{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:29:58Z","timestamp":1787840998919,"version":"build-2784847793"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T00:00:00Z","timestamp":1767744000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:p>To describe a surgical technique using a three-flanged Prolene suture for managing zonular dialysis during cataract surgery in a patient with preoperative zonular deficiency in brown cataract. A patient with zonular deficiency and brown cataract underwent cataract surgery complicated by zonular dialysis between the 4 o\u2019clock and 8 o\u2019clock positions. A three-flanged Prolene suture, fashioned in an iris hook-like configuration, was used. A 26-gauge needle was introduced at the 6 o\u2019clock position to pass a 7-0 Prolene suture through the zonular defect. A capsular tension ring (CTR) was placed to stabilize the anterior capsule, and the Prolene suture was engaged at the dialysis site. The suture was cut, cauterized, and buried under the conjunctiva. An intraocular lens was implanted in the capsular bag. Postoperative visual acuity was 6\/9, and intraocular pressure was normal. There were no intraoperative complications. The zonular dialysis was effectively managed, and the Intraocular lens (IOL) remained stable. The three-flanged Prolene suture technique is an effective method for managing zonular instability during cataract surgery. Combined with a CTR, it ensures capsule stabilization and IOL positioning, providing reliable outcomes in cases of zonular deficiency, including subluxated cataracts and intraoperative zonular dehiscence.<\/jats:p>","DOI":"10.4103\/ijo.ijo_1672_25","type":"journal-article","created":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T12:00:31Z","timestamp":1767787231000},"page":"589-591","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Three-flanged capsular hook for zonular dialysis repair"],"prefix":"10.4103","volume":"74","author":[{"given":"Anjali","family":"Khadia","sequence":"first","affiliation":[{"name":"Pediatric Opthhalmology Services, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swati","family":"Upadhyaya","sequence":"additional","affiliation":[{"name":"Glaucoma Services, Aravind Eye Hospital Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rengaraj","family":"Venkatesh","sequence":"additional","affiliation":[{"name":"Glaucoma Services, Aravind Eye Hospital Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fredrick","family":"Moutappa","sequence":"additional","affiliation":[{"name":"Pediatric Opthhalmology Services, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arpit","family":"Gupta","sequence":"additional","affiliation":[{"name":"General Opthalmology, Aravind Eye Hopital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prajakta","family":"Thakur","sequence":"additional","affiliation":[{"name":"Pediatric Opthhalmology Services, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nishant","family":"Maindargi","sequence":"additional","affiliation":[{"name":"General Opthalmology, Aravind Eye Hopital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kannusamy","family":"Veena","sequence":"additional","affiliation":[{"name":"Pediatric Opthhalmology Services, Aravind Eye Hospital, Pondicherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,1,7]]},"reference":[{"key":"R1-20260416","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/ICU.0000000000000118","article-title":"All about capsular tension rings","volume":"26","author":"Weber","year":"2015","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20260416","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.2147\/OPTH.S244751","article-title":"Double-flanged polypropylene suture for scleral fixation of Cionni capsule tension ring","volume":"14","author":"Samir","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"R3-20260416","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/j.jcrs.0000000000000116","article-title":"Novel double-flanged technique for managing Marfan syndrome and microspherophakia","volume":"46","author":"Canabrava","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R4-20260416","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/ICU.0b013e3282f2ccc8","article-title":"Surgical strategies for the management of zonular compromise","volume":"19","author":"Blecher","year":"2008","journal-title":"Curr Opin Ophthalmol"},{"key":"R5-20260416","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/S0886-3350(98)80218-6","article-title":"Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation","volume":"24","author":"Cionni","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R6-20260416","first-page":"507","article-title":"Capsular tension rings: Update on endocapsular support devices","volume":"19","author":"Hasanee","year":"2006","journal-title":"Ophthalmol Clin North Am"},{"key":"R7-20260416","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1097\/j.jcrs.0000000000000985","article-title":"Flanged iris hook for capsular bag stabilization","volume":"48","author":"Soyler","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R8-20260416","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jcrs.2011.12.001","article-title":"Glued endocapsular hemi-ring segment for fibrin glue-assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses","volume":"38","author":"Jacob","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260416","doi-asserted-by":"crossref","first-page":"1958","DOI":"10.1016\/j.jcrs.2014.10.009","article-title":"Glued capsular hook: Technique for fibrin glue-assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses","volume":"40","author":"Jacob","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R10-20260416","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1016\/j.jcrs.2019.08.001","article-title":"Repairing iridodialysis by riveting with a double-flanged polypropylene suture","volume":"45","author":"Kusaka","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260416","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/j.jcrs.0000000000000823","article-title":"In-N-Out technique: Double-flanged suture ab interno iridodialysis repair","volume":"48","author":"Rosenberg","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260416","doi-asserted-by":"crossref","first-page":"1084538","DOI":"10.3389\/fmed.2022.1084538","article-title":"Case report: Double-armed flanged polypropylene suture for repairing wide iridodialysis","volume":"9","author":"Peng","year":"2023","journal-title":"Front Med (Lausanne)"},{"key":"R13-20260416","doi-asserted-by":"crossref","first-page":"2257","DOI":"10.4103\/IJO.IJO_2879_22","article-title":"A novel transconjunctival, intrascleral, ab-externo, knotless, and double-flanged technique with 6-0 Prolene for iridodialysis repair","volume":"71","author":"Ramakrishnan","year":"2023","journal-title":"Indian J Ophthalmol"},{"key":"R14-20260416","doi-asserted-by":"crossref","first-page":"2653","DOI":"10.1007\/s10792-017-0746-5","article-title":"Double-flanged-haptic and capsular tension ring or segment for sutureless fixation in zonular instability","volume":"38","author":"Canabrava","year":"2018","journal-title":"Int Ophthalmol"},{"key":"R15-20260416","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1097\/j.jcrs.0000000000000260","article-title":"Adjustable 6 and 0 polypropylene flanged technique for scleral fixation. Part 1: Primary fixation IOLs in aphakia, capsular stabilizing devices, and aniridia implants","volume":"46","author":"Assia","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R16-20260416","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.4103\/IJO.IJO_2885_24","article-title":"Dumbbell technique for iridodialysis repair","volume":"73","author":"Khadia","year":"2025","journal-title":"Indian J Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1672_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:39:52Z","timestamp":1787837992000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1672_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,7]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1672_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,7]]},"assertion":[{"value":"2025-07-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}