{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T09:27:50Z","timestamp":1791019670363,"version":"4.1.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Comparison of three ultrasound (US) frequencies for phacoemulsification of hard cataracts to determine a frequency that makes phacoemulsification more efficacious and safer.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A randomized controlled trial was undertaken at a medical college and hospital. In total, 207 patients with grade 5.6\u20136.9 (LOCS III) senile cataract were randomized into three groups. Group I underwent phacoemulsification with 28-kHz frequency, group II with 42-kHz frequency, and group III with 53-kHz frequency. The effective phacoemulsification time (EPT) and estimated fluid usage (EFU) were compared intraoperatively. The endothelial cell parameters were analyzed for 6 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The groups were matched for age (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.467), gender (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.497), nuclear grade (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.321), and anterior chamber depth (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.635). The EPT and EFU were significantly lower in group III, compared to group II and group I, with\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001 and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001, respectively. Postoperatively, the endothelial cell density (ECD) was significantly higher in group III at 1 month (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001), 3 months (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001), and 6 months (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). The percentages of ECD loss were also significantly lower in group III; the difference was statistically significant (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001) up to 6 months postoperatively\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Higher frequency ultrasound was associated with a lower EPT and EFU as well as better endothelial preservation than lower frequencies in hard cataracts.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2163_21","type":"journal-article","created":{"date-parts":[[2022,3,28]],"date-time":"2022-03-28T07:53:23Z","timestamp":1648454003000},"page":"1180-1185","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":14,"title":["Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies: A randomized controlled trial"],"prefix":"10.4103","volume":"70","author":[{"given":"Taru","family":"Dewan","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Praveen K","family":"Malik","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Preeti","family":"Tomar","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,3,22]]},"reference":[{"key":"B1-20240828","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.jcrs.2019.04.015","article-title":"Comparison of effective phacoemulsification time and corneal endothelial cell loss using 2 ultrasound frequencies","volume":"45","author":"Dewan","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"B2-20240828","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The lens opacities classification system III. The longitudinal study of cataract study group","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"B3-20240828","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s40662-017-0087-5","article-title":"Effect of IOP based infusion system with and with-out balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification","volume":"4","author":"Malik","year":"2017","journal-title":"Eye Vis"},{"key":"B4-20240828","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.jcrs.2016.02.039","article-title":"Nanosecond laser\u2013assisted cataract surgery: Endothelial cell study","volume":"42","author":"Tanev","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"B5-20240828","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.jcrs.2016.11.037","article-title":"Differences in energy expenditure for conventional and femtosecond-assisted cataract surgery using 2 different phacoemulsification systems","volume":"43","author":"Yesilirmak","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"B6-20240828","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1055\/s-2007-1011535","article-title":"Technische Aspekte der Ultraschall aspiration (Technical aspects of ultrasound aspiration)","volume":"11","author":"Krattiger","year":"1990","journal-title":"Ultraschall Med"},{"key":"B7-20240828","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/0301-5629(95)02021-7","article-title":"Physics of ultrasonic surgery using tissue fragmentation: Part I","volume":"22","author":"Cimino","year":"1996","journal-title":"Ultrasound Med Biol"},{"key":"B8-20240828","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/0301-5629(86)90337-6","article-title":"A new motor-driven surgical probe and its in vitro comparison with the Cavitron Ultrasonic Surgical Aspirator","volume":"12","author":"Chan","year":"1986","journal-title":"Ultrasound Med Biol"},{"key":"B9-20240828","doi-asserted-by":"crossref","first-page":"359","DOI":"10.3109\/02713689308999460","article-title":"Formation of free radicals during phacoemulsification","volume":"12","author":"Holst","year":"1993","journal-title":"Curr Eye Res"},{"key":"B10-20240828","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/S0886-3350(13)80587-1","article-title":"Ultrasonic energy in phacoemulsification: Mechanical cutting and cavitation","volume":"20","author":"Pacifico","year":"1994","journal-title":"J Cataract Refract Surg"},{"key":"B11-20240828","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.jcrs.2013.05.033","article-title":"Corneal endothelial cell loss and corneal thickness in conventional compared with femtosecond laser-assisted cataract surgery: Three-month follow-up","volume":"39","author":"Conrad-Hengerer","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"B12-20240828","doi-asserted-by":"crossref","first-page":"e0146676","DOI":"10.1371\/journal.pone.0146676","article-title":"Coaxial microincision cataract surgery versus standard coaxial small-incision cataract surgery: A meta-analysis of randomized controlled trials","volume":"11","author":"Shentu","year":"2016","journal-title":"PLoS One"},{"key":"B13-20240828","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/ICO.0b013e3181583115","article-title":"Corneal endothelial cell loss after cataract extraction by using ultrasound phacoemulsification versus a fluid-based system","volume":"27","author":"Richard","year":"2008","journal-title":"Cornea"},{"key":"B14-20240828","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/S0886-3350(03)00620-5","article-title":"Endothelial cell integrity after phacoemulsification with 2 different handpieces","volume":"30","author":"Vargas","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"B15-20240828","doi-asserted-by":"crossref","first-page":"204","DOI":"10.7869\/djo.172","article-title":"Let's talk in frequencies","volume":"26","author":"Dewan","year":"2016","journal-title":"Delhi J Ophthalmol"},{"key":"B16-20240828","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/S0886-3350(99)00462-9","article-title":"Endothelial cell loss after phacoemulsification: Relation to preoperative and intraoperative parameters","volume":"26","author":"Walkow","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"B17-20240828","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/0891-5849(92)90021-8","article-title":"Free radical formation induced by ultrasound and its biological implications","volume":"13","author":"Riesz","year":"1992","journal-title":"Free Radic Biol Med"},{"key":"B18-20240828","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/S0886-3350(00)00643-X","article-title":"Identification of free radicals produced during phacoemulsification","volume":"27","author":"Cameron","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"B19-20240828","first-page":"55","article-title":"Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision","volume":"7","author":"Assaf","year":"2013","journal-title":"Clin Ophthalmol"},{"key":"B20-20240828","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jcrs.2011.07.041","article-title":"Stroke dynamics and frequency of three phacoemulsification machines","volume":"38","author":"Tognetto","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"B21-20240828","first-page":"1313","article-title":"Aspiration method of hard nuclear cataract","volume":"74","author":"Kuwahara","year":"1970","journal-title":"Nippon Ganka Gakkai Zasshi"},{"key":"B22-20240828","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.jcrs.2011.08.035","article-title":"Intraoperative performance and postoperative outcome comparison of longitudinal, torsional, and transversal phacoemulsification machines","volume":"38","author":"Christakis","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"B23-20240828","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/S0886-3350(96)80121-0","article-title":"Risk factors for corneal endothelial injury during phacoemulsification","volume":"22","author":"Hayashi","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"B24-20240828","first-page":"2911","article-title":"Micromechanical characterization of lung tissue using Atomic Force Microscopy","volume":"28","author":"Liu","year":"2011","journal-title":"J Vis Exp"},{"key":"B25-20240828","article-title":"Vibrational spectroscopic imaging for biomedical applications. Tissue Imaging with Coherent Anti-Strokes Raman Scattering Microscopy, McGraw-Hill Professional","author":"Srinivasan","year":"2010"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2163_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:10:04Z","timestamp":1787166604000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2163_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,22]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2163_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,22]]},"assertion":[{"value":"2021-09-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}