{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T00:32:33Z","timestamp":1788654753665,"version":"build-2803163510"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Accurately monitoring blood glucose levels is vital for critically ill individuals. Point-of-care (POC) glucose meters are commonly used in local intensive care units (ICUs). This study aimed to assess the precision of POC glucose meter readings in critically ill individuals with specific evaluation in patients with and without shock against the reference standard of venous blood glucose measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>An observational study was done on adult patients admitted in the ICU at a teaching institution. Capillary blood samples were collected from the patient\u2019s fingertip using lancet device with aseptic measures. The sample was analyzed using the GlucoCare Sense Glucometer (RMD Mediaids Limited, Taiwan). At the same time, 2 ml of blood was drawn from the patient\u2019s peripheral veins and analyzed by glucose oxidase-peroxidase method as reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      POC glucose measurements averaged 140 \u00b1 20.23 mg\/dl, while laboratory values were recorded as 116.10 \u00b1 17.13 mg\/dl. The difference between the two methods was 24.34 \u00b1 12.01 mg\/dl. A strong correlation (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.805) was found between capillary and laboratory blood glucose levels, indicating a significant association (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). Twenty-two (44%) patients were in shock during the study. The mean difference between laboratory and POC blood glucose levels was higher in patients with circulatory shock (36.82 \u00b1 4.84 mg\/dl) than those without shock (14.61 \u00b1 4.49 mg\/dl),\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>POC glucose meters may lead to underdetection of hypoglycemia in critically ill patients, as their values are higher than laboratory values. Moreover, the results showed that POC glucometers are inaccurate for monitoring glucose in hypotensive patients in shock. Standard venous glucose monitoring methods may be more appropriate for these patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijciis.ijciis_76_23","type":"journal-article","created":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T07:05:52Z","timestamp":1718953552000},"page":"74-78","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Accuracy of point-of-care capillary blood sugar measurements in critically ill patients: An observational study"],"prefix":"10.4103","volume":"14","author":[{"given":"Keshabanand","family":"Mishra","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shivanand","family":"Mishra","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanmay","family":"Katial","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,6,21]]},"reference":[{"key":"R1-20240902","doi-asserted-by":"crossref","first-page":"191","DOI":"10.3949\/ccjm.89a.20171","article-title":"Glycemic control in the critically ill: Less is more","volume":"89","author":"Alhatemi","year":"2022","journal-title":"Cleve Clin J Med"},{"key":"R2-20240902","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1016\/j.chest.2019.05.016","article-title":"Percentage of time in range 70 to 139 mg\/dL is associated with reduced mortality among critically Ill patients receiving IV insulin infusion","volume":"156","author":"Lanspa","year":"2019","journal-title":"Chest"},{"key":"R3-20240902","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1097\/MCC.0000000000000621","article-title":"Is it time to abandon glucose control in critically ill adult patients?","volume":"25","author":"Krinsley","year":"2019","journal-title":"Curr Opin Crit Care"},{"key":"R4-20240902","doi-asserted-by":"crossref","first-page":"e541","DOI":"10.1097\/CCM.0000000000001353","article-title":"Prevalence and impact of unknown diabetes in the ICU","volume":"43","author":"Carpenter","year":"2015","journal-title":"Crit Care Med"},{"key":"R5-20240902","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1007\/s00134-021-06506-y","article-title":"Surviving sepsis campaign:International guidelines for management of sepsis and septic shock 2021","volume":"47","author":"Evans","year":"2021","journal-title":"Intensive Care Med"},{"key":"R6-20240902","doi-asserted-by":"crossref","first-page":"S244","DOI":"10.2337\/dc22-S016","article-title":"16. Diabetes care in the hospital: Standards of medical care in diabetes-2022","volume":"45","year":"2022","journal-title":"Diabetes Care"},{"key":"R7-20240902","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1186\/s13104-022-06256-0","article-title":"Comparing the accuracy of point-of-care with laboratory (capillary, venous, and arterial) blood glucose levels in critically ill patients with and without shock","volume":"15","author":"Alshaer","year":"2022","journal-title":"BMC Res Notes"},{"key":"R8-20240902","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1177\/193229681100500124","article-title":"Blood glucose testing in the hospital: Error sources and risk management","volume":"5","author":"Nichols","year":"2011","journal-title":"J Diabetes Sci Technol"},{"key":"R9-20240902","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.7326\/0003-4819-114-12-1020","article-title":"Fingerstick glucose determination in shock","volume":"114","author":"Atkin","year":"1991","journal-title":"Ann Intern Med"},{"key":"R10-20240902","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.ejim.2011.01.004","article-title":"Comparison between arterial and capillary blood glucose monitoring in patients with shock","volume":"22","author":"Juneja","year":"2011","journal-title":"Eur J Intern Med"},{"key":"R11-20240902","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.1007\/s00134-007-0835-4","article-title":"Accuracy of bedside capillary blood glucose measurements in critically ill patients","volume":"33","author":"Critchell","year":"2007","journal-title":"Intensive Care Med"},{"key":"R12-20240902","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1177\/1932296817727550","article-title":"ISO 15197:2013 evaluation of a blood glucose monitoring system's measurement accuracy","volume":"11","author":"Jendrike","year":"2017","journal-title":"J Diabetes Sci Technol"},{"key":"R13-20240902","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.diabres.2009.09.018","article-title":"Bedside capillary blood glucose measurements in critically ill patients:Influence of catecholamine therapy","volume":"87","author":"Fekih Hassen","year":"2010","journal-title":"Diabetes Res Clin Pract"},{"key":"R14-20240902","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1590\/S1516-31802009000500003","article-title":"Accuracy of different methods for blood glucose measurement in critically ill patients","volume":"127","author":"Pulzi J\u00fanior","year":"2009","journal-title":"Sao Paulo Med J"},{"key":"R15-20240902","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1177\/1932296814538608","article-title":"Accuracy of point-of-care blood glucose measurements in critically ill patients in shock","volume":"8","author":"Garingarao","year":"2014","journal-title":"J Diabetes Sci Technol"},{"key":"R16-20240902","doi-asserted-by":"crossref","first-page":"2778","DOI":"10.1097\/01.CCM.0000189939.10881.60","article-title":"Reliability of point-of-care testing for glucose measurement in critically ill adults","volume":"33","author":"Kanji","year":"2005","journal-title":"Crit Care Med"},{"key":"R17-20240902","first-page":"220S","article-title":"Accuracy of glucose measurements in critically ill patients in shock","volume":"128","author":"Chakravarthy","year":"2005","journal-title":"Chest"},{"key":"R18-20240902","doi-asserted-by":"crossref","first-page":"336","DOI":"10.4037\/ajcc2007.16.4.336","article-title":"Comparison of point-of-care and laboratory glucose analysis in critically ill patients","volume":"16","author":"Lacara","year":"2007","journal-title":"Am J Crit Care"},{"key":"R19-20240902","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1177\/1932296819858633","article-title":"Clinical reliability of point-of-care glucose testing in critically Ill patients","volume":"14","author":"Pilackas","year":"2020","journal-title":"J Diabetes Sci Technol"}],"container-title":["International Journal of Critical Illness and Injury Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_76_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:39:17Z","timestamp":1787067557000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_76_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijciis.ijciis_76_23","relation":{},"ISSN":["2229-5151","2231-5004"],"issn-type":[{"value":"2229-5151","type":"print"},{"value":"2231-5004","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"2023-12-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-02-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}