{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:24:59Z","timestamp":1787757899996,"version":"build-2784847793"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","license":[{"start":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T00:00:00Z","timestamp":1770768000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Comparative evaluation of the corneal biomechanical parameters by the dynamic corneal response imaging with CORVIS-ST ST in normal and post-keratoplasty eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Cross-sectional observational study of CORVIS-ST imaging of 150 normal corneas and 150 post-keratoplasty corneas was done to evaluate corneal biomechanics of normal Asian-Indian corneas and post-keratoplasty corneas. Data on demographic details, postoperative period, visual acuity (UCVA, BCVA) (logmar units), refraction, axial length (D), corneal topography Scheimpflug\u2019s imaging with Pentacam [Anterior-K1(AK1), Anterior-K2 (AK2), Posterior-K1(PK1), PosteriorK2(PK2), Mean keratometry (Kmean), Keratometry maximum (Kmax), Q-value, D-value, Thinnest pachymetry (TP), Corneal elevation [anterior (CE ant) and posterior (CE post)], CORVIS-ST imaging (bIOP, 1\n                      <jats:sup>st<\/jats:sup>\n                      and 2\n                      <jats:sup>nd<\/jats:sup>\n                      Appl time HCT, 1\n                      <jats:sup>st<\/jats:sup>\n                      Appl length, DA, TBI, CBI, HC rad, Vel in and out, DA ratio, IR, Inv CR, SSI, SPA1, ARTh) were recorded.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Comparative evaluation of CORVIS-ST in 150 normal corneas [mean age 32.54 \u00b1 10 (9\u201368) years] and 150 post-keratoplasty corneas [mean age 35.14 \u00b1 16.96 (8\u201372) years; PK (58), DSAEK (29), DALK (58), HALK (8), and SALK (3)] noted 18 parameters (bIOP, 1\n                      <jats:sup>st<\/jats:sup>\n                      and 2\n                      <jats:sup>nd<\/jats:sup>\n                      Appl time HCT, 1\n                      <jats:sup>st<\/jats:sup>\n                      Appl length, DA, TBI, CBI, HC rad, Vel in and out, DA ratio, IR, Inv CR, SSI, SPA1, ARTh) and showed that 12 of these were statistically different in post-keratoplasty corneas. Parameters of DA, TBI, CBI, IR, and Inv CR were higher, whereas HC rad, SSI, SPA1, and ARTh showed significantly lesser values in post-keratoplasty corneas as compared to normal corneas. Subgroup analysis (PK, DSAEK, DALK, HALK) showed eyes that underwent DSAEK had biomechanical values closest to that of normal corneas. Post-DALK in comparison to post-PK corneas showed significantly higher values in CBI and IR, and lower values in HC rad, SSI, and ARTh (0.87 \u00b1 0.17, 9.9 \u00b1 3.5, 0.85 \u00b1 0.25, 190.92 \u00b1 119.06 and 0.71 \u00b1 0.25, 8.19 \u00b1 1.92, 1.02 \u00b1 0.38, and 340.90 \u00b1 178.37, respectively). Correlational analysis showed significant mild positive correlation of CBI with corneal curvature in normal and post-PK corneas (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004 and 0.040, respectively).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Post-keratoplasty corneas were seen to have lesser biomechanical strength as compared to normal corneas. Post-DSAEK corneas had a better biomechanical strength than other groups and closest biomechanics to normal corneas. Post-DALK in comparison to post-PK corneas showed a lower biomechanical strength in our study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1029_25","type":"journal-article","created":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T10:00:10Z","timestamp":1770804010000},"page":"S103-S113","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Corneal biomechanics with CORVIS-ST in post-keratoplasty corneas"],"prefix":"10.4103","volume":"74","author":[{"given":"Tapashree","family":"Ghosh","sequence":"first","affiliation":[{"name":"Cornea and Ocular Surface, Cataract and Refractive Services, Dr. R P Centre for Ophthalmic Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Murugesan","family":"Vanathi","sequence":"additional","affiliation":[{"name":"Cornea and Ocular Surface, Cataract and Refractive Services, Dr. R P Centre for Ophthalmic Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noopur","family":"Gupta","sequence":"additional","affiliation":[{"name":"Cornea and Ocular Surface, Cataract and Refractive Services, Dr. R P Centre for Ophthalmic Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Radhika","family":"Tandon","sequence":"additional","affiliation":[{"name":"Cornea and Ocular Surface, Cataract and Refractive Services, Dr. R P Centre for Ophthalmic Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maroof","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,11]]},"reference":[{"key":"R1-20260430","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.survophthal.2018.05.004","article-title":"Biomechanics and structure of the cornea: implications and association with corneal disorders","volume":"63","author":"Ma","year":"2018","journal-title":"Surv Ophthalmol"},{"key":"R2-20260430","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/cxo.12230","article-title":"Corneal biomechanics: A review","volume":"98","author":"Pi\u00f1ero","year":"2015","journal-title":"Clin Exp Optom"},{"key":"R3-20260430","doi-asserted-by":"crossref","first-page":"108508","DOI":"10.1016\/j.exer.2021.108508","article-title":"Corneal biomechanics: Measurement and structural correlations","volume":"205","author":"Chong","year":"2021","journal-title":"Exp Eye Res"},{"key":"R4-20260430","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s40662-020-0174-x","article-title":"Biomechanical diagnostics of the cornea","volume":"7","author":"Esporcatte","year":"2020","journal-title":"Eye Vis (Lond)"},{"key":"R5-20260430","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jfo.2017.06.006","article-title":"Intraocular pressure measurements and corneal biomechanical properties using a dynamic Scheimpflug analyzer, after several keratoplasty techniques, versus normal eyes","volume":"41","author":"Hugo","year":"2018","journal-title":"J Fr Ophtalmol"},{"key":"R6-20260430","doi-asserted-by":"crossref","first-page":"100074","DOI":"10.1016\/j.medntd.2021.100074","article-title":"Review of ex-vivo characterisation of corneal biomechanics","volume":"11","author":"Wang","year":"2021","journal-title":"Med Nov Technol Devices"},{"key":"R7-20260430","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1111\/ceo.13677","article-title":"Comparison of corneal biomechanical properties following penetrating keratoplasty and deep anterior lamellar keratoplasty for keratoconus","volume":"48","author":"Ziaei","year":"2020","journal-title":"Clin Exp Ophthalmol"},{"key":"R8-20260430","doi-asserted-by":"crossref","first-page":"454","DOI":"10.4103\/0301-4738.119317","article-title":"Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer","volume":"62","author":"Murugesan","year":"2014","journal-title":"Indian J Ophthalmol"},{"key":"R9-20260430","doi-asserted-by":"crossref","first-page":"2964","DOI":"10.4103\/ijo.IJO_1453_20","article-title":"Study on change in corneal biomechanics and effect of percent tissue altered in myopic laser-assisted in situ keratomileusis","volume":"68","author":"Vanathi","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R10-20260430","doi-asserted-by":"crossref","first-page":"e567","DOI":"10.1111\/aos.12136","article-title":"Influence of different keratoplasty techniques on the biomechanical properties of the cornea","volume":"91","author":"Abdelkader","year":"2013","journal-title":"Acta Ophthalmol"},{"key":"R11-20260430","doi-asserted-by":"crossref","first-page":"5676","DOI":"10.1038\/s41598-020-62825-y","article-title":"Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes","volume":"10","author":"Yang","year":"2020","journal-title":"Sci Rep"},{"key":"R12-20260430","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jfo.2017.06.006","article-title":"Intraocular pressure measurements and corneal biomechanical properties using a dynamic Scheimpflug analyzer, after several keratoplasty techniques, versus normal eyes","volume":"41","author":"Hugo","year":"2017","journal-title":"J Fr Ophtalmol"},{"key":"R13-20260430","doi-asserted-by":"crossref","first-page":"24","DOI":"10.18502\/jovr.v15i1.5936","article-title":"Corneal parameters in healthy subjects assessed by Corvis ST","volume":"15","author":"Salouti","year":"2020","journal-title":"J Ophthalmic Vis Res"},{"key":"R14-20260430","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1097\/ICO.0000000000002318","article-title":"Post-LASIK ectasia versus keratoconus: An in vivo confocal microscopy study: An in vivo confocal microscopy study","volume":"39","author":"Alvani","year":"2020","journal-title":"Cornea"},{"key":"R15-20260430","doi-asserted-by":"crossref","first-page":"3041","DOI":"10.1038\/s41598-020-80915-9","article-title":"Assessment of corneal biomechanics, tonometry and pachymetry with the Corvis ST in myopia","volume":"11","author":"Wang","year":"2021","journal-title":"Sci Rep"},{"key":"R16-20260430","doi-asserted-by":"crossref","first-page":"8618615","DOI":"10.1155\/2020\/8618615","article-title":"Comparison of corneal biomechanical properties among axial myopic, nonaxial myopic, and nonmyopic eyes","volume":"2020","author":"Tubtimthong","year":"2020","journal-title":"Biomed Res Int"},{"key":"R17-20260430","doi-asserted-by":"crossref","first-page":"13","DOI":"10.2174\/1874364102115010013","article-title":"Ethnic differences of corneal parameters: A cross-sectional study","volume":"15","author":"Alsaqr","year":"2021","journal-title":"Open Ophthalmol J"},{"key":"R18-20260430","doi-asserted-by":"crossref","first-page":"834663","DOI":"10.3389\/fmed.2022.834663","article-title":"Corneal biomechanics differences between Chinese and Caucasian healthy subjects","volume":"9","author":"Vinciguerra","year":"2022","journal-title":"Front Med"},{"key":"R19-20260430","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1007\/s10384-014-0344-2","article-title":"Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer","volume":"58","author":"Maeda","year":"2014","journal-title":"Jpn J Ophthalmol"},{"key":"R20-20260430","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.18240\/ijo.2022.07.13","article-title":"Short and long term corneal biomechanical analysis after overnight orthokeratology","volume":"15","author":"Nieto-Bona","year":"2022","journal-title":"Int J Ophthalmol"},{"key":"R21-20260430","first-page":"1","article-title":"Correlations among corneal biomechanical parameters, stiffness, and thickness measured using corvis ST and pentacam in patients with ocular hypertension","volume":"2022","author":"Liu","year":"2022","journal-title":"J Ophthalmol"},{"key":"R22-20260430","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1080\/02713683.2019.1658787","article-title":"Early diagnosis of keratoconus in Chinese myopic eyes by combining corvis ST with pentacam","volume":"45","author":"Zhang","year":"2019","journal-title":"Curr Eye Res"},{"key":"R23-20260430","doi-asserted-by":"crossref","first-page":"2921","DOI":"10.4103\/ijo.IJO_2127_19","article-title":"Age-related variation in corneal biomechanical parameters in healthy Indians","volume":"68","author":"Kenia","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R24-20260430","first-page":"2173","article-title":"Age-related analysis of corneal biomechanical parameters in healthy Chinese individuals","volume":"14","author":"Guo","year":"2024","journal-title":"Sci Rep"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1029_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T14:55:26Z","timestamp":1787756126000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1029_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,11]]},"references-count":24,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1029_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,11]]},"assertion":[{"value":"2025-04-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}