{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:24:38Z","timestamp":1787765078637,"version":"build-2784847793"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:p>Slit lamp biomicroscope is the right hand of an Ophthalmologist. Even though precise, its bulky design and complex working process are limiting constraints, making it difficult for screening at outreach camps, which are an integral part of this field for the purpose of eliminating needless blindness. The torchlight is the main tool used for screening. Recently, the integration of smartphones with instruments and the digitization of slit lamp has been explored, to provide simple and easy hacks. By bringing the slit of the slit lamp to traditional torchlight, we have created \u201cThe Slitscope\u201d. It combines the best of both worlds as a simple innovative do-it-yourself novel technique for precise cataract screening. It is especially useful in peripheral centers, vision centers, and outreach camps. We present two prototypes which can also be 3D printed.<\/jats:p>","DOI":"10.4103\/ijo.ijo_1589_23","type":"journal-article","created":{"date-parts":[[2024,1,8]],"date-time":"2024-01-08T10:01:19Z","timestamp":1704708079000},"page":"741-744","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["The Slitscope"],"prefix":"10.4103","volume":"72","author":[{"given":"Prithvi","family":"Chandrakanth","sequence":"first","affiliation":[{"name":"Department of Vitreoretinal Services, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John Davis","family":"Akkara","sequence":"additional","affiliation":[{"name":"Department of Glaucoma Services, Chaitanya Eye Hospital and Westend Eye Hospital, Kochi, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saloni M","family":"Joshi","sequence":"additional","affiliation":[{"name":"Department of General Ophthalmology, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirika","family":"Gosalia","sequence":"additional","affiliation":[{"name":"Department of General Ophthalmology, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K S","family":"Chandrakanth","sequence":"additional","affiliation":[{"name":"Chief Medical Officer, General Ophthalmology, Dr. Chandrakanth Nethralaya, Kozhikode, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V","family":"Narendran","sequence":"additional","affiliation":[{"name":"Department of Vitreoretinal Services, Aravind Eye Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,8]]},"reference":[{"key":"R1-20260504","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/IIO.0000000000000298","article-title":"A (eye): A review of current applications of artificial intelligence and machine learning in ophthalmology","volume":"60","author":"Armstrong","year":"2020","journal-title":"Int Ophthalmol Clin"},{"key":"R2-20260504","doi-asserted-by":"crossref","first-page":"1037689.","DOI":"10.1155\/2020\/1037689","article-title":"Portable handheld slit-lamp based on a smartphone camera for cataract screening","volume":"2020","author":"Hu","year":"2020","journal-title":"J Ophthalmol"},{"key":"R3-20260504","doi-asserted-by":"crossref","first-page":"1690","DOI":"10.4103\/ijo.IJO_52_19","article-title":"Anterior segment photography with intraocular lens","volume":"67","author":"Chandrakanth","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"R4-20260504","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.4103\/ijo.IJO_2988_21","article-title":"Anterior segment photography with intraocular lens (ASPI)-An innovative resident education tool","volume":"70","author":"Gosalia","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"R5-20260504","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.4103\/ijo.IJO_3707_20","article-title":"A novel approach to anterior segment imaging with smartphones in the COVID-19 era","volume":"69","author":"Dutt","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R6-20260504","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1080\/08820538.2021.1887899","article-title":"Anterior segment imaging devices in ophthalmic telemedicine","volume":"36","author":"Armstrong","year":"2021","journal-title":"Semin Ophthalmol"},{"key":"R7-20260504","doi-asserted-by":"crossref","first-page":"576.","DOI":"10.3390\/diagnostics10080576","article-title":"Evaluation of nuclear cataract with smartphone-attachable slit-lamp device","volume":"10","author":"Yazu","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"R8-20260504","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1111\/cxo.12381","article-title":"Tele-manufactured affordable smartphone anterior segment microscope","volume":"99","author":"Chiong","year":"2016","journal-title":"Clin Exp Optom"},{"key":"R9-20260504","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The lens opacities classification system III. The longitudinal study of cataract study group","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1589_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:00:01Z","timestamp":1787763601000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1589_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,8]]},"references-count":9,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1589_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,8]]},"assertion":[{"value":"2023-06-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-10-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}