{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:35:53Z","timestamp":1786649753281,"version":"build-2736575974"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the accuracy in astigmatism reduction by using IOLM 700 steep total keratometry (TK) axis, Berdahl and Hardten astigmatism fix, and Barrett Rx formula following misaligned toric intraocular lens (IOL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Ten patients with residual refractive astigmatism due to misalignment following toric IOL implantation were included in this retrospective study. They were analyzed at days 4, 7\/8, and 10\/11 following primary cataract surgery on the platform of Berdahl and Hardten astigmatism fix, Barrett Rx formula, and IOLM 700 to determine the optimum axis of repositioning, and underwent IOL realignment on the steep TK axis of IOLM 700 assisted by the Callisto eye. The final outcome parameters were subjective refraction and orientation of toric IOL assessed 22 \u00b1 1 days following repositioning surgery. These parameters were fed in the Barrett Rx formula and its vector analysis graph was utilized to determine the predicted ideal axis with the least residual astigmatism and the estimated residual astigmatism if the toric IOL was realigned according to the axis suggested by Berdahl and Hardten astigmatism fix and Barrett Rx formula.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Realigning the toric IOL on IOLM 700 steep TK axis along with the Callisto eye reduces the residual refractive astigmatism significantly (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003) from 2.00 \u00b1 0.78 D to 0.18 \u00b1 0.12 D (90.5 \u00b1 7.6%) in comparison to the estimated 0.57 \u00b1 0.31 D (68.4 \u00b1 21.9%) by Berdahl and Hardten astigmatism fix and 0.61 \u00b1 0.33 D (66.4 \u00b1 23.5%) by Barrett Rx formula.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Realigning the misaligned toric IOL on the IOLM 700 steep TK axis gives a better reduction in the residual refractive astigmatism in comparison to Berdahl and Hardten astigmatism fix and Barrett Rx formula.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1760_21","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T07:51:02Z","timestamp":1644997862000},"page":"413-419","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Comparing IOLM700 TK, Berdahl and Hardten astigmatism fix calculator and Barrett Rx formula in managing residual astigmatism due to toric intraocular lens misalignment"],"prefix":"10.4103","volume":"70","author":[{"given":"Ajay C","family":"Sharma","sequence":"first","affiliation":[{"name":"Medical Director, Amber Eye Care and Microsurgery Centre, Thane West, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Avani","family":"Khetan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Amber Eye Care and Microsurgery Centre, Thane West, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,27]]},"reference":[{"key":"R1-20251006","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","article-title":"Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes","volume":"36","author":"Hoffmann","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R2-20251006","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","article-title":"Toric intraocular lenses in the correction of astigmatism during cataract surgery: A systematic review and meta-analysis","volume":"123","author":"Kessel","year":"2016","journal-title":"Ophthalmology"},{"key":"R3-20251006","doi-asserted-by":"crossref","first-page":"394","DOI":"10.3928\/1081597X-20140429-01","article-title":"Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation","volume":"30","author":"Hirnschall","year":"2014","journal-title":"J Refract Surg"},{"key":"R4-20251006","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.jcrs.2011.04.036","article-title":"Residual astigmatism produced by toric intraocular lens rotation","volume":"37","author":"Felipe","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R5-20251006","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jfo.2017.11.002","article-title":"Toric lens implantation in cataract surgery: Automated versus manual horizontal axis marking, analysis of 50 cases","volume":"41","author":"Raucau","year":"2018","journal-title":"J Fr Ophtalmol"},{"key":"R6-20251006","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1016\/j.jcrs.2019.03.030","article-title":"Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking","volume":"45","author":"Zhou","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R7-20251006","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1016\/j.ophtha.2017.05.025","article-title":"Axis misalignment of toric intraocular lens: Placement error and postoperative rotation","volume":"124","author":"Inoue","year":"2017","journal-title":"Ophthalmology"},{"key":"R8-20251006","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.jcrs.2014.01.044","article-title":"Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism","volume":"40","author":"Miyake","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R9-20251006","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.jcrs.2011.08.028","article-title":"Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bag","volume":"38","author":"Shah","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R10-20251006","doi-asserted-by":"crossref","first-page":"2683","DOI":"10.1016\/j.jcrs.2015.07.036","article-title":"Randomized controlled clinical trial to evaluate different intraocular lenses for the surgical compensation of low to moderate-to-high regular corneal astigmatism during cataract surgery","volume":"41","author":"Emesz","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R11-20251006","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","article-title":"Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery","volume":"45","author":"Wang","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R12-20251006","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.jcrs.2016.01.038","article-title":"Biometry with a new swept-source optical coherence tomography biometer: repeatability and agreement with an optical low-coherence reflectometry device","volume":"42","author":"Kurian","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R13-20251006","doi-asserted-by":"crossref","first-page":"071412","DOI":"10.1117\/1.JBO.19.7.071412","article-title":"Optical coherence tomography today: Speed, contrast, and multimodality","volume":"19","author":"Drexler","year":"2014","journal-title":"J Biomed Opt"},{"key":"R14-20251006","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1038\/eye.2013.209","article-title":"The effect of head tilt on keratometric measurement using the IOL Master","volume":"27","author":"Park","year":"2013","journal-title":"Eye (Lond)"},{"key":"R15-20251006","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation","volume":"34","author":"Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R16-20251006","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1016\/j.jcrs.2009.02.035","article-title":"Repositioning technique and rate for toric intraocular lenses","volume":"35","author":"Chang","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R17-20251006","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/00055735-200002000-00007","article-title":"Astigmatism and toric intraocular lenses","volume":"11","author":"Novis","year":"2000","journal-title":"Curr Opin Ophthalmol"},{"key":"R18-20251006","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ophtha.2017.07.004","article-title":"Incidence and outcomes of repositioning surgery to correct misalignment of toric intraocular lenses","volume":"125","author":"Oshika","year":"2018","journal-title":"Ophthalmology"},{"key":"R19-20251006","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1016\/j.jcrs.2016.09.017","article-title":"Residual astigmatism after toric intraocular lens implantation: Analysis of data from an online toric intraocular lens back-calculator","volume":"42","author":"Kramer","year":"2016","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_1760_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:58:02Z","timestamp":1786647482000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_1760_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,27]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1760_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,27]]},"assertion":[{"value":"2021-07-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-09-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}