{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:41:53Z","timestamp":1786653713410,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To compare and evaluate the occlusal variability\/discrepancy recorded using qualitative (articulating paper) and quantitative (T-scan) techniques in partially edentulous implant-supported restorations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A total of 20 patients in the age group of 25\u201361 yrs participated in this study. All the patients had more than one tooth replaced with implant-supported prosthesis. After three months of restoration, occlusion reevaluated was carried out using qualitative (articulating paper) and quantitative (T-scan). T-scan data were used to measure implant occlusion time, occlusion time, and the relative occlusal force (ROFs) on implant prosthesis. And the data were statistically evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The T-scan values showed high points on the implants in most of the patients, which could not be evaluated by that of articulating paper outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The occlusal harmony achieved from using qualitative analysis of articulating paper was not supported by the finding of the quantitative analysis (T-scan). Also the T-scan provided the time interval of occlusion of the implant-supported restorations, which would help in better defining the implant-protected occlusal.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>The T-scan occlusal analysis system provides ROF and time intervals of occlusal contact. This allows accurate occlusal equilibration of implant-supported restoration according to implant protected occlusal concept.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijdr.ijdr_191_23","type":"journal-article","created":{"date-parts":[[2024,2,16]],"date-time":"2024-02-16T10:01:22Z","timestamp":1708077682000},"page":"396-400","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Comparative Evaluation of Implant-Protected Occlusion in Partially Edentulous Fixed Restoration Using Qualitative and Quantitative Assessment \u2013 A Prospective Clinical Trial"],"prefix":"10.4103","volume":"34","author":[{"given":"Ramesh","family":"Chowdhary","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Branemark Osseointegration Center India, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Bukkapatnam","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Way 2 Smile Dental Care, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,2,16]]},"reference":[{"key":"R1-20250715","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1111\/j.1600-0501.2007.01439.x","article-title":"Comparison of survival and complication rates of tooth-supported fixed dental prostheses (fdps) and implant-supported fdps and single crowns (scs)","volume":"18","author":"Pjetursson","year":"2007","journal-title":"Clin Oral Implants Res"},{"key":"R2-20250715","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0022-3913(03)00212-9","article-title":"Clinical complications with implants and implant prostheses","volume":"90","author":"Goodacre","year":"2003","journal-title":"J Prosthet Dent"},{"key":"R3-20250715","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1111\/j.1600-0501.2004.01067.x","article-title":"Occlusal considerations in implant therapy: clinicalguidlines with biomechanical rationale","volume":"16","author":"Kim","year":"2005","journal-title":"Clin Oral Implants Res"},{"key":"R4-20250715","first-page":"65","article-title":"Implant occlusion: biomechanical considerations for implant -supported prosthesis","volume":"3","author":"Chen","year":"2008","journal-title":"J Dent Sci"},{"key":"R5-20250715","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1111\/j.1834-7819.2008.00043.x","article-title":"Occlusion in implant dentistry. A review of the literature of Prosthetic determinants and current concepts","volume":"53","author":"Gross","year":"2008","journal-title":"Aust Dent J"},{"key":"R6-20250715","first-page":"52","article-title":"Computerized occlusal analysis as an alternative occlusal indicator","volume":"34","author":"Afrashtehfar","year":"2016","journal-title":"J Cranio Sleep Pract"},{"key":"R7-20250715","doi-asserted-by":"crossref","first-page":"170","DOI":"10.4103\/0972-4052.41066","article-title":"Occlusion indicators: A review","volume":"7","author":"Babu","year":"2007","journal-title":"J Ind Prosthodont Soc"},{"key":"R8-20250715","doi-asserted-by":"crossref","first-page":"927","DOI":"10.5005\/jp-journals-10024-2151","article-title":"Post -insertion posterior single-implant occlusion changes at different intervals: A T-scan computerised occlusal analysis","volume":"18","author":"Madani","year":"2017","journal-title":"J Contemp Dent Pract"},{"key":"R9-20250715","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1034\/j.1600-0501.2000.011S1156.x","article-title":"Mechanical complications of dental implants","volume":"11","author":"Schwarz","year":"2000","journal-title":"Clin Oral Implants Res"},{"key":"R10-20250715","doi-asserted-by":"crossref","first-page":"7","DOI":"10.4047\/jap.2012.4.1.7","article-title":"Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis","volume":"4","author":"Qadeer","year":"2012","journal-title":"J Adv Prosthodont"},{"key":"R11-20250715","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2174\/1874210600701010001","article-title":"Determining a relationship between applied occlusal load and articulating paper mark area","volume":"1","author":"Carey","year":"2007","journal-title":"Open Dent J"},{"key":"R12-20250715","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/S0022-3913(85)80086-X","article-title":"Thickness and marking characteristics of occlusal registration strips","volume":"54","author":"Schelb","year":"1985","journal-title":"J Prosthet Dent"},{"key":"R13-20250715","first-page":"287","article-title":"Computerized occlusal analysis: a new technology","volume":"18","author":"Manes","year":"1987","journal-title":"Quintessence Int"},{"key":"R14-20250715","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1034\/j.1600-0501.1996.070208.x","article-title":"Loss of osseointegration caused by occlusal load of oral implants; a clinical and radiographic study in monkeys","volume":"7","author":"Isidor","year":"1996","journal-title":"Clin Oral Implant Res"},{"key":"R15-20250715","first-page":"425","article-title":"The influence of controlled occlusal overload on peri-implant tissue. Part 3: A histologic study in monkeys","volume":"15","author":"Miyata","year":"2000","journal-title":"Int J Oral Maxillofac Imp"},{"key":"R16-20250715","doi-asserted-by":"crossref","first-page":"302","DOI":"10.4317\/medoral.19477","article-title":"Influence of occlusal loading on peri-implant clinical parameters. A pilot study","volume":"19","author":"Pellicer-Chover","year":"2014","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"R17-20250715","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1046\/j.1365-2842.1999.00444.x","article-title":"A clinical evaluation of 76 implant supported suprastructures in the composite grafted maxilla","volume":"26","author":"Kaptein","year":"1999","journal-title":"J Oral Rehabilitate"},{"key":"R18-20250715","first-page":"360","article-title":"Load factor control for implants in the posterior partially edentulous segment","volume":"12","author":"Rangert","year":"1997","journal-title":"Int J Oral Maxillofac Implants"},{"key":"R19-20250715","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1111\/jopr.12552","article-title":"Occlusal pressure redistribution with single implant restorations","volume":"26","author":"Roque","year":"2017","journal-title":"J Prosthodont"},{"key":"R20-20250715","first-page":"751","article-title":"Non simultaneous tooth contact in combined implant and natural contact in combined implant and natural tooth occlusal schemes","volume":"13","author":"Kerstein","year":"2002","journal-title":"Pract Periodont Aesthet Dent"}],"container-title":["Indian Journal of Dental Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijdr.ijdr_191_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:41:24Z","timestamp":1786650084000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijdr.ijdr_191_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/ijdr.ijdr_191_23","relation":{},"ISSN":["0970-9290","1998-3603"],"issn-type":[{"value":"0970-9290","type":"print"},{"value":"1998-3603","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"2023-03-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-10-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}