{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:23:06Z","timestamp":1787764986450,"version":"build-2784847793"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To study the correlation of corneal topography, corneal biomechanical properties, and ocular aberrations with the magnitude of refractive error in myopic eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>All myopic patients attending the clinic for refractive surgery were recruited. Data recorded included visual acuity, axial length (AL), central corneal thickness (CCT), manifest refraction spherical equivalent (MRSE), topography (Pentacam \u2013 Oculus), corneal biomechanical factors [ocular response analyzer (ORA)], and optical aberrations (iTrace). They were further categorized into group 1 (suitable for femto-LASIK) and group 2 (unsuitable for femto-LASIK).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Sixty eyes (30 myopes) of mean age 22.78 \u00b1 2.71 years were enrolled. A negative correlation of refractive error was noted with AL (\u03c1 = \u22120.9;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), total aberrations (\u03c1 = 0.53;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and lower-order aberrations (LOA) (\u03c1 = 0.54;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). A strongly positive correlation was noted between CCT and corneal hysteresis (CH) (\u03c1 = 0.63;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), CCT and CRF (\u03c1 = 0.56;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), CH and corneal resistance factor (CRF) (\u03c1 = 0.83;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and Goldmann equivalent intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) (\u03c1 = 0.78;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). An increase in higher-order aberrations (HOAs) as well as lower-order aberrations (LOAs) was noted with increasing sim-K [HOA (r = 0.73,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001); LOA (r = 0.601,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.014)] and increasing CRF [HOA (r = 0.5,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.006); LOA (r = 0.732,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001)] in group 2. The amount of refractive error, axial length, central corneal thickness, and sim-K were significantly different in the two groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Increasing degree of myopia is associated with an increase in axial length, total aberrations, and lower-order aberrations. Corneal biomechanical parameters have a strong correlation with each other. Lower corneal biomechanics are noted in high myopes as they have weaker and thinner corneas. Corneal biomechanics and ocular aberrations do not differ significantly between cases suitable for femto-LASIK and cases unsuitable for femto-LASIK.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1627_23","type":"journal-article","created":{"date-parts":[[2023,12,15]],"date-time":"2023-12-15T05:00:15Z","timestamp":1702616415000},"page":"538-543","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical properties of cornea and ocular aberrations in myopic eyes"],"prefix":"10.4103","volume":"72","author":[{"given":"Rebika","family":"Dhiman","sequence":"first","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Divya","family":"Singh","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Murugesan","family":"Vanathi","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Radhika","family":"Tandon","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karthikeyan","family":"Mahalingam","sequence":"additional","affiliation":[{"name":"Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,12,15]]},"reference":[{"key":"R1-20260504","doi-asserted-by":"crossref","first-page":"e0271736","DOI":"10.1371\/journal.pone.0271736","article-title":"Blindness and visual impairment and their causes in India: Results of a nationally representative survey","volume":"17","author":"Vashist","year":"2022","journal-title":"PLoS One"},{"key":"R2-20260504","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/S0002-9394(99)00444-4","article-title":"Myopia and vision 2020","volume":"129","author":"McCarty","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"R3-20260504","first-page":"723.","article-title":"The epidemiology of high myopia-chanding trends","volume":"31","author":"Jain","year":"1983","journal-title":"Indian J Ophthalmol"},{"key":"R4-20260504","first-page":"623","article-title":"Refractive error in children in an urban population in New Delhi","volume":"43","author":"Murthy","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R5-20260504","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.4103\/ijo.IJO_112_21","article-title":"Prevalence of refractive errors among the school-going children in East Sikkim","volume":"69","author":"Bhutia","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R6-20260504","doi-asserted-by":"crossref","first-page":"547","DOI":"10.18535\/jmscr\/v6i12.87","article-title":"Prevalence of refractive error among college students in South India: A pilot study","volume":"6","author":"Chelliah","year":"2018","journal-title":"J Med Sci Clin Res"},{"key":"R7-20260504","first-page":"2266.","article-title":"Methodology for cornea compensated IOP and corneal resistance factor for the Reichert ocular response analyzer","volume":"47","author":"Luce","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R8-20260504","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer","volume":"31","author":"Luce","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260504","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/S0042-6989(02)00035-4","article-title":"Wavefront aberrations in eyes of emmetropic and moderately myopic school children and young adults","volume":"42","author":"He","year":"2002","journal-title":"Vision Res"},{"key":"R10-20260504","doi-asserted-by":"crossref","first-page":"23.","DOI":"10.1167\/9.1.23","article-title":"Monochromatic aberrations in hyperopic and emmetropic children","volume":"9","author":"Martinez","year":"2009","journal-title":"J Vis"},{"key":"R11-20260504","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1167\/iovs.10-5841","article-title":"Evaluation of the comparability and repeatability of four wavefront aberrometers","volume":"52","author":"Visser","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R12-20260504","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1136\/bjo.85.8.916","article-title":"The cornea in young myopic adults","volume":"85","author":"Chang","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"R13-20260504","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1136\/bjo.2006.101170","article-title":"Central corneal thickness and its relationship to myopia in Chinese adults","volume":"90","author":"Fam","year":"2006","journal-title":"Br J Ophthalmol"},{"key":"R14-20260504","doi-asserted-by":"crossref","first-page":"595330","DOI":"10.3389\/fbioe.2020.595330","article-title":"Corneal biomechanical properties in varying severities of myopia","volume":"8","author":"Sedaghat","year":"2020","journal-title":"Front Bioeng Biotechnol"},{"key":"R15-20260504","doi-asserted-by":"crossref","first-page":"459.","DOI":"10.1186\/s12886-020-01729-x","article-title":"Effect of biomechanical properties on myopia: A study of new corneal biomechanical parameters","volume":"20","author":"Han","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"R16-20260504","doi-asserted-by":"crossref","first-page":"2357","DOI":"10.3390\/diagnostics11122357","article-title":"Association of corneal biomechanics properties with myopia in a child and a parent cohort: Hong Kong children eye study","volume":"11","author":"Tang","year":"2021","journal-title":"Diagnostics"},{"key":"R17-20260504","doi-asserted-by":"crossref","first-page":"e2793516","DOI":"10.1155\/2016\/2793516","article-title":"Corneal biomechanics determination in healthy myopic subjects","volume":"2016","author":"Qiu","year":"2016","journal-title":"J Ophthalmol"},{"key":"R18-20260504","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1016\/j.visres.2008.06.020","article-title":"Biomechanical properties of the cornea in high myopia","volume":"48","author":"Shen","year":"2008","journal-title":"Vision Res"},{"key":"R19-20260504","first-page":"1083","article-title":"Association between corneal biomechanical properties and myopia in Chinese subjects","volume":"25","author":"Jiang","year":"2011","journal-title":"Eye Lond Engl"},{"key":"R20-20260504","doi-asserted-by":"crossref","first-page":"553","DOI":"10.3109\/02713683.2012.669007","article-title":"Identification of biomechanical properties of the cornea: The ocular response analyzer","volume":"37","author":"Terai","year":"2012","journal-title":"Curr Eye Res"},{"key":"R21-20260504","first-page":"E803","article-title":"Relative importance of factors affecting corneal hysteresis measurement","volume":"89","author":"Sullivan-Mee","year":"2012","journal-title":"Optom Vis Sci Off Publ Am Acad Optom"},{"key":"R22-20260504","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1016\/j.jcrs.2013.12.019","article-title":"Corneal resistance factor and corneal hysteresis in a 6- to 18-year-old population","volume":"40","author":"Hashemi","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R23-20260504","doi-asserted-by":"crossref","first-page":"507.","DOI":"10.1097\/OPX.0000000000000231","article-title":"Relationship among corneal biomechanics, refractive error, and axial length","volume":"91","author":"Bueno-Gimeno","year":"2014","journal-title":"Optom Vis Sci"},{"key":"R24-20260504","doi-asserted-by":"crossref","first-page":"3852","DOI":"10.1167\/iovs.07-1670","article-title":"Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children","volume":"49","author":"Lim","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R25-20260504","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1111\/j.1475-1313.2011.00852.x","article-title":"Corneal biomechanical properties measured with the Ocular Response Analyser in a myopic population","volume":"31","author":"Plakitsi","year":"2011","journal-title":"Ophthalmic Physiol Opt"},{"key":"R26-20260504","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1111\/j.1444-0938.2011.00696.x","article-title":"Corneal biomechanical properties and their correlates with refractive error","volume":"95","author":"Radhakrishnan","year":"2012","journal-title":"Clin Exp Optom"},{"key":"R27-20260504","doi-asserted-by":"crossref","first-page":"905129","DOI":"10.1155\/2014\/905129","article-title":"Assessment of corneal biomechanical properties and intraocular pressure in myopic Spanish healthy population","volume":"2014","author":"Del Buey","year":"2014","journal-title":"J Ophthalmol"},{"key":"R28-20260504","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.ophtha.2010.12.001","article-title":"Determinants of corneal biomechanical properties in an adult Chinese population","volume":"118","author":"Narayanaswamy","year":"2011","journal-title":"Ophthalmology"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1627_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:53:26Z","timestamp":1787763206000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1627_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,15]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1627_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,15]]},"assertion":[{"value":"2023-06-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-09-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}