","timestamp":1789391411740,"version":"build-2803163510"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7]]},"DOI":"10.4103\/ijciis.ijciis_72_24","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T18:00:09Z","timestamp":1788544809000},"page":"117-119","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["What\u2019s new in critical illness and injury science? Sonographic assessment of optic nerve sheath diameter as a marker for raised intracranial pressure"],"prefix":"10.4103","volume":"14","author":[{"given":"Andrew C.","family":"Miller","sequence":"first","affiliation":[{"name":"Department of Emergency Medicine, Memorial Hospital Belleville, Belleville, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,9,20]]},"reference":[{"key":"R1-20260914","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1002\/jum.15732","article-title":"Optic nerve sheath diameter ultrasound for raised intracranial pressure:A literature review and meta-analysis of its diagnostic accuracy","volume":"41","author":"Aletreby","year":"2022","journal-title":"J Ultrasound Med"},{"key":"R2-20260914","doi-asserted-by":"crossref","first-page":"120853","DOI":"10.1016\/j.jns.2023.120853","article-title":"The role of optic nerve sheath ultrasonography in increased intracranial pressure:A systematic review and meta analysis","volume":"454","author":"Berhanu","year":"2023","journal-title":"J Neurol Sci"},{"key":"R3-20260914","doi-asserted-by":"crossref","first-page":"34","DOI":"10.3171\/jns.1997.87.1.0034","article-title":"Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure:Ultrasound findings during intrathecal infusion tests","volume":"87","author":"Hansen","year":"1997","journal-title":"J Neurosurg"},{"key":"R4-20260914","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1007\/s00134-014-3392-7","article-title":"Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury","volume":"40","author":"Sekhon","year":"2014","journal-title":"Intensive Care Med"},{"key":"R5-20260914","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.7863\/ultra.34.7.1285","article-title":"Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography:A systematic review and meta-analysis","volume":"34","author":"Ohle","year":"2015","journal-title":"J Ultrasound Med"},{"key":"R6-20260914","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1590\/0004-282x-anp-2020-0478","article-title":"The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma","volume":"79","author":"\u00c7elik","year":"2021","journal-title":"Arq Neuropsiquiatr"},{"key":"R7-20260914","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1590\/0004-282x-anp-2022-e006","article-title":"Measuring optic nerve sheath diameter using ultrasonography for the detection of non invasive intracranial pressure:What it is and what it is not","volume":"80","author":"Robba","year":"2022","journal-title":"Arq Neuropsiquiatr"},{"key":"R8-20260914","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1007\/s00381-020-04910-1","article-title":"Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients","volume":"37","author":"Biggs","year":"2021","journal-title":"Childs Nerv Syst"},{"key":"R9-20260914","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.annemergmed.2006.06.040","article-title":"Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients","volume":"49","author":"Tayal","year":"2007","journal-title":"Ann Emerg Med"}],"container-title":["International Journal of Critical Illness and Injury Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_72_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T13:00:51Z","timestamp":1789390851000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_72_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7]]},"references-count":9,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijciis.ijciis_72_24","relation":{},"ISSN":["2229-5151","2231-5004"],"issn-type":[{"value":"2229-5151","type":"print"},{"value":"2231-5004","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7]]},"assertion":[{"value":"2024-09-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}