{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:40:25Z","timestamp":1787071225968,"version":"build-2736575974"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T00:00:00Z","timestamp":1774483200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This comparative study aimed to evaluate interchangeability of the Myopia Master, IOL Master 700, and Nidek ARK500 autorefractometer for axial length, keratometry, and autorefraction measurements among myopic children.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective, observational, single-blinded study included children aged 5 to 15 years, with myopia \u2265-0.5D. The axial length and keratometry were measured using Myopia Master and IOL Master 700. Cycloplegic autorefraction with keratometry was measured using Myopia Master and NIDEK ARK500 autorefractor. The primary outcome was to assess the agreement of measurements between the devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 35 participants with a mean age of 10.2 \u00b1 2.8 years (57% male) were enrolled. The Myopia Master measured axial length 0.01 mm shorter and keratometry 0.087 D and 0.12 D flatter in the two meridians compared to the IOL Master 700. The spherical refractive error was 0.086 D more myopic than that from the NIDEK ARK500 autorefractometer, while cylindrical error showed no difference. All parameters demonstrated strong correlations (r: 0.96\u20130.99).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The Myopia Master is interchangeable with the NIDEK ARK500 autorefractometer for refractive error assessment and with the IOL Master 700 for keratometry and axial length measurements in pediatric myopic subjects. This is supported by minimal mean bias and narrow 95% limits of agreement. Thus, it could serve as reliable tool for myopia management.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1476_25","type":"journal-article","created":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T10:00:16Z","timestamp":1774519216000},"page":"576-579","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of ocular biometry and refraction measurements among myopic children using myopia master with IOL master 700 and NIDEK ARK-500 autorefractor"],"prefix":"10.4103","volume":"74","author":[{"given":"Vinay","family":"Gupta","sequence":"first","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber Amar","family":"Bhayana","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jyoti","family":"Rawat","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhyuday","family":"Saxena","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebika","family":"Dhiman","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swati","family":"Phuljhele","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Saxena","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,26]]},"reference":[{"key":"R1-20260416","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"R2-20260416","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1111\/j.1475-1313.2005.00298.x","article-title":"Myopia and associated pathological complications","volume":"25","author":"Saw","year":"2005","journal-title":"Ophthalmic Physiol Opt"},{"key":"R3-20260416","first-page":"CD014758","article-title":"Interventions for myopia control in children: A living systematic review and network meta-analysis","volume":"2","author":"Lawrenson","year":"2025","journal-title":"Cochrane Database Syst Rev"},{"key":"R4-20260416","doi-asserted-by":"crossref","first-page":"M184","DOI":"10.1167\/iovs.18-25977","article-title":"IMI - Clinical management guidelines report","volume":"60","author":"Gifford","year":"2019","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R5-20260416","doi-asserted-by":"crossref","first-page":"1406","DOI":"10.1111\/opo.13192","article-title":"Effect of low-dose atropine (0.01%) on crystalline lens power among school-aged children with progressive myopia","volume":"43","author":"Saxena","year":"2023","journal-title":"Ophthalmic Physiol Opt"},{"key":"R6-20260416","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1111\/opo.12918","article-title":"An evaluation of the IOLMaster 700 and its agreement with the IOLMaster v3 in children","volume":"42","author":"Leighton","year":"2022","journal-title":"Ophthalmic Physiol Opt"},{"key":"R7-20260416","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1097\/OPX.0000000000001113","article-title":"Comparison of refractive measures of three autorefractors in children and adolescents","volume":"94","author":"Xiong","year":"2017","journal-title":"Optom Vis Sci"},{"key":"R8-20260416","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1186\/s12886-022-02672-9","article-title":"Accuracy of axial length, keratometry, and refractive measurement with myopia master in children with ametropia","volume":"22","author":"Ye","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"R9-20260416","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1111\/opo.13101","article-title":"Comparing ocular biometry and autorefraction measurements from the myopia master with the IOLMaster 700 and the Huvitz HRK-8000A autorefractor","volume":"43","author":"Pedersen","year":"2023","journal-title":"Ophthalmic Physiol Opt"},{"key":"R10-20260416","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.ajo.2016.06.020","article-title":"Agreement between swept-source optical biometry and scheimpflug-based topography measurements of anterior segment parameters","volume":"169","author":"\u00d6zyol","year":"2016","journal-title":"Am J Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1476_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:43:20Z","timestamp":1787067800000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1476_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,26]]},"references-count":10,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1476_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,26]]},"assertion":[{"value":"2025-06-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}