{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:20:28Z","timestamp":1787840428651,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>\n                      To compare the ease of visualization and comfort of the surgeon during phacoemulsification surgery using NGENUITY\n                      <jats:sup>\u00ae<\/jats:sup>\n                      3D (NG) visualization system and standard operating microscope (SOM).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective, randomized, single-blind, single-center study, patients undergoing phacoemulsification surgery by one of the five surgeons were randomly assigned to two groups based on the visualization modality\u2014NG and SOM. Ease of visualization and comfort of the surgeon was assessed using a 27-parameter in-house Surgeon Comfort Score questionnaire.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 224 phacoemulsification with intraocular lens implantations were performed in senile immature cataract (SIMC,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 174) and mature cataract patients (MC,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 50). Surgeon\u2019s ease of visualization (4.92\u20135.00) and hand\u2013eye coordination score (4.97\u20135.00) were comparable between the NG- and SOM-groups. Postoperative neck discomfort was lower in both the groups, with a relatively lower discomfort in the NG-group (score: 1.04 vs 1.56). The Spearman rank correlation coefficient (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      ) between illumination of the operation theatre room and the surgical field revealed a weak negative correlation for most of the patients in the NG-group, and a positive correlation for patients in the SOM-group. No correlation was obtained between brightness of the surgical field and comfort with the surgical field brightness.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Similar ease of visualization was experienced by the surgeons using NG- and SOM-system. Neck discomfort postsurgery was numerically lower in the NG-group, although not significant. Additionally, the NG-system permitted the safe performance of phacoemulsification using a lower surgical field illumination.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1332_23","type":"journal-article","created":{"date-parts":[[2023,12,22]],"date-time":"2023-12-22T01:06:03Z","timestamp":1703207163000},"page":"56-62","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["3D visualization system and standard operating microscope for ease of visualization and surgeon comfort during phacoemulsification surgery"],"prefix":"10.4103","volume":"72","author":[{"given":"Naren","family":"Shetty","sequence":"first","affiliation":[{"name":"Cataract Department, Narayana Nethralaya, Rajajinagar, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"family":"Aishwarya","sequence":"additional","affiliation":[{"name":"Cataract Department, Narayana Nethralaya, Rajajinagar, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohitha P","family":"Nayak","sequence":"additional","affiliation":[{"name":"Cataract Department, Narayana Nethralaya, Rajajinagar, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luci","family":"Kaweri","sequence":"additional","affiliation":[{"name":"Cataract Department, Narayana Nethralaya, Rajajinagar, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravi Krishna","family":"Kanaradi","sequence":"additional","affiliation":[{"name":"Cataract Department, Narayana Nethralaya, Rajajinagar, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anchana A","family":"Pisharody","sequence":"additional","affiliation":[{"name":"Imaging Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya, Bommasandra, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,12,22]]},"reference":[{"key":"R1-20260508","doi-asserted-by":"crossref","first-page":"xxx","DOI":"10.1016\/j.ajo.2018.04.014","article-title":"Phaco-emulsification and aspiration: A new technique of cataract removal: A preliminary report","volume":"191","author":"Kelman","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R3-20260508","doi-asserted-by":"crossref","first-page":"797","DOI":"10.5301\/ejo.5001004","article-title":"Phacoemulsification outcomes with different illumination techniques","volume":"27","author":"Yepez","year":"2017","journal-title":"Eur J Ophthalmol"},{"key":"R4-20260508","first-page":"34","article-title":"Digital vs analog surgical visualization for vitreoretinal surgery","volume":"14","author":"Franklin","year":"2017","journal-title":"Retin Physician"},{"key":"R5-20260508","doi-asserted-by":"crossref","first-page":"4499","DOI":"10.2147\/OPTH.S327570","article-title":"Comparison of 3D digitally assisted visualization system with current standard visualization for the removal of vitreous in a preclinical model","volume":"15","author":"Mura","year":"2021","journal-title":"Clin Ophthalmol"},{"key":"R6-20260508","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/IIO.0000000000000291","article-title":"3D surgical viewing systems in vitreoretinal surgery","volume":"60","author":"Agranat","year":"2020","journal-title":"Int Ophthalmol Clin"},{"key":"R8-20260508","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1097\/IAE.0000000000002018","article-title":"3D surgical viewing system in ophthalmology: Perceptions of the surgical team","volume":"38","author":"Rizzo","year":"2018","journal-title":"Retina"},{"key":"R9-20260508","doi-asserted-by":"crossref","first-page":"318","DOI":"10.3928\/1081597X-20190410-02","article-title":"Heads-up Cataract Surgery: Complication Rates, Surgical Duration, and Comparison With Traditional Microscopes","volume":"35","author":"Weinstock","year":"2019","journal-title":"J Refract Surg"},{"key":"R10-20260508","doi-asserted-by":"crossref","first-page":"318","DOI":"10.3928\/1081597X-20190410-02","article-title":"Heads-up cataract surgery: Complication rates, surgical duration, and comparison with traditional microscopes","volume":"35","author":"Weinstock","year":"2019","journal-title":"J Refract Surg (Thorofare, NJ: 1995)"},{"key":"R11-20260508","doi-asserted-by":"crossref","first-page":"341","DOI":"10.4103\/ijo.IJO_1012_18","article-title":"Three-dimensional digital visualization of phacoemulsification and intraocular lens implantation","volume":"67","author":"Qian","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"R12-20260508","first-page":"229","article-title":"Lights-out surgery for strabismus using a heads-up 3D vision system","volume":"73","author":"Hamasaki","year":"2019","journal-title":"Acta Med Okayama"},{"key":"R13-20260508","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.1097\/IAE.0000000000001420","article-title":"Minimal endoillumination levels and display luminous emittance during three-dimensional heads-up vitreoretinal surgery","volume":"37","author":"Adam","year":"2017","journal-title":"Retina"},{"key":"R14-20260508","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/IAE.0000000000000689","article-title":"Heads-up surgery for vitreoretinal procedures: An experimental and clinical study","volume":"36","author":"Eckardt","year":"2016","journal-title":"Retina"},{"key":"R15-20260508","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1177\/1120672120929962","article-title":"Comparison of microscopic illumination between a three-dimensional heads-up system and eyepiece in cataract surgery","volume":"31","author":"Nariai","year":"2021","journal-title":"Eur J Ophthalmol"},{"key":"R16-20260508","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/j.jcrs.0000000000000448","article-title":"Efficacy of 3D digital visualization in minimizing coaxial illumination and phototoxic potential in cataract surgery: Pilot study","volume":"47","author":"Rosenberg","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R17-20260508","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/ICB.0000000000000486","article-title":"Heads-up digitally assisted surgical viewing for retinal detachment repair in a patient with severe kyphosis","volume":"12","author":"Skinner","year":"2018","journal-title":"Retin Cases Brief Rep"},{"key":"R18-20260508","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.oret.2018.10.016","article-title":"Comparison of a three-dimensional heads-up display surgical platform with a standard operating microscope for macular surgery","volume":"3","author":"Talcott","year":"2019","journal-title":"Ophthalmol Retina"},{"key":"R19-20260508","doi-asserted-by":"crossref","first-page":"2304","DOI":"10.4103\/ijo.IJO_231_21","article-title":"Initial experience with three-dimensional heads-up display system for cataract surgery - A comparative study","volume":"69","author":"Kelkar","year":"2021","journal-title":"Indian J Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1332_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:22:24Z","timestamp":1787836944000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1332_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,22]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1332_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,22]]},"assertion":[{"value":"2023-05-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-08-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}