{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:43:50Z","timestamp":1786653830524,"version":"build-2736575974"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Optical properties of commonly used multifocal and extended-depth-of-focus (EDOF) intraocular lenses (IOLs) can induce artifacts or changes in optical coherence tomography (OCT) measurements. Our purpose was to investigate the possible effects of different IOLs on peripapillary and macular OCT parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The preoperative and postoperative third-month peripapillary OCT and ganglion cell analysis (GCA) parameters of patients having monofocal (Alcon IQ), multifocal (PanOptix), or EDOF (Vivity) IOL implanted during cataract surgery were compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Sixty-four eyes of 64 patients were included (21 monofocal, 24 multifocal, and 19 EDOF). Although all OCT image qualities increased postoperatively, only GCA image quality changes in the monofocal and multifocal groups reached statistical significance. Most peripapillary retinal nerve fiber layer (RNFL) and GCA parameters were similar preoperatively and postoperatively. The superior RNFL thickness in the monofocal group and the temporal RNFL thickness in the EDOF group were higher postoperatively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.04 and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.02, respectively). Most GCA and RNFL value changes between preoperative and postoperative measurements were similar between groups. In the parameters that changed, postoperative values were higher in the monofocal group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.02 for minimum ganglion cell layer and inner plexiform layer,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.04 for average RNFL).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Trifocal and EDOF IOLs do not seem to have a negative effect on OCT parameters.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_1938_23","type":"journal-article","created":{"date-parts":[[2024,2,6]],"date-time":"2024-02-06T01:00:33Z","timestamp":1707181233000},"page":"S423-S428","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters"],"prefix":"10.4103","volume":"72","author":[{"given":"Almila Sar\u0131g\u00fcl","family":"Sezen\u00f6z","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sirel G\u00fcr","family":"G\u00fcng\u00f6r","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u0130rem K\u0131rc\u0131","family":"Do\u011fan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meri\u00e7 Yavuz","family":"\u00c7olak","sequence":"additional","affiliation":[{"name":"Department of Biostatistics, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fcl\u015fah","family":"G\u00f6kg\u00f6z","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dilek Dursun","family":"Alt\u0131n\u00f6rs","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ba\u015fkent University, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"key":"R1-20260504","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1097\/IJG.0000000000001743","article-title":"Impact of trifocal and trifocal toric intraocular lenses on spectral-domain OCT retinal measurements","volume":"30","author":"Rementeria-Capelo","year":"2021","journal-title":"J Glaucoma"},{"key":"R2-20260504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","article-title":"Optical coherence tomography angiography","volume":"64","author":"Spaide","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"R3-20260504","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1146\/annurev-vision-100419-111350","article-title":"Optical coherence tomography and glaucoma","volume":"7","author":"Geevarghese","year":"2021","journal-title":"Annu Rev Vis Sci"},{"key":"R4-20260504","doi-asserted-by":"crossref","first-page":"3082","DOI":"10.1177\/11206721211062030","article-title":"Retinal nerve fiber layer and ganglion cell complex thickness as a diagnostic tool in early stage dysthyroid optic neuropathy","volume":"32","author":"Luo","year":"2022","journal-title":"Eur J Ophthalmol"},{"key":"R5-20260504","doi-asserted-by":"crossref","first-page":"32","DOI":"10.5301\/ejo.5001028","article-title":"Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens","volume":"28","author":"Garcia-Bella","year":"2018","journal-title":"Eur J Ophthalmol"},{"key":"R6-20260504","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/j.jcrs.2009.04.016","article-title":"Wavy horizontal artifacts on optical coherence tomography line-scanning images caused by diffractive multifocal intraocular lenses","volume":"35","author":"Inoue","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R7-20260504","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.2147\/OPTH.S411561","article-title":"Visual outcomes, spectacle independence, and patient-reported satisfaction of the vivity extended range of vision intraocular lens in patients with early glaucoma: An observational comparative study","volume":"17","author":"Kerr","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R8-20260504","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1097\/j.jcrs.0000000000001142","article-title":"Comparison of visual performance and quality of life with a new nondiffractive EDOF intraocular lens and a trifocal intraocular lens","volume":"49","author":"Asena","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260504","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1007\/s00417-021-05245-6","article-title":"Extended depth-of-focus (EDOF) AcrySof (R) IQ Vivity (R) intraocular lens implant: A real-life experience","volume":"259","author":"Arrigo","year":"2021","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R10-20260504","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1016\/j.jcrs.2019.06.014","article-title":"Visual quality and patient satisfaction with a trifocal intraocular lens and its new toric version","volume":"45","author":"Rementeria-Capelo","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260504","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.ajo.2017.09.016","article-title":"Visual performance of a quadrifocal (Trifocal) intraocular lens following removal of the crystalline lens","volume":"184","author":"Kohnen","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"R12-20260504","doi-asserted-by":"crossref","first-page":"4337","DOI":"10.4103\/ijo.IJO_754_22","article-title":"Retinal nerve fiber layer and ganglion cell complex thickness analysis in patients having relative afferent pupillary defect","volume":"70","author":"Mishra","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"R13-20260504","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.4103\/ijo.IJO_2409_20","article-title":"Comparison of diagnostic ability of standard automated perimetry, short wavelength automated perimetry, retinal nerve fiber layer thickness analysis and ganglion cell layer thickness analysis in early detection of glaucoma","volume":"69","author":"Kalyani","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R14-20260504","doi-asserted-by":"crossref","first-page":"2355","DOI":"10.1007\/s40520-022-02211-y","article-title":"Quantitative analysis of related parameters of retinal nerve fiber layer and ganglion cell complex thickness in patients with different degrees of Parkinson\u2019s disease","volume":"34","author":"Zhao","year":"2022","journal-title":"Aging Clin Exp Res"},{"key":"R15-20260504","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.mayocpiqo.2022.09.007","article-title":"Updates on the diagnosis and management of glaucoma","volume":"6","author":"Wagner","year":"2022","journal-title":"Mayo Clin Proc Innov Qual Outcomes"},{"key":"R16-20260504","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1159\/000458494","article-title":"Management of concomitant cataract and glaucoma","volume":"59","author":"Marchini","year":"2017","journal-title":"Dev Ophthalmol"},{"key":"R17-20260504","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1001\/archopht.119.7.985","article-title":"Discriminating between normal and glaucomatous eyes using the Heidelberg retina tomograph, GDx nerve fiber analyzer, and optical coherence tomograph","volume":"119","author":"Zangwill","year":"2001","journal-title":"Arch Ophthalmol"},{"key":"R18-20260504","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1136\/bjophthalmol-2017-310869","article-title":"Macular imaging by optical coherence tomography in the diagnosis and management of glaucoma","volume":"102","author":"Kim","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R19-20260504","doi-asserted-by":"crossref","first-page":"S57","DOI":"10.1016\/j.ophtha.2017.07.015","article-title":"Detecting structural progression in glaucoma with optical coherence tomography","volume":"124","author":"Tatham","year":"2017","journal-title":"Ophthalmology"},{"key":"R20-20260504","doi-asserted-by":"crossref","first-page":"8626495","DOI":"10.1155\/2020\/8626495","article-title":"Changes in ganglion cell complex and peripapillary retinal nerve fiber layer after femtosecond laser-assisted cataract surgery compared to manual phacoemulsification in patients receiving a trifocal intraocular lens","volume":"2020","author":"Sanchez-Sanchez","year":"2020","journal-title":"J Ophthalmol"},{"key":"R21-20260504","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/APO.0000000000000253","article-title":"AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: A clinical overview","volume":"8","author":"Sudhir","year":"2019","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R22-20260504","doi-asserted-by":"crossref","first-page":"2449","DOI":"10.2147\/OPTH.S400083","article-title":"The novel optical design and clinical classification of a wavefront-shaping presbyopia-correcting intraocular lens","volume":"17","author":"Kohnen","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R23-20260504","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.2147\/OPTH.S105992","article-title":"Effect of cataract surgery on subfoveal choroidal and ganglion cell complex thicknesses measured by enhanced depth imaging optical coherence tomography","volume":"10","author":"Celik","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R24-20260504","doi-asserted-by":"crossref","first-page":"919","DOI":"10.29271\/jcpsp.2018.12.919","article-title":"Retinal nerve fiber layer thickness changes after phacoemulsification with intraocular lens implantation","volume":"28","author":"Amjad","year":"2018","journal-title":"J Coll Physicians Surg Pak"},{"key":"R25-20260504","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1136\/bjophthalmol-2013-303752","article-title":"Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography","volume":"98","author":"Bambo","year":"2014","journal-title":"Br J Ophthalmol"},{"key":"R26-20260504","doi-asserted-by":"crossref","first-page":"91","DOI":"10.4103\/ojo.OJO_93_2016","article-title":"Effect of phacoemulsification on measurement of retinal nerve fiber layer and optic nerve head parameters using spectral-domain-optical coherence tomography","volume":"10","author":"Jha","year":"2017","journal-title":"Oman J Ophthalmol"},{"key":"R27-20260504","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/IJG.0b013e3182894a16","article-title":"Effect of cataract and its removal on ganglion cell complex thickness and peripapillary retinal nerve fiber layer thickness measurements by fourier-domain optical coherence tomography","volume":"22","author":"Nakatani","year":"2013","journal-title":"J Glaucoma"},{"key":"R28-20260504","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1038\/s41433-018-0141-0","article-title":"Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation","volume":"32","author":"Garcia-Bella","year":"2018","journal-title":"Eye (Lond)"},{"key":"R29-20260504","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1111\/j.1755-3768.2012.02514.x","article-title":"The relationship between the optical density of cataract and its influence on retinal nerve fibre layer thickness measured with spectral domain optical coherence tomography","volume":"91","author":"Kok","year":"2013","journal-title":"Acta Ophthalmol"},{"key":"R30-20260504","first-page":"116","article-title":"Influence of cataract on time domain and spectral domain optical coherence tomography retinal nerve fiber layer measurements","volume":"21","author":"Kim","year":"2012","journal-title":"J Glaucoma"},{"key":"R31-20260504","doi-asserted-by":"crossref","first-page":"937","DOI":"10.3109\/02713683.2011.597535","article-title":"Influence of blue light-filtering intraocular lenses on retinal nerve fiber layer measurements by spectral-domain optical coherence tomography","volume":"36","author":"Kim","year":"2011","journal-title":"Curr Eye Res"},{"key":"R32-20260504","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1097\/IJG.0b013e3181ccb93b","article-title":"Effect of cataract and its removal on signal strength and peripapillary retinal nerve fiber layer optical coherence tomography measurements","volume":"20","author":"Mwanza","year":"2011","journal-title":"J Glaucoma"},{"key":"R33-20260504","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s10792-014-0016-8","article-title":"The impact of multifocal intraocular lens in retinal imaging with optical coherence tomography","volume":"35","author":"Dias-Santos","year":"2015","journal-title":"Int Ophthalmol"},{"key":"R34-20260504","first-page":"800","article-title":"Association between ganglion cell complex thinning and vision-related quality of life in glaucoma","volume":"140","author":"Nishida","year":"2022","journal-title":"JAMA Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1938_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:42:59Z","timestamp":1786650179000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_1938_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,5]]},"references-count":34,"journal-issue":{"issue":"Suppl 3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_1938_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,5]]},"assertion":[{"value":"2023-07-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}