{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:37:03Z","timestamp":1786649823205,"version":"build-2736575974"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:p>We demonstrate a modified internal limiting membrane (ILM) inverted flap technique for closure of macular holes (MHs) concurrent with rhegmatogenous retinal detachment in myopic eyes. Multiple ILM flaps were created in a flower-petal configuration around the MH over the detached retina after shallowing the retina as much as possible. Traction was always in a direction that allowed the optic disc to act as an anchor to limit iatrogenic breaks and to bridge the hole with multiple, more secure flaps should one of the flaps revert or break away. The technique proved safe and efficient in MH closure in our series of eight cases. The modification described provides an effective approach for challenging myopic cases in which ILM flap creation is needed over a detached retina.<\/jats:p>","DOI":"10.4103\/ijo.ijo_2226_21","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T07:51:02Z","timestamp":1644997862000},"page":"667-669","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Flower-petal inverted flap for internal limiting membrane in myopic eyes with macular hole and rhegmatogenous retinal detachment"],"prefix":"10.4103","volume":"70","author":[{"given":"Ahmed M","family":"Habib","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Ain Shams University, Cairo, Egypt"},{"name":"Vitreoretinal Service, Al Mashreq Eye Hospital, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Mansour","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ain Shams University, Cairo, Egypt"},{"name":"Vitreoretinal Service, Al Mashreq Eye Hospital, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yousef A","family":"Fouad","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ain Shams University, Cairo, Egypt"},{"name":"Vitreoretinal Service, Al Mashreq Eye Hospital, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,27]]},"reference":[{"key":"R1-20251006","doi-asserted-by":"crossref","first-page":"e0165068","DOI":"10.1371\/journal.pone.0165068","article-title":"Comparison of the inverted internal limiting membrane flap technique and the internal limiting membrane peeling for macular hole with retinal detachment","volume":"11","author":"Matsumura","year":"2016","journal-title":"PLoS One"},{"key":"R2-20251006","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska","year":"2010","journal-title":"Ophthalmology"},{"key":"R3-20251006","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1097\/IAE.0000000000000042","article-title":"Inverted internal limiting membrane flap technique for surgical repair of myopic macular holes","volume":"34","author":"Michalewska","year":"2014","journal-title":"Retina"},{"issue":"Suppl 1","key":"R4-20251006","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1097\/IAE.0000000000001985","article-title":"Internal limiting membrane peeling versus inverted flap technique for treatment of full-thickness macular holes:A comparative study in a large series of patients","volume":"38","author":"Rizzo","year":"2018","journal-title":"Retina"},{"key":"R5-20251006","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1186\/s12886-018-0826-y","article-title":"Comparative study of inverted Internal limiting membrane (ILM) flap and ILM peeling technique in large macular holes:A randomized-control trial","volume":"18","author":"Kannan","year":"2018","journal-title":"BMC Ophthalmol"},{"key":"R6-20251006","doi-asserted-by":"crossref","first-page":"830","DOI":"10.3928\/23258160-20170928-08","article-title":"Cabbage leaf Inverted flap ILM peeling for macular hole:A novel technique","volume":"48","author":"Aurora","year":"2017","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R7-20251006","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1038\/eye.2016.263","article-title":"Inverted internal limiting membrane flap technique as a useful procedure for macular hole-associated retinal detachment in highly myopic eyes","volume":"31","author":"Sasaki","year":"2017","journal-title":"Eye"},{"key":"R8-20251006","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1038\/s41433-019-0458-3","article-title":"Vitrectomy with inverted internal limiting membrane flap versus internal limiting membrane peeling for macular hole retinal detachment in high myopia:A systematic review of literature and meta-analysis","volume":"33","author":"Xu","year":"2019","journal-title":"Eye"},{"key":"R9-20251006","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1097\/IAE.0b013e3181a3b8fc","article-title":"Combined or sequential surgery for management of rhegmatogenous retinal detachment with macular holes","volume":"29","author":"Singh","year":"2009","journal-title":"Retina"},{"key":"R10-20251006","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1016\/j.ophtha.2019.01.027","article-title":"Autologous retinal transplant for refractory macular holes:Multicenter international collaborative study group","volume":"126","author":"Grewal","year":"2019","journal-title":"Ophthalmology"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2226_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:58:49Z","timestamp":1786647529000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_2226_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,27]]},"references-count":10,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2226_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,27]]},"assertion":[{"value":"2021-08-27","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-09-21","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}