{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:30:33Z","timestamp":1792132233333,"version":"4.4.0"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:00Z","timestamp":1740528000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A retrospective, cross-sectional study was conducted in Istanbul Ba\u015fak\u015fehir \u00c7am and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08\u20132.11) D in group 1 and 0.99 (0.31\u20132.96) D in group 2 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic\u2013haptic separation were observed perioperatively. Optic\u2013haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.019).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2235_24","type":"journal-article","created":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T03:05:07Z","timestamp":1740539107000},"page":"416-421","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of two different intraocular lenses used in the modified Yamane technique"],"prefix":"10.4103","volume":"73","author":[{"given":"Fahri O","family":"Aydin","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burakhan K","family":"Aksoy","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Ceylan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuf B","family":"Akba\u015f","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Murat","family":"Karapapak","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bur\u00e7in Kepez","family":"Yildiz","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuf","family":"Yildirim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"R1-20260422","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1080\/09286586.2016.1270335","article-title":"The prevalence of age-related eye disease in an elderly population","volume":"24","author":"Hashemi","year":"2017","journal-title":"Ophthalmic Epidemiol"},{"key":"R3-20260422","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.jcrs.2018.06.049","article-title":"Iris-claw intraocular lens implantation: Efficiency and safety according to technique","volume":"44","author":"Mart\u00ednez","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R4-20260422","doi-asserted-by":"crossref","first-page":"e129","DOI":"10.3928\/23258160-20181002-15","article-title":"Comparison of two modified sutureless techniques of scleral fixation of intraocular lens","volume":"49","author":"Kelkar","year":"2018","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0886-3350(96)80227-6","article-title":"Secondary implantation of angle-supported anterior chamber and scleral-fixated posterior chamber intraocular lenses","volume":"22","author":"Bellucci","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R6-20260422","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R7-20260422","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/ICU.0000000000000632","article-title":"Scleral fixation of intraocular lenses","volume":"31","author":"Jacob","year":"2020","journal-title":"Curr Opin Ophthalmol"},{"key":"R8-20260422","first-page":"389","article-title":"Sutureless transconjunctival intrascleral intraocular lens fixation: The modified Yamane technique","volume":"82","author":"Yavuzer","year":"2019","journal-title":"Arq Bra Oftalmol"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1007\/s10792-021-02107-2","article-title":"Evaluation of anterior segment structures with Scheimpflug camera in patients undergoing sutureless scleral fixation by modified Yamane technique","volume":"42","author":"Yavuzer","year":"2022","journal-title":"Int Ophthalmol"},{"key":"R10-20260422","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.jcrs.2003.08.023","article-title":"Anterior chamber depth, iridocorneal angle width, and intraocular pressure changes after uneventful phacoemulsification in eyes without glaucoma and with open iridocorneal angles","volume":"30","author":"Altan","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260422","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1016\/j.ophtha.2020.03.032","article-title":"Refractive outcomes of the Yamane flanged intrascleral haptic fixation technique","volume":"127","author":"Rocke","year":"2020","journal-title":"Ophthalmology"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00417-014-2834-9","article-title":"Sutureless scleral fixation of intraocular lenses: Outcomes of two approaches. The 2014 Yasuo Tano memorial lecture","volume":"253","author":"Abbey","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.ajo.2021.02.021","article-title":"A biomechanical study of flanged intrascleral haptic fixation of three-piece intraocular lenses","volume":"227","author":"Ma","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R14-20260422","doi-asserted-by":"crossref","first-page":"243170","DOI":"10.1155\/2011\/243170","article-title":"Minimizing surgically induced astigmatism at the time of cataract surgery using a square posterior limbal incision","volume":"2011","author":"Ernest","year":"2011","journal-title":"J Ophthalmol"},{"key":"R15-20260422","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1097\/j.jcrs.0000000000000540","article-title":"Accuracy of intraocular lens calculation formulas for flanged intrascleral intraocular lens fixation with double-needle technique","volume":"47","author":"McMillin","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R16-20260422","doi-asserted-by":"crossref","first-page":"8534028","DOI":"10.1155\/2020\/8534028","article-title":"Comparison of different IOL types in the flanged IOL fixation technique","volume":"2020","author":"Miura","year":"2020","journal-title":"J Ophthalmol"},{"key":"R17-20260422","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/S0886-3350(02)01522-5","article-title":"Computerized analysis of the effects of intraocular lens edge design on the quality of vision in pseudophakic patients","volume":"29","author":"Franchini","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R18-20260422","doi-asserted-by":"crossref","first-page":"1792","DOI":"10.1016\/S0886-3350(00)00748-3","article-title":"Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes: Part 1: Histological sections","volume":"26","author":"Linnola","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R19-20260422","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1016\/S0886-3350(00)00747-1","article-title":"Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes: Part 2: Explanted intraocular lenses","volume":"26","author":"Linnola","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R20-20260422","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1016\/S0886-3350(99)00238-2","article-title":"Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials","volume":"25","author":"Linnola","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R21-20260422","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1038\/sj.eye.6702496","article-title":"Comparison of posterior capsule opacification between fellow eyes with two types of acrylic intraocular lens","volume":"22","author":"Hayashi","year":"2008","journal-title":"Eye"},{"key":"R22-20260422","doi-asserted-by":"crossref","first-page":"e00083","DOI":"10.1097\/j.jcro.0000000000000083","article-title":"Intrascleral haptic needle fixation of 20+-year-old dislocated intraocular lenses using trailing-haptic-first modification","volume":"10","author":"Kim","year":"2022","journal-title":"JCRS Online Case Rep"},{"key":"R23-20260422","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1016\/S0886-3350(02)01326-3","article-title":"Loop memory of haptic materials in posterior chamber intraocular lenses","volume":"28","author":"Izak","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R24-20260422","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1159\/000504563","article-title":"Double-needle yamane repositioning of a previous Yamane fixation","volume":"10","author":"Pugazhendhi","year":"2019","journal-title":"Case Rep Ophthalmol"},{"key":"R25-20260422","doi-asserted-by":"crossref","first-page":"2317","DOI":"10.4103\/ijo.IJO_1636_20","article-title":"Surgical outcomes and complications of sutureless needle-guided intrascleral intraocular lens fixation combined with vitrectomy","volume":"69","author":"Shelke","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R26-20260422","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1136\/bjo.2006.099945","article-title":"Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration","volume":"91","author":"Oshika","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"R27-20260422","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1007\/s10792-021-02106-3","article-title":"Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation","volume":"42","author":"Tokuhisa","year":"2022","journal-title":"Int Ophthalmol"},{"key":"R28-20260422","doi-asserted-by":"crossref","first-page":"e928868","DOI":"10.12659\/MSM.928868","article-title":"Long-term stability of intraocular lens with trimmed or untrimmed haptics in Yamane sutureless intrascleral fixation technique","volume":"27","author":"Lin","year":"2021","journal-title":"Med Sci Monit"},{"key":"R29-20260422","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s40662-023-00341-6","article-title":"Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: A comparison of three-piece and one-piece intrascleral fixation technique","volume":"10","author":"Schranz","year":"2023","journal-title":"Eye Vis"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2235_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:27:50Z","timestamp":1787837270000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2235_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,26]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2235_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,26]]},"assertion":[{"value":"2024-09-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}