{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:35:10Z","timestamp":1786649710577,"version":"build-2736575974"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the agreement between the biometric measurements used to calculate the size of the implantable collamer lenses (ICL) with different technologies: swept-source optical coherence tomography, spectral domain optical coherence tomography, and Scheimpflug tomography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This retrospective observational study included subjects undergoing refractive surgery with posterior chamber phakic IOL implantation to correct their myopia. The anterior chamber depth (ACD) and the horizontal white to white (WTW) or the angle to angle (ATA) distance were measured with the following four devices: the IOLMaster 700 biometer (Carl Zeiss Meditec, Jena, Germany), based on swept-source optical coherence tomography; the Cirrus and Visante optical coherence tomographs (Carl Zeiss Meditec) based on low-coherence interferometry; and the Pentacam rotating Scheimpflug camera (Oculus, Wetzlar, Germany).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      In the horizontal corneal diameter measurements, there were statistically significant differences between Pentacam\u2013IOLMaster 700 pair (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) and Pentacam\u2013Visante pair (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). WTW from CIRRUS showed the lowest correlation when paired with Pentacam and IOLMaster 700 (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.452 and 0.385 for Visante and\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.494 and 0.426 for Cirrus). Regarding the linear correlation of the ACD measurements, all pairs of devices were statistically significant and all of them showed a very good correlation index.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>There is a good agreement between the different devices under evaluation for ACD measurements. As for WTW, the values measured with the different devices showed large discrepancies with low correlation levels, especially when comparing the tomographs with the other devices under evaluation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2217_21","type":"journal-article","created":{"date-parts":[[2022,5,11]],"date-time":"2022-05-11T06:53:23Z","timestamp":1652252003000},"page":"1586-1592","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Agreement between the biometric measurements used to calculate the size of the implantable collamer lenses measured with four different technologies"],"prefix":"10.4103","volume":"70","author":[{"given":"Jorge A","family":"Calvo-Sanz","sequence":"first","affiliation":[{"name":"INCIVI, Ana Teresa, 24, Optometry and Opthalmology Department, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Poyales","sequence":"additional","affiliation":[{"name":"Miranza IOA, Madrid, Optometry and Opthalmology, Complutense University, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Zhou","sequence":"additional","affiliation":[{"name":"Miranza IOA, Madrid, Optometry and Opthalmology, Complutense University, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfonso","family":"Arias-Puente","sequence":"additional","affiliation":[{"name":"INCIVI, Ana Teresa, 24, Optometry and Opthalmology Department, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nuria","family":"Garz\u00f3n","sequence":"additional","affiliation":[{"name":"Miranza IOA, Madrid, Optometry and Opthalmology, Complutense University, Madrid, Spain"},{"name":"Department of Faculty of Optics and Optometry, Complutense University, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,4,28]]},"reference":[{"key":"R1-20251006","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.jcrs.2010.08.014","article-title":"Phakic intraocular lenses part 1: Historical overview, current models, selection criteria, and surgical techniques","volume":"36","author":"Guell","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R2-20251006","doi-asserted-by":"crossref","first-page":"293","DOI":"10.4103\/0974-9233.194076","article-title":"Causes of phakic implantable collamer lens explantation\/exchange at King Khaled Eye Specialist Hospital","volume":"23","author":"AlSabaani","year":"2016","journal-title":"Middle East Afr J Ophthalmol"},{"key":"R3-20251006","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.jcjo.2017.11.018","article-title":"Incidence of implantable Collamer lens-induced cataract","volume":"53","author":"Gimbel","year":"2018","journal-title":"Can J Ophthalmol"},{"key":"R4-20251006","first-page":"137","article-title":"Acute angle-closure glaucoma secondary to a phakic intraocular lens, an ophthalmic emergency","volume":"3","author":"Frost","year":"2019","journal-title":"Clin Pract Cases Emerg Med"},{"key":"R5-20251006","first-page":"461","article-title":"Importancia de la Tomograf\u00eda de Coherencia \u00d3ptica (OCT-Visante) en el Implante y Seguimiento de las Lentes Intraoculares F\u00e1quicas42. P\u00e1ginas","author":"Alfonso","year":"2011","journal-title":"Monograf\u00eda SECOIR"},{"key":"R6-20251006","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.jcrs.2011.01.024","article-title":"Repeatability of the ciliary sulcus-to-sulcus diameter measurement using wide-scanning-field ultrasound biomicroscopy","volume":"37","author":"Yokoyama","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R7-20251006","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1016\/j.ophtha.2006.12.018","article-title":"Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy","volume":"114","author":"Oh","year":"2007","journal-title":"Ophthalmology"},{"key":"R8-20251006","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.2147\/OPTH.S111620","article-title":"Meta-analysis and review: Effectiveness, safety, and central port design of the intraocular collamer lens","volume":"10","author":"Packer","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R9-20251006","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.jfo.2011.06.006","article-title":"[Long-term results of posterior chamber phakic intraocular lens implantation for correction of high ametropia]","volume":"35","author":"Le Loir","year":"2012","journal-title":"J Fr Ophtalmol"},{"key":"R10-20251006","doi-asserted-by":"crossref","first-page":"202","DOI":"10.5301\/ejo.5000524","article-title":"Interchangeability between pentacam and IOLMaster in phakic intraocular lens calculation","volume":"25","author":"Sayed","year":"2015","journal-title":"Eur J Ophthalmol"},{"key":"R11-20251006","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","article-title":"Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography","volume":"187","author":"Nakamura","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R12-20251006","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/S0886-3350(00)00759-8","article-title":"Implantable contact lens for moderate to high myopia: Short-term follow-up of 2 models","volume":"27","author":"Gonvers","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R13-20251006","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.ophtha.2009.12.013","article-title":"Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients","volume":"117","author":"Schmidinger","year":"2010","journal-title":"Ophthalmology"},{"key":"R14-20251006","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.jcrs.2010.11.037","article-title":"Risk factor evaluation for cataract development in patients with low vaulting after phakic intraocular lens implantation","volume":"37","author":"Maeng","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R15-20251006","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/S0886-3350(03)00065-8","article-title":"Implantable contact lens for moderate to high myopia: Relationship of vaulting to cataract formation","volume":"29","author":"Gonvers","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R16-20251006","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2014.06.036","article-title":"Prevention and management of collagen copolymer phakic intraocular lens exchange: Causes and surgical techniques","volume":"41","author":"Zeng","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R17-20251006","doi-asserted-by":"crossref","first-page":"2427","DOI":"10.2147\/OPTH.S188785","article-title":"The implantable collamer lens with a central port: Review of the literature","volume":"12","author":"Packer","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R18-20251006","doi-asserted-by":"crossref","first-page":"1982","DOI":"10.1016\/j.jcrs.2003.10.041","article-title":"Correlation between different measurements within the eye relative to phakic intraocular lens implantation","volume":"30","author":"Werner","year":"2004","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2217_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:57:29Z","timestamp":1786647449000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2217_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,28]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2217_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,28]]},"assertion":[{"value":"2021-08-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}