{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:20:39Z","timestamp":1787761239940,"version":"build-2784847793"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Endotracheal intubation (ETI) is a commonly performed emergency procedure used to secure the airways in critically ill patients. Despite its importance, ETI presents significant risks to patients with difficult airways. The availability of different types of laryngoscopes, most notably video laryngoscopes and direct laryngoscopes (DLs), has contributed to improved intubation success rates and reduced complications. While numerous studies have compared video laryngoscopes and DLs, there remains a limited synthesis of evidence evaluating the full range of all laryngoscopes across different patient population and clinical settings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A narrative synthesis approach was employed in this review. Relevant articles were obtained from multiple databases, including PubMed (MEDLINE), CINAHL, and PsycINFO. Articles published up to June 23, 2025, were considered for inclusion. The methodological rigor and reporting quality of each article were appraised. The screening and exclusion process were documented using the PRISMA flow diagram. Titles, abstracts, full texts, and reference lists of all retrieved articles were thoroughly reviewed to identify potentially relevant publications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Video laryngoscopes, particularly the McGrath, GlideScope, and C-MAC D-Blade, demonstrated superior performance compared to laryngoscopes. There was better first-pass success, better view of the larynx, less need for external adjusting maneuvers, and shorter time to intubation. Other devices such as Airtraq and Bonfils fiberscope have good results in some clinical settings, but are useful only where there is high operator dependence and have a more difficult learning curve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Video laryngoscopes have proven to be better than DLs in managing adult patients with difficult airways due to the advantages of the success rate, visualization of the glottis, and efficiency of the procedure. However, methodological heterogeneity and an absence of consistently high quality in clinical trial data lead to inadequate evidence for recommending one specific laryngoscope as being better for all difficult airway scenarios. Further well-designed high-quality clinical studies are required to determine the most effective laryngoscope for intubating adults with difficult airways across diverse clinical settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijciis.ijciis_97_25","type":"journal-article","created":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T05:00:14Z","timestamp":1771218014000},"page":"4-11","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparative effectiveness of laryngoscopes for successful intubation in difficult adult airways: A systematic review"],"prefix":"10.4103","volume":"16","author":[{"given":"Mohammad Jamil G.","family":"Alhemedi","sequence":"first","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bayan Saleh A.","family":"Zabin","sequence":"additional","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salim M. J. Bani","family":"Omar","sequence":"additional","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmoud H.","family":"Alrabab\u2019a","sequence":"additional","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazan","family":"Alkhsealat","sequence":"additional","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esraa A.","family":"Al-Nusour","sequence":"additional","affiliation":[{"name":"Prince Al-Hssein Bin Abdullah II Academy for Civil Protection, Department of Paramedic, Al-Balqa Applied University, Al-Salt, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,16]]},"reference":[{"key":"R1-20260420","doi-asserted-by":"crossref","first-page":"177","DOI":"10.21608\/mnj.2022.259016","article-title":"Endotracheal tube nursing care: Current evidence","volume":"9","author":"Saad","year":"2022","journal-title":"Mansoura Nurs J"},{"key":"R2-20260420","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13049-023-01115-8","article-title":"Pre-hospital endotracheal intubation in severe traumatic brain injury: Ventilation targets and mortality-a retrospective analysis of 308 patients","volume":"31","author":"Knapp","year":"2023","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"R3-20260420","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.amj.2015.12.013","article-title":"Airway management: A structured curriculum for critical care transport providers","volume":"35","author":"Kuszajewski","year":"2016","journal-title":"Air Med J"},{"key":"R4-20260420","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.ajem.2024.08.042","article-title":"Emergency medicine updates: Endotracheal intubation","volume":"85","author":"Long","year":"2024","journal-title":"Am J Emerg Med"},{"key":"R6-20260420","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/ALN.0000000000004002","article-title":"2022 American Society of Anesthesiologists practice guidelines for management of the difficult airway","volume":"136","author":"Apfelbaum","year":"2022","journal-title":"Anesthesiology"},{"key":"R7-20260420","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/1757-7241-22-10","article-title":"Use of the Airtraq\u00ae device for airway management in the prehospital setting \u2013 A retrospective study","volume":"22","author":"Gellerfors","year":"2014","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"R8-20260420","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1213\/ANE.0000000000001084","article-title":"First-attempt intubation success of video laryngoscopy in patients with anticipated difficult direct laryngoscopy: A multicenter randomized controlled trial comparing the C-MAC D-blade versus the GlideScope in a mixed provider and diverse patient population","volume":"122","author":"Aziz","year":"2016","journal-title":"Anesth Analg"},{"key":"R9-20260420","doi-asserted-by":"crossref","first-page":"363","DOI":"10.3390\/jpm12030363","article-title":"Comparisons of videolaryngoscopes for intubation undergoing general anesthesia: Systematic review and network meta-analysis of randomized controlled trials","volume":"12","author":"Lee","year":"2022","journal-title":"J Pers Med"},{"key":"R10-20260420","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1001\/jama.2022.23550","article-title":"Effect of remifentanil versus neuromuscular blockers during rapid sequence intubation on successful intubation without major complications among patients at risk of aspiration: A randomized clinical trial","volume":"329","author":"Grillot","year":"2023","journal-title":"JAMA"},{"key":"R11-20260420","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.amj.2019.06.004","article-title":"First-pass success intubations using video laryngoscopy versus direct laryngoscopy: A retrospective prehospital ambulance service study","volume":"38","author":"Eberlein","year":"2019","journal-title":"Air Med J"},{"key":"R12-20260420","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1186\/s12873-024-01136-1","article-title":"Outcome of video laryngoscopy versus direct laryngoscopy for emergency tracheal intubation in emergency department: A propensity score matching analysis","volume":"24","author":"Kongsawaddee","year":"2024","journal-title":"BMC Emerg Med"},{"key":"R13-20260420","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13054-023-04727-9","article-title":"Video versus direct laryngoscopy in critically ill patients: An updated systematic review and meta-analysis of randomized controlled trials","volume":"28","author":"Ara\u00fajo","year":"2024","journal-title":"Crit Care"},{"key":"R14-20260420","first-page":"CD009975","article-title":"Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates","volume":"5","author":"Lingappan","year":"2023","journal-title":"Cochrane Database Syst Rev"},{"key":"R15-20260420","doi-asserted-by":"crossref","first-page":"3186","DOI":"10.3390\/jcm13113186","article-title":"Videolaryngoscopy versus fiberoptic bronchoscopy for awake tracheal intubation: A systematic review and meta-analysis of randomized controlled trials","volume":"13","author":"Merola","year":"2024","journal-title":"J Clin Med"},{"key":"R16-20260420","doi-asserted-by":"crossref","first-page":"18626","DOI":"10.1038\/s41598-023-45173-5","article-title":"Network meta-analysis of comparative efficacy and safety of intubation devices in children","volume":"13","author":"Ming","year":"2023","journal-title":"Sci Rep"},{"key":"R17-20260420","doi-asserted-by":"crossref","first-page":"111274","DOI":"10.1016\/j.jclinane.2023.111274","article-title":"GlideScope versus C-MAC D-blade videolaryngoscope for double-lumen tube intubation in patients with anticipated difficult airways: A multi-center, prospective, randomized, controlled trial","volume":"91","author":"Huang","year":"2023","journal-title":"J Clin Anesth"},{"key":"R18-20260420","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1186\/s13063-023-07641-1","article-title":"Comparison of video laryngoscope, video stylet, and flexible videoscope for transoral endotracheal intubation in patients with difficult airways: A randomized, parallel-group study","volume":"24","author":"Zhang","year":"2023","journal-title":"Trials"},{"key":"R19-20260420","doi-asserted-by":"crossref","first-page":"6168","DOI":"10.3390\/jcm12196168","article-title":"Comparison of McGrath videolaryngoscope versus Macintosh laryngoscope in tracheal intubation: An updated systematic review","volume":"12","author":"Sansone","year":"2023","journal-title":"J Clin Med"},{"key":"R20-20260420","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3390\/medicina59020282","article-title":"Comparison of the McGRATH (TM) video laryngoscope and Macintosh laryngoscope for orotracheal intubation in a simulated difficult airway scenario: An open-label, randomized clinical trial","volume":"59","author":"Kim","year":"2023","journal-title":"Medicina (Kaunas)"},{"key":"R21-20260420","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1213\/ANE.0b013e3182a46fa9","article-title":"A comparison between the Bonfils intubation fiberscope and McCoy laryngoscope for tracheal intubation in patients with a simulated difficult airway","volume":"117","author":"Abdullah","year":"2013","journal-title":"Anesth Analg"},{"key":"R22-20260420","first-page":"289","article-title":"A randomised crossover trial comparing the Airtraq\u00ae NT, McGrath\u00ae MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin","volume":"66","author":"G\u00f3mez-R\u00edos","year":"2016","journal-title":"Rev Bras Anestesiol"},{"key":"R23-20260420","doi-asserted-by":"crossref","first-page":"28","DOI":"10.4038\/slja.v27i1.8370","article-title":"A comparative study of airtraq\u00ae and McCoy laryngoscopes for endotracheal intubation in adult patients with simulated difficult airway using a rigid cervical collar in elective surgeries under general anaesthesia","volume":"27","author":"Babu","year":"2019","journal-title":"Sri Lankan J Anaesthesiol"},{"key":"R24-20260420","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1007\/BF03021507","article-title":"Brief report: Tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway","volume":"55","author":"Byhahn","year":"2008","journal-title":"Can J Anaesth"}],"container-title":["International Journal of Critical Illness and Injury Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_97_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:28:11Z","timestamp":1787758091000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijciis.ijciis_97_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijciis.ijciis_97_25","relation":{},"ISSN":["2229-5151","2231-5004"],"issn-type":[{"value":"2229-5151","type":"print"},{"value":"2231-5004","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"2025-08-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}