{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T10:55:49Z","timestamp":1793876149679,"version":"4.7.0"},"reference-count":89,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:00Z","timestamp":1740528000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:p>This narrative review aims to compare and document various studies on pediatric intraocular lens (IOL) power calculation, highlighting the differences from adult IOL power calculations and assessing the need for accurate ophthalmic biometry and targeted refraction to improve visual outcomes and reduce amblyopia risk. A comprehensive search of the PubMed database was conducted using keywords such as \u201cpediatric cataract surgery,\u201d \u201cIOL power calculation,\u201d \u201cocular biometry,\u201d and \u201cIOL formulas.\u201d Relevant articles were identified by evaluating titles and abstracts, followed by full-text examination. References were reviewed for thorough coverage. Pediatric eyes pose unique challenges for IOL power calculation due to smaller size, changing axial length, and corneal curvature. Accurate biometry, particularly axial length and keratometry, is crucial. Studies comparing IOL formulas, primarily developed for adults, show varying prediction errors in pediatric cases. Newer-generation formulas such as Barrett\u2019s Universal II and Kane demonstrate superior accuracy compared to older formulas (e.g., SRK\/T). Undercorrection strategies account for myopic shifts due to eye growth, but consensus on the best formula and target refraction is lacking. Premium IOLs, such as multifocal and toric, offer benefits but require further long-term evaluation. Accurate IOL power calculation is critical for optimal visual outcomes in pediatric cataract surgery. While newer IOL formulas show promise, the unpredictable nature of eye growth and myopic shifts complicates long-term predictions. Premium IOLs offer potential advantages but necessitate careful consideration. Continuous advancements in IOL technology and personalized approaches to target refraction are essential to improve the quality of life of pediatric patients.<\/jats:p>","DOI":"10.4103\/ijo.ijo_1205_24","type":"journal-article","created":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T03:06:30Z","timestamp":1740539190000},"page":"312-319","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Pediatric IOL power calculation: Factors and considerations"],"prefix":"10.4103","volume":"73","author":[{"given":"Aishwarya","family":"Rathod","sequence":"first","affiliation":[{"name":"Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudarshan","family":"Khokhar","sequence":"additional","affiliation":[{"name":"Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deeksha","family":"Rani","sequence":"additional","affiliation":[{"name":"Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"R1-20260422","first-page":"227","article-title":"Childhood blindness in the context of VISION 2020--the right to sight","volume":"79","author":"Gilbert","year":"2001","journal-title":"Bull World Health Organ"},{"key":"R2-20260422","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.4103\/ijo.IJO_1023_17","article-title":"Pediatric cataract","volume":"65","author":"Khokhar","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R3-20260422","first-page":"77","article-title":"Pediatric cataract: Challenges and future directions","volume":"9","author":"Medsinge","year":"2015","journal-title":"Clin Ophthalmol Auckl NZ"},{"key":"R4-20260422","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1097\/00055735-200002000-00008","article-title":"Intraocular lens implantation in children","volume":"11","author":"Dahan","year":"2000","journal-title":"Curr Opin Ophthalmol"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1001\/jamaophthalmol.2015.2062","article-title":"Long-term results of pediatric cataract surgery and primary intraocular lens implantation from 7 to 22 months of life","volume":"133","author":"Struck","year":"2015","journal-title":"JAMA Ophthalmol"},{"key":"R6-20260422","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1016\/S0886-3350(03)00220-7","article-title":"Pediatric cataract surgery and intraocular lens implantation: Practice styles and preferences of the 2001 ASCRS and AAPOS memberships","volume":"29","author":"Wilson","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R7-20260422","first-page":"72","article-title":"Visual results after primary intraocular lens implantation or contact lens correction for aphakia in the first year of age","volume":"219","author":"Autrata","year":"2005","journal-title":"Ophthalmol J Int Ophtalmol Int J Ophthalmol Z Augenheilkd"},{"key":"R8-20260422","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1016\/j.ajo.2014.07.031","article-title":"Complications in the first 5 years following cataract surgery in infants with and without intraocular lens implantation in the Infant Aphakia Treatment Study","volume":"158","author":"Plager","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1001\/jamaophthalmol.2014.531","article-title":"Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: A randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years","volume":"132","author":"Lambert","year":"2014","journal-title":"JAMA Ophthalmol"},{"key":"R10-20260422","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1038\/eye.2016.171","article-title":"Comparison of IOL power calculation formulae for pediatric eyes","volume":"30","author":"Vasavada","year":"2016","journal-title":"Eye"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.jcrs.2003.07.002","article-title":"Early postoperative refractive outcomes of pediatric intraocular lens implantation","volume":"30","author":"Mezer","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1016\/j.ophtha.2009.12.031","article-title":"Comparison of intraocular lens power calculation formulae in pediatric eyes","volume":"117","author":"Nihalani","year":"2010","journal-title":"Ophthalmology"},{"key":"R14-20260422","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.survophthal.2007.06.010","article-title":"Intraocular lens power calculation in children","volume":"52","author":"Eibschitz-Tsimhoni","year":"2007","journal-title":"Surv Ophthalmol"},{"key":"R15-20260422","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3928\/0191-3913-19970701-12","article-title":"Predictive value of regression and theoretical IOL formulas in pediatric intraocular lens implantation","volume":"34","author":"Andreo","year":"1997","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R16-20260422","doi-asserted-by":"crossref","first-page":"2877","DOI":"10.1007\/s00417-022-05779-3","article-title":"Evaluation of IOL power calculation with the Kane formula for pediatric cataract surgery","volume":"260","author":"Reitblat","year":"2022","journal-title":"Graefes Arch Clin Exp Ophthalmol Albrecht Von Graefes Arch Klin Exp Ophthalmol"},{"key":"R17-20260422","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3928\/01913913-20220811-01","article-title":"Predictive accuracy of the Hill-RBF 2.0 formula in pediatric eyes: Comparison of 5 intraocular lens formulas","volume":"60","author":"Rastogi","year":"2023","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R18-20260422","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0886-3350(13)80917-0","article-title":"Sources of error in intraocular lens power calculation","volume":"18","author":"Olsen","year":"1992","journal-title":"J Cataract Refract Surg"},{"key":"R19-20260422","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.sjopt.2011.11.002","article-title":"Axial length measurement techniques in pediatric eyes with cataract","volume":"26","author":"Wilson","year":"2012","journal-title":"Saudi J Ophthalmol"},{"key":"R20-20260422","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.ophtha.2010.06.042","article-title":"Axial length measurements by contact and immersion techniques in pediatric eyes with cataract","volume":"118","author":"Trivedi","year":"2011","journal-title":"Ophthalmology"},{"key":"R21-20260422","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.jcrs.2010.09.023","article-title":"Prediction error after pediatric cataract surgery with intraocular lens implantation: Contact versus immersion A-scan biometry","volume":"37","author":"Trivedi","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R22-20260422","first-page":"440","article-title":"Accuracy of IOL calculations in children: A comparison of immersion versus contact A-scan biometery","volume":"12","author":"Ben-Zion","year":"2008","journal-title":"J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R23-20260422","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.4103\/ijo.IJO_1327_18","article-title":"Biometric changes in Indian pediatric cataract and postoperative refractive status","volume":"67","author":"Khokhar","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"R24-20260422","doi-asserted-by":"crossref","first-page":"221","DOI":"10.4103\/jcsr.jcsr_23_21","article-title":"Keratometry in paediatric eyes with cataract in Indian population","volume":"10","author":"Vasavada","year":"2021","journal-title":"J Clin Sci Res"},{"key":"R25-20260422","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.4103\/ijo.IJO_269_21","article-title":"Comparing keratometry readings with manual separation of lids and wire speculum in children under general anesthesia","volume":"69","author":"Jethani","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R26-20260422","doi-asserted-by":"crossref","first-page":"663","DOI":"10.18231\/j.ijceo.2021.133","article-title":"Keratometry using hand-held and automated keratometers with and without speculum in Indian pediatric cataract \u2013 A comparative study","volume":"7","author":"Jat","year":"2022","journal-title":"Indian J Clin Exp Ophthalmol"},{"key":"R27-20260422","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1016\/j.jcrs.2008.07.019","article-title":"Accuracy of biometry in pediatric cataract extraction with primary intraocular lens implantation","volume":"34","author":"Moore","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R28-20260422","doi-asserted-by":"crossref","first-page":"85","DOI":"10.4103\/jcor.jcor_54_17","article-title":"Repeatability of manual and portable handheld automated keratometric measurements in pediatric population","volume":"6","author":"Raj","year":"2018","journal-title":"J Clin Ophthalmol Res"},{"key":"R29-20260422","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/S0886-3350(98)80333-7","article-title":"Validation of a handheld automated keratometer in adults","volume":"24","author":"Noonan","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R30-20260422","first-page":"60","article-title":"Clinical comparison of automated and manual keratometry in pre-operative ocular biometry","volume":"6","author":"Sunderraj","year":"1992","journal-title":"Eye Lond Engl"},{"key":"R31-20260422","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.optom.2018.12.002","article-title":"Keratometry in children: Comparison between auto-refractokeratometer, rotating scheimpflug imaging, and biograph","volume":"12","author":"Hashemi","year":"2019","journal-title":"J Optom"},{"key":"R32-20260422","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1007\/s10792-013-9895-3","article-title":"Keratometry with five different techniques: A study of device repeatability and inter-device agreement","volume":"34","author":"Mehravaran","year":"2014","journal-title":"Int Ophthalmol"},{"key":"R33-20260422","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1001\/archophthalmol.2007.22","article-title":"Keratometry in pediatric eyes with cataract","volume":"126","author":"Trivedi","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"R34-20260422","first-page":"99","article-title":"Keratometry in children","volume":"16","author":"Asbell","year":"1990","journal-title":"CLAO J Off Publ Contact Lens Assoc Ophthalmol Inc"},{"key":"R35-20260422","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.jcrs.2004.04.063","article-title":"Change in IOL position and capsular bag size with an angulated intraocular lens early after cataract surgery","volume":"31","author":"Koeppl","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R36-20260422","doi-asserted-by":"crossref","first-page":"152","DOI":"10.5935\/0004-2749.20140039","article-title":"Ocular biometry and central corneal thickness in children: A hospital-based study","volume":"77","author":"Gul","year":"2014","journal-title":"Arq Bras Oftalmol"},{"key":"R37-20260422","doi-asserted-by":"crossref","first-page":"e403","DOI":"10.1111\/aos.13599","article-title":"Agreement of phakic and pseudophakic anterior chamber depth measurements in IOLMaster and Pentacam","volume":"96","author":"Hamoudi","year":"2018","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"R38-20260422","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/ICL.0000000000000718","article-title":"The myopic shift in aphakic eyes in the infant Aphakia treatment study after 10 years of follow-up","volume":"47","author":"Lambert","year":"2021","journal-title":"Eye Contact Lens"},{"key":"R39-20260422","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.jcrs.2009.11.017","article-title":"Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter","volume":"36","author":"Kawamorita","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R40-20260422","doi-asserted-by":"crossref","first-page":"4543","DOI":"10.2147\/OPTH.S344465","article-title":"Cataract surgery in short eyes, including nanophthalmos: Visual outcomes, complications and refractive results","volume":"15","author":"Yosar","year":"2021","journal-title":"Clin Ophthalmol Auckl NZ"},{"key":"R41-20260422","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/s10792-018-0859-5","article-title":"A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: Correlation between ocular biometric parameters","volume":"39","author":"Ghoreishi","year":"2019","journal-title":"Int Ophthalmol"},{"key":"R42-20260422","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/S0886-3350(88)80087-7","article-title":"Comparison of the SRK II formula and other second generation formulas","volume":"14","author":"Sanders","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R43-20260422","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R44-20260422","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: A comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R45-20260422","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: A review","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol Scand"},{"key":"R46-20260422","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1136\/bjo.85.8.939","article-title":"Accuracy of intraocular lens power calculation in paediatric cataract surgery","volume":"85","author":"Tromans","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"R47-20260422","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/j.jcrs.2011.01.021","article-title":"Accuracy of the Holladay 2 intraocular lens formula for pediatric eyes in the absence of preoperative refraction","volume":"37","author":"Trivedi","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R48-20260422","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1016\/S0886-3350(97)80317-3","article-title":"Intraocular lens power calculation for microphthalmos","volume":"23","author":"Inatomi","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R49-20260422","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1016\/j.ajo.2013.07.014","article-title":"Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: Results from the infant Aphakia treatment study","volume":"156","author":"Vanderveen","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"R50-20260422","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1007\/s00417-022-05896-z","article-title":"Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients","volume":"261","author":"Lin","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol Albrecht Von Graefes Arch Klin Exp Ophthalmol"},{"key":"R51-20260422","first-page":"e24991","article-title":"Comparative evaluation of intraocular lens power calculation formulas in children","volume":"14","author":"Rastogi","year":"2022","journal-title":"Cureus"},{"key":"R52-20260422","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1007\/s00417-024-06401-4","article-title":"Refractive predictive errors using Barrett II, Hoffer-Q, and SRKT formulae for pediatric IOL implantation","volume":"262","author":"Shmueli","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol Albrecht Von Graefes Arch Klin Exp Ophthalmol"},{"key":"R53-20260422","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ajo.2011.11.031","article-title":"Accuracy of intraocular lens power calculation formulae in children less than two years","volume":"154","author":"Kekunnaya","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R54-20260422","first-page":"330","article-title":"IOL power calculation in short and long eyes","volume":"6","author":"Hoffer","year":"2017","journal-title":"Asia Pac J Ophthalmol Phila Pa"},{"key":"R55-20260422","first-page":"173","article-title":"Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients","volume":"12","author":"Eibschitz-Tsimhoni","year":"2008","journal-title":"J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R56-20260422","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/ICU.0000000000000536","article-title":"Biometry in cataract surgery: A review of the current literature","volume":"30","author":"Moshirfar","year":"2019","journal-title":"Curr Opin Ophthalmol"},{"key":"R57-20260422","doi-asserted-by":"crossref","first-page":"1754","DOI":"10.1016\/j.jcrs.2008.06.021","article-title":"Accuracy of preoperative biometry in vitrectomy combined with cataract surgery for patients with epiretinal membranes and macular holes: Results of a prospective controlled clinical trial","volume":"34","author":"Falkner-Radler","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R58-20260422","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/S0886-3350(98)80108-9","article-title":"Intraocular lens calculator for childhood cataract","volume":"24","author":"McClatchey","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R59-20260422","doi-asserted-by":"crossref","first-page":"813","DOI":"10.4103\/ijo.IJO_163_17","article-title":"Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation","volume":"65","author":"Zhang","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R60-20260422","doi-asserted-by":"crossref","first-page":"776","DOI":"10.4103\/ijo.IJO_913_19","article-title":"Intraoperative aberrometry in cataract surgery with topical versus peribulbar anesthesia","volume":"68","author":"Khokhar","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R61-20260422","first-page":"785","article-title":"Refractive development of the human eye","volume":"103","author":"Gordon","year":"1985","journal-title":"Arch Ophthalmol Chic Ill 1960"},{"key":"R62-20260422","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.ajo.2012.06.017","article-title":"Accuracy of intraocular lens power calculation formulae in children less than two years","volume":"154","author":"Nihalani","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R63-20260422","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1001\/archophthalmol.2011.358","article-title":"Predictability of IOL calculation and early refractive status in the infant Aphakia treatment study","volume":"130","author":"VanderVeen","year":"2012","journal-title":"Arch Ophthalmol"},{"key":"R64-20260422","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1001\/jamaophthalmol.2014.531","article-title":"Infant Aphakia Treatment Study Group. Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years","volume":"132","author":"Lambert","year":"2014","journal-title":"JAMA Ophthalmol"},{"issue":"Suppl 1","key":"R65-20260422","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/S0886-3350(97)80043-0","article-title":"Choice of lens and dioptric power in pediatric pseudophakia","volume":"23","author":"Dahan","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R66-20260422","first-page":"691","article-title":"[IOL calculations in cataract operations in children]","volume":"106","author":"Prost","year":"2004","journal-title":"Klin Oczna"},{"key":"R67-20260422","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/S0002-9394(98)00247-5","article-title":"Refractive changes after pediatric intraocular lens implantation","volume":"126","author":"Enyedi","year":"1998","journal-title":"Am J Ophthalmol"},{"key":"R68-20260422","doi-asserted-by":"crossref","first-page":"232","DOI":"10.4103\/tjosr.tjosr_105_18","article-title":"Pediatric intraocular lens power calculation","volume":"56","author":"Ganesh","year":"2018","journal-title":"TNOA Journal of Ophthalmic Science and Research"},{"key":"R69-20260422","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1067\/mpa.2002.126492","article-title":"Prospective analysis of pediatric pseudophakia: Myopic shift and postoperative outcomes","volume":"6","author":"Crouch","year":"2002","journal-title":"J Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R70-20260422","first-page":"20","article-title":"Paediatric ocular biometry and IOL power calculation","volume":"25","author":"Banerjee","year":"2020","journal-title":"Delhi Ophthalmological Society times"},{"key":"R71-20260422","first-page":"587","article-title":"Amblyopia in the phakic eye after unilateral congenital cataract extraction","volume":"10","author":"Ruth","year":"2006","journal-title":"J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R72-20260422","doi-asserted-by":"crossref","first-page":"e595","DOI":"10.1111\/aos.15805","article-title":"A new strategy to calculate the intraocular lens power in congenital cataracts according to age and axial length at implantation","volume":"102","author":"Dupessey","year":"2024","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"R73-20260422","first-page":"815","article-title":"Axial length development in children","volume":"12","author":"Bach","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"R74-20260422","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1016\/j.jcrs.2010.10.009","article-title":"Multifocal IOL implantation in children: Is the future clear?","volume":"36","author":"Rychwalski","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R75-20260422","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1016\/j.jcrs.2010.08.015","article-title":"Multifocal intraocular lenses for unilateral cataract in children","volume":"36","author":"Crist\u00f3bal","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R76-20260422","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1159\/000351653","article-title":"New-generation multifocal intraocular lens for pediatric cataract","volume":"230","author":"Abouzeid","year":"2013","journal-title":"Ophthalmologica"},{"key":"R77-20260422","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/j.jcrs.0000000000000705","article-title":"Comparative analysis of visual outcomes of multifocal and monofocal intraocular lenses in congenital cataract surgery","volume":"48","author":"Buzzonetti","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R78-20260422","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jcrs.2011.07.034","article-title":"Refractive shift in pseudophakic eyes during the second decade of life","volume":"38","author":"Trivedi","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R79-20260422","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1097\/j.jcrs.0000000000000283","article-title":"Visual outcomes after toric intraocular lens implantation in pediatric eyes undergoing cataract surgery","volume":"46","author":"Vasavada","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R80-20260422","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0002-9394(14)73753-5","article-title":"Cataract surgery and intraocular lens implantation in children","volume":"120","author":"Brady","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"R81-20260422","doi-asserted-by":"crossref","first-page":"22","DOI":"10.12809\/hkmj209241","article-title":"Ten-year refractive and visual outcomes of intraocular lens implantation in infants with congenital cataract","volume":"29","author":"Chan","year":"2023","journal-title":"Hong Kong Med J Xianggang Yi Xue Za Zhi"},{"key":"R82-20260422","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.ophtha.2016.12.040","article-title":"Myopic shift 5 years after intraocular lens implantation in the infant Aphakia treatment study","volume":"124","author":"Weakley","year":"2017","journal-title":"Ophthalmology"},{"key":"R83-20260422","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.4103\/0301-4738.149131","article-title":"Long-term results after primary intraocular lens implantation in children operated less than 2 years of age for congenital cataract","volume":"62","author":"Sukhija","year":"2014","journal-title":"Indian J Ophthalmol"},{"key":"R84-20260422","doi-asserted-by":"crossref","first-page":"1093276","DOI":"10.3389\/fmed.2022.1093276","article-title":"The impact of pre-operative axial length on myopic shift 3 years after congenital and developmental cataract surgery and intraocular lens implantation","volume":"9","author":"Zhou","year":"2022","journal-title":"Front Med"},{"key":"R85-20260422","doi-asserted-by":"crossref","first-page":"395","DOI":"10.2147\/OPTH.S152560","article-title":"Relationship between preoperative axial length and myopic shift over 3 years after congenital cataract surgery with primary intraocular lens implantation at the National Institute of Ophthalmology of Peru, 2007\u20132011","volume":"12","author":"Valera Cornejo","year":"2018","journal-title":"Clin Ophthalmol Auckl NZ"},{"key":"R86-20260422","first-page":"225","article-title":"Changes in interocular axial length after pediatric cataract surgery","volume":"11","author":"Trivedi","year":"2007","journal-title":"J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R87-20260422","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1016\/j.ajo.2004.06.068","article-title":"Rate of axial growth after congenital cataract surgery","volume":"138","author":"Vasavada","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"R88-20260422","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1038\/eye.2016.152","article-title":"Intraocular lens exchange for high myopia in pseudophakic children","volume":"30","author":"Kraus","year":"2016","journal-title":"Eye"},{"key":"R89-20260422","first-page":"238","article-title":"Pseudophakia and polypseudophakia in the first year of life","volume":"5","author":"Wilson","year":"2001","journal-title":"J AAPOS Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R90-20260422","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.4103\/ijo.IJO_2135_22","article-title":"The impact of COVID-19 on compliance to amblyopia treatment in a tertiary eye care center","volume":"71","author":"Hegde","year":"2023","journal-title":"Indian J Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1205_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:27:51Z","timestamp":1787837271000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1205_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,26]]},"references-count":89,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1205_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,26]]},"assertion":[{"value":"2024-05-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}