{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:59:29Z","timestamp":1787169569481,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To analyze the refractive shift during off-the-axis retinoscopy under cycloplegic drugs in myopic patients during ocular examination.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Prospective cross-sectional study was carried out among 10 myopic patients having refractive errors of \u22123.00 D or less. All the subjects underwent cycloplegic refraction by a single examiner at 0\u00b0, 10\u00b0, and 20\u00b0. Descriptive data were analyzed as mean and standard deviation. Paired t-test was used to compare the mean differences between on-axis (0\u00b0) and off-axis (10\u00b0 and 20\u00b0) retinoscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Result:<\/jats:title>\n                    <jats:p>\n                      The mean spherical equivalent refraction of 10 myopic patients showed an increase in myopic shift with approximately 7% and 18% for 10\u00b0 and 20\u00b0 of eccentricity, respectively. Similarly, the mean spherical equivalent measure on axis (0\u00b0) and off axis (10\u00b0 and 20\u00b0) were -2.5495, \u22122.737, and \u22123.0265, respectively. The mean spherical equivalent differences between on-axis (0\u00b0) and off-axis (10\u00b0 and 20\u00b0) showed statistically significant differences with\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This study concluded that a greater degree of eccentricity will induce a greater amount of errors in retinoscopy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1123_21","type":"journal-article","created":{"date-parts":[[2022,2,25]],"date-time":"2022-02-25T08:01:36Z","timestamp":1645776096000},"page":"779-781","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Refractive changes during off-the-axis retinoscopy in myopia"],"prefix":"10.4103","volume":"70","author":[{"given":"Ritesh Kumar","family":"Chaurasiya","sequence":"first","affiliation":[{"name":"Department of Optometry, Sanjivni Eye and Medicare Centre, Ambala, Haryana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,2,25]]},"reference":[{"key":"B4-20240828","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1364\/JOSA.64.000510","article-title":"Peripheral astigmatism in the human eye:Experimental data and theoretical model predictions","volume":"64","author":"Lotmar","year":"1974","journal-title":"J Opt Soc Am"},{"key":"B5-20240828","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1111\/cxo.12943","article-title":"Peripheral refraction and higher order aberrations","volume":"103","author":"Romashchenko","year":"2020","journal-title":"Clin Exp Optometry"},{"key":"B6-20240828","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1001\/archopht.1933.00830010949006","article-title":"Interpretation of refractive conditions in the peripheral field of vision:A further study","volume":"9","author":"Ferree","year":"1933","journal-title":"Arch Ophthalmol"},{"key":"B7-20240828","first-page":"1","article-title":"On emmetropia and ametropia","volume":"142","author":"Van","year":"1961","journal-title":"Opt Acta (Lond)"},{"key":"B8-20240828","doi-asserted-by":"crossref","first-page":"1892","DOI":"10.1364\/BOE.387254","article-title":"Peripheral image quality in pseudophakic eyes","volume":"11","author":"Togka","year":"2020","journal-title":"Biomed Opt Express"},{"key":"B9-20240828","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1097\/00006324-200410000-00007","article-title":"Refractive astigmatism and the toricity of ocular components in human infants","volume":"81","author":"Mutti","year":"2004","journal-title":"Optometry Vis Sci"},{"key":"B10-20240828","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/j.ajo.2004.02.012","article-title":"The effect of off-the-visual-axis retinoscopy on objective refractive measurement","volume":"137","author":"Jackson","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"B11-20240828","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1038\/eye.2011.79","article-title":"The impact of off the visual axis retinoscopy on objective central refractive measurement in adult clinical practice:A prospective, randomized clinical study","volume":"25","author":"Tay","year":"2011","journal-title":"Eye"},{"key":"B12-20240828","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1001\/archopht.118.1.17","article-title":"Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism","volume":"118","author":"Seiler","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"B13-20240828","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/S0886-3350(13)80699-2","article-title":"Effects of intraocular lens position errors on postoperative refractive error","volume":"16","author":"Erickson","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"B14-20240828","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1001\/archopht.1990.01070090047037","article-title":"Classification of normal corneal topography based on computer-assisted videokeratography","volume":"108","author":"Bogan","year":"1990","journal-title":"Arch Ophthalmol"},{"key":"B15-20240828","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1111\/j.1740-8261.1999.tb00382.x","article-title":"Agreement between A-mode and B-mode ultrasonography in the measurement of ocular distances","volume":"40","author":"Hamidzada","year":"1999","journal-title":"Vet Radiology Ultrasound"},{"key":"B16-20240828","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.visres.2009.10.004","article-title":"Characteristics of peripheral refractive errors of myopic and non-myopic Chinese eyes","volume":"50","author":"Chen","year":"2010","journal-title":"Vis Res"},{"key":"B17-20240828","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1097\/OPX.0b013e3181d951f7","article-title":"Peripheral refraction in myopic patients after orthokeratology","volume":"87","author":"Queir\u00f3s","year":"2010","journal-title":"Optom Vis Sci"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_1123_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:07:35Z","timestamp":1787166455000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_1123_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,25]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1123_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,25]]},"assertion":[{"value":"2021-05-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-10-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}