{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T09:13:22Z","timestamp":1773479602261,"version":"3.50.1"},"reference-count":15,"publisher":"Scientific Scholar","content-domain":{"domain":["ijdvl.com"],"crossmark-restriction":true},"short-container-title":["IJDVL"],"abstract":"<jats:sec id=\"st1\">\n<jats:title>Introduction:<\/jats:title>\n<jats:p>Patients who receive orthopedic implants have been shown to develop sensitivity to its components and there are concerns that this sensitivity might lead to contact dermatitis or implant-related problems like loosening and\/or failure. The objective of the study was to determine the sensitizing potential of orthopedic implants.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st2\">\n<jats:title>Methods:<\/jats:title>\n<jats:p>Fifty-four patients undergoing knee, hip, or shoulder replacement surgeries between July 2014 and July 2015 were recruited. Patch tests were performed before the implant surgery with 10 allergens likely to be implicated in metal hypersensitivity. Postimplant patch test was performed 6 months after surgery. A majority of the patch tests were applied on the arms.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st3\">\n<jats:title>Results:<\/jats:title>\n<jats:p>Four positive reactions were recorded in the preimplant patch tests \u2013 three positive reactions to nickel and one to chromium. Thirty patients made themselves available for the follow-up patch test. The incidence of new contact sensitivity to components of implants was 13.8% (4\/29) at 6 months. One patient who had undergone knee replacement developed eczematous lesions around the knee joint after surgery. This patient tested negative to patch test at both the times.<\/jats:p>\n<\/jats:sec>\n<jats:sec id=\"st4\">\n<jats:title>Limitations:<\/jats:title>\n<jats:p>Short follow-up duration and performing patch tests on the arms, a site known to elicit less positive patch test response compared to the back in sensitized individuals, are limitations of the study. <jats:bold>Conclusion:<\/jats:bold> There is an increase in the sensitivity to implanted components after 6 months of joint replacement surgery. The incidence of new sensitivity to a component of the implant was 13.8% (4\/29). In this context, nickel is a good sensitizer and could sensitize 50% of patients who received a nickel-containing implant.<\/jats:p>\n<\/jats:sec>","DOI":"10.4103\/ijdvl.ijdvl_789_18","type":"journal-article","created":{"date-parts":[[2020,3,2]],"date-time":"2020-03-02T11:35:50Z","timestamp":1583148950000},"page":"826-830","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["An observational study to determine the sensitizing potential of orthopedic implants"],"prefix":"10.25259","volume":"87","author":[{"given":"Haridaran Anand","family":"Shanmugham","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanjeev","family":"Handa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dipankar","family":"De","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mandeep Singh","family":"Dhillon","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sameer","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"10894","published-online":{"date-parts":[[2021,2,10]]},"reference":[{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-1","doi-asserted-by":"publisher","first-page":"65","DOI":"10.2310\/6620.2011.10055","article-title":"Cutaneous and systemic hypersensitivity reactions to metallic implants","volume":"22","author":"Basko-Plluska","year":"2011","journal-title":"Dermatitis"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-2","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1111\/j.1610-0387.2008.06987.x","article-title":"Intolerance reactions to knee arthroplasty in patients with nickel\/cobalt allergy and disappearance of symptoms after revision surgery with titanium-based endoprostheses","volume":"7","author":"Dietrich","year":"2009","journal-title":"J Dtsch Dermatol Ges"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-3","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1016\/j.biomaterials.2007.11.038","article-title":"Sensitivity to implant materials in patients with total knee arthroplasties","volume":"29","author":"Granchi","year":"2008","journal-title":"Biomaterials"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-4","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1002\/jbm.b.30445","article-title":"Sensitivity to implant materials in patients undergoing total hip replacement","volume":"77","author":"Granchi","year":"2006","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-5","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1302\/0301-620X.73B1.1991768","article-title":"Sensitivity to titanium. A cause of implant failure?","volume":"73","author":"Lalor","year":"1991","journal-title":"J Bone Joint Surg Br"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-6","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1302\/0301-620X.74B6.1447242","article-title":"Lymphocyte response to polymethylmethacrylate in loose total hip prostheses","volume":"74","author":"Gil-Albarova","year":"1992","journal-title":"J Bone Joint Surg Br"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-7","doi-asserted-by":"publisher","first-page":"137287","DOI":"10.1155\/2015\/137287","article-title":"Biomaterial hypersensitivity: Is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty","volume":"2015","author":"Mitchelson","year":"2015","journal-title":"Biomed Res Int"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-8","first-page":"287","article-title":"Terminology of contact dermatitis","volume":"50","author":"Wilkinson","year":"1970","journal-title":"Acta Derm Venereol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-9","doi-asserted-by":"publisher","first-page":"194","DOI":"10.4103\/0378-6323.77465","article-title":"Patch test results from a contact dermatitis clinic in North India","volume":"77","author":"Handa","year":"2011","journal-title":"Indian J Dermatol Venereol Leprol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-10","doi-asserted-by":"publisher","first-page":"313","DOI":"10.4103\/0378-6323.34008","article-title":"Patch testing experience with 1000 patients","volume":"73","author":"Bajaj","year":"2007","journal-title":"Indian J Dermatol Venereol Leprol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-11","first-page":"257","article-title":"Patch test methods II Regional variations of patch test responses","volume":"45","author":"Magnusson","year":"1965","journal-title":"Acta Derm Venereol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-12","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.1302\/0301-620X.94B8.28135","article-title":"Metal hypersensitivity testing in patients undergoing joint replacement: A systematic review","volume":"94","author":"Granchi","year":"2012","journal-title":"J Bone Joint Surg Br"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-13","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1001\/archdermatol.2011.2561","article-title":"The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants","volume":"148","author":"Atanaskova Mesinkovska","year":"2012","journal-title":"Arch Dermatol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-14","first-page":"62","article-title":"Implantation of orthopaedic devices in patients with metal allergy","volume":"69","author":"Carlsson","year":"1989","journal-title":"Acta Derm Venereol"},{"key":"10.4103\/ijdvl.IJDVL_789_18\/ref-15","doi-asserted-by":"publisher","first-page":"646","DOI":"10.3109\/17453670903487008","article-title":"The association between metal allergy, total hip arthroplasty, and revision","volume":"80","author":"Thyssen","year":"2009","journal-title":"Acta Orthop"}],"container-title":["Indian Journal of Dermatology, Venereology and Leprology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ijdvl.com\/an-observational-study-to-determine-the-sensitizing-potential-of-orthopedic-implants-2\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ijdvl.com\/an-observational-study-to-determine-the-sensitizing-potential-of-orthopedic-implants-2\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,23]],"date-time":"2021-10-23T09:43:06Z","timestamp":1634982186000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ijdvl.com\/an-observational-study-to-determine-the-sensitizing-potential-of-orthopedic-implants-2\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,10]]},"references-count":15,"alternative-id":["10.4103\/ijdvl.IJDVL_789_18"],"URL":"https:\/\/doi.org\/10.4103\/ijdvl.ijdvl_789_18","relation":{},"ISSN":["0378-6323"],"issn-type":[{"value":"0378-6323","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,10]]},"article-number":"826"}}