{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:31:05Z","timestamp":1787070665352,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To report visual outcomes of enhancement after corneal lenticular extraction for advanced refractive correction (CLEAR, Femto LDV) using the CIRCLE software (Carl Zeiss Meditec, Germany).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A prospective interventional study included eyes undergoing enhancement for under-correction or regression following CLEAR; at least three months after the primary procedure. CIRCLE software (pattern D) was used to convert the initial cap into a flap, which was subsequently raised and the stromal bed was ablated using an excimer laser (Zeiss Mel 90), with a Plano target in all eyes. Safety and visual outcomes at the three months postoperative visit were analyzed, with maximum follow-up till one year.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Nine eyes of six patients were included in the data analysis. The mean preoperative refractive spherical equivalent treated using the CLEAR software was \u22125.04 \u00b1 2.28 diopter (D). Enhancement was performed for a mean residual error of \u22120.86 \u00b1 0.54 D. The CIRCLE procedure was performed 6.67 \u00b1 1.79 months after the primary procedure and resulted in a final manifest spherical equivalent of \u2212 0.01 \u00b1 0.04 D at the three months postoperative visit (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001867). Mean uncorrected distance visual acuity (UDVA) improved from logMAR 0.31 \u00b1 0.11 to 0.01 \u00b1 0.03 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.0008). Post-enhancement UDVA of 20\/20 or better was achieved in 78% of the eyes. None of the eyes reported loss of lines in corrected distance visual acuity (CDVA). No intraoperative complications were noted in the cohort. No incidence of epithelial ingrowth, regression, or stromal haze was noted up till one year postoperative visit.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>CIRCLE software may be considered as an optional treatment modality for enhancement following CLEAR.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2186_24","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T07:00:09Z","timestamp":1744873209000},"page":"1012-1015","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Enhancement using CIRCLE software post cornea lenticule extraction for advanced refractive correction"],"prefix":"10.4103","volume":"73","author":[{"given":"Gitansha S","family":"Sachdev","sequence":"first","affiliation":[{"name":"Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tasneem","family":"Neemuchwala","sequence":"additional","affiliation":[{"name":"Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shreyas","family":"Ramamurthy","sequence":"additional","affiliation":[{"name":"Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"key":"R1-20260421","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1136\/bjophthalmol-2018-312140","article-title":"Three-year outcomes of small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for myopia and myopic astigmatism","volume":"103","author":"Han","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"R2-20260421","doi-asserted-by":"crossref","first-page":"256","DOI":"10.3928\/1081597X-20151111-06","article-title":"Clinical outcomes of SMILE and FS-LASIK used to treat myopia: A meta-analysis","volume":"32","author":"Zhang","year":"2016","journal-title":"J Refract Surg"},{"key":"R3-20260421","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1097\/ICO.0000000000003123","article-title":"Refractive corneal lenticule extraction with the CLEAR femtosecond laser application","volume":"42","author":"Leccisotti","year":"2023","journal-title":"Cornea"},{"key":"R4-20260421","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1097\/j.jcrs.0000000000000236","article-title":"Corneal lenticule extraction assisted by a low-energy femtosecond laser","volume":"46","author":"Izquierdo","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R5-20260421","doi-asserted-by":"crossref","first-page":"94","DOI":"10.3928\/1081597X-20140120-04","article-title":"Comparison of corneal sensation between small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK for myopia","volume":"30","author":"Li","year":"2014","journal-title":"J Refract Surg"},{"key":"R6-20260421","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.jcrs.2013.08.065","article-title":"Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: Finite-element analysis","volume":"40","author":"Sinha Roy","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R7-20260421","doi-asserted-by":"crossref","first-page":"236","DOI":"10.3928\/1081597X-20130318-02","article-title":"Comparison of four different VisuMax circle patterns for flap creation after small incision lenticule extraction","volume":"29","author":"Riau","year":"2013","journal-title":"J Refract Surg"},{"key":"R8-20260421","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3928\/1081597X-20180308-02","article-title":"CIRCLE enhancement after myopic SMILE","volume":"34","author":"Siedlecki","year":"2018","journal-title":"J Refract Surg"},{"key":"R9-20260421","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.ophtha.2017.01.053","article-title":"Enhancement after small incision lenticule extraction: Incidence, risk factors and outcomes","volume":"124","author":"Liu","year":"2017","journal-title":"Ophthalmology"},{"key":"R10-20260421","doi-asserted-by":"crossref","first-page":"812","DOI":"10.3928\/1081597X-20141113-07","article-title":"Outcomes of small incision lenticule extraction in low myopia","volume":"30","author":"Reinstein","year":"2014","journal-title":"J Refract Surg"},{"key":"R11-20260421","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/APO.0000000000000259","article-title":"Enhancement options after myopic small-incision lenticule extraction (SMILE): A review","volume":"8","author":"Siedlecki","year":"2019","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R12-20260421","doi-asserted-by":"crossref","first-page":"294","DOI":"10.3928\/1081597X-20190416-02","article-title":"Surface ablation versus CIRCLE for myopic enhancement after SMILE: A matched comparative study","volume":"35","author":"Siedlecki","year":"2019","journal-title":"J Refract Surg"},{"key":"R13-20260421","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1167\/iovs.15-18879","article-title":"Corneal epithelial remod- eling induced by small incision lenticule extraction (SMILE)","volume":"57","author":"Luft","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20260421","doi-asserted-by":"crossref","first-page":"473","DOI":"10.3928\/1081597X-20160512-01","article-title":"Epithelial thickness profile changes following small incision refractive lenticule extraction (SMILE) for myopia and myopic astigmatism","volume":"32","author":"Ganesh","year":"2016","journal-title":"J Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2186_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:34:27Z","timestamp":1787067267000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2186_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":14,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2186_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"assertion":[{"value":"2024-09-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}