{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:32:37Z","timestamp":1786649557651,"version":"build-2736575974"},"reference-count":81,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 3","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:p>To assess the role of various types of contact lenses (CL) after penetrating and lamellar keratoplasty, we reviewed all studies that were related to CL fitting in post-keratoplasty (full-thickness and lamellar) eyes between 1990 and 2024 by using relevant search keywords. The demographic data, indications for CL fitting, duration between keratoplasty and CL fitting, CL design and fitting methodologies, refractive outcomes, topographic and biomechanical changes, aberrometry, specular microscopy, corneal thickness, graft survival, and complications were analyzed. A total of 32 original studies and seven case reports were evaluated. All studies showed favorable refractive outcomes. Complications, if any, were managed successfully with conservative treatment and temporary discontinuation of lens wear. Most authors preferred to use large-diameter multicurve rigid-gas permeable lenses and scleral lenses over hydrogels and hybrid or piggy-back varieties, with an inclination toward late fitting due to multiple factors. The lenses did not have any adverse effect on graft survival. CLs are a useful tool in post-keratoplasty visual rehabilitation. However, patients require meticulous workup, a thorough fitting methodology, attention to associated problems, and close follow-up to monitor for complications.<\/jats:p>","DOI":"10.4103\/ijo.ijo_2394_24","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T07:00:12Z","timestamp":1744873212000},"page":"S369-S383","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Contact lenses for visual rehabilitation in post-keratoplasty eyes: A review"],"prefix":"10.4103","volume":"73","author":[{"given":"Mohamed Ibrahime","family":"Asif","sequence":"first","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nidhi","family":"Kalra","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manasi","family":"Tripathi","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mrinalini Anand","family":"Yadav","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahnaz","family":"Anjum","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajesh","family":"Sinha","sequence":"additional","affiliation":[{"name":"Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"key":"R1-20260422","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/S0886-3350(00)00430-2","article-title":"Penetrating keratoplasty for keratoconus: A long-term review of results and complications","volume":"26","author":"Olson","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R2-20260422","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1097\/01.ico.0000159730.45177.cd","article-title":"Outcomes of penetrating keratoplasty in keratoconus","volume":"24","author":"Javadi","year":"2005","journal-title":"Cornea"},{"key":"R3-20260422","doi-asserted-by":"crossref","first-page":"3306.","DOI":"10.3390\/jcm13113306","article-title":"Postoperative astigmatism after keratoplasty: A systematic review meta-analysis based on PRISMA","volume":"13","author":"Kijonka","year":"2024","journal-title":"J Clin Med"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.survophthal.2021.11.005","article-title":"Post-penetrating keratoplasty astigmatism","volume":"67","author":"Deshmukh","year":"2022","journal-title":"Surv Ophthalmol"},{"key":"R6-20260422","first-page":"47","article-title":"The Australian corneal graft registry 1996 report","volume":"11","author":"Williams","year":"1997","journal-title":"Adel Mercury Press"},{"key":"R7-20260422","doi-asserted-by":"crossref","first-page":"832070.","DOI":"10.1155\/2012\/832070","article-title":"Contact lens visual rehabilitation in keratoconus and corneal keratoplasty","volume":"2012","author":"Ozkurt","year":"2012","journal-title":"J Ophthalmol"},{"issue":"Suppl 3","key":"R8-20260422","first-page":"130","article-title":"Visual rehabilitation after penetrating keratoplasty","volume":"14","author":"Asena","year":"2016","journal-title":"Exp Clin Transplant Off J Middle East Soc Organ Transplant"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/0039-6257(90)90123-D","article-title":"Refracting the corneal graft","volume":"34","author":"Mannis","year":"1990","journal-title":"Surv Ophthalmol"},{"key":"R10-20260422","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/j.1444-0938.2003.tb03113.x","article-title":"Contact lens fitting following corneal graft surgery","volume":"86","author":"Szczotka","year":"2003","journal-title":"Clin Exp Optom"},{"key":"R11-20260422","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1016\/j.jcrs.2012.09.002","article-title":"Management of post-keratoplasty astigmatism","volume":"38","author":"Fares","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1097\/OPX.0000000000000018","article-title":"Medical applications and outcomes of bitangential scleral lenses","volume":"90","author":"Visser","year":"2013","journal-title":"Optom Vis Sci Off Publ Am Acad Optom"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.clae.2014.10.001","article-title":"Mini-scleral lenses in the visual rehabilitation of patients after penetrating keratoplasty and deep lamellar anterior keratoplasty","volume":"38","author":"Alipour","year":"2015","journal-title":"Contact Lens Anterior Eye"},{"key":"R14-20260422","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1111\/opo.12693","article-title":"Scleral lens wear following penetrating keratoplasty: Changes in corneal curvature and optics","volume":"40","author":"Kumar","year":"2020","journal-title":"Ophthalmic Physiol Opt"},{"key":"R15-20260422","doi-asserted-by":"crossref","first-page":"100762.","DOI":"10.1016\/j.preteyeres.2019.05.003","article-title":"Corneal nerves in health and disease","volume":"73","author":"Al-Aqaba","year":"2019","journal-title":"Prog Retin Eye Res"},{"key":"R16-20260422","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.clae.2011.06.008","article-title":"Prevalence of contact lens related complications in a tertiary eye centre in India","volume":"34","author":"Nagachandrika","year":"2011","journal-title":"Contact Lens Anterior Eye"},{"key":"R17-20260422","first-page":"1768","article-title":"Endothelial parameters in central and peripheral cornea in patients wearing contact lenses","volume":"11","author":"Galgauskas","year":"2018","journal-title":"Int J Ophthalmol"},{"key":"R18-20260422","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.exer.2013.07.013","article-title":"Contact lens interactions with the tear film","volume":"117","author":"Mann","year":"2013","journal-title":"Exp Eye Res"},{"key":"R19-20260422","article-title":"Contact lenses in abnormal ocular conditions-Keratoconus","author":"Woodward"},{"issue":"Suppl","key":"R20-20260422","first-page":"83","article-title":"Application of the OK-3 lens design to corneal transplant patients","volume":"70","author":"Lin","year":"1993","journal-title":"Optom Vis Sci"},{"key":"R21-20260422","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/j.1444-0938.1995.tb00829.x","article-title":"Post-keratoplasty contact lens management","volume":"78","author":"Lindsay","year":"1995","journal-title":"Clin Exp Optom"},{"key":"R22-20260422","first-page":"179","article-title":"Therapeutic use of Bausch and Lomb PureVision contact lenses","volume":"27","author":"Lim","year":"2001","journal-title":"CLAO J Off Publ Contact Lens Assoc Ophthalmol Inc"},{"key":"R23-20260422","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.clae.2008.07.002","article-title":"Fitting the post-keratoplasty cornea with hydrogel lenses","volume":"32","author":"Katsoulos","year":"2009","journal-title":"Cont Lens Anterior Eye"},{"key":"R24-20260422","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/01.ICL.0000101488.84455.E6","article-title":"Fitting contact lenses for visual rehabilitation after penetrating keratoplasty","volume":"30","author":"Wietharn","year":"2004","journal-title":"Eye Contact Lens"},{"key":"R25-20260422","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.jcrs.2013.02.051","article-title":"Incidence of irregular astigmatism eligible for contact lens fitting after Descemet membrane endothelial keratoplasty","volume":"39","author":"van Dijk","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R26-20260422","first-page":"170","article-title":"Fitting the SoftPerm contact lens after keratoplasty","volume":"18","author":"Binder","year":"1992","journal-title":"CLAO J"},{"key":"R27-20260422","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1097\/ICL.0b013e31815c859b","article-title":"A comparison of synergeyes versus traditional rigid gas permeable lens designs for patients with irregular corneas","volume":"34","author":"Nau","year":"2008","journal-title":"Eye Contact Lens"},{"key":"R28-20260422","first-page":"173","article-title":"The use of the SoftPerm lens for the correction of irregular astigmatism","volume":"18","author":"Maguen","year":"1992","journal-title":"CLAO J"},{"key":"R29-20260422","first-page":"202","article-title":"Use of SoftPerm contact lenses when rigid gas permeable lenses fail","volume":"27","author":"Chung","year":"2001","journal-title":"CLAO J"},{"key":"R30-20260422","doi-asserted-by":"crossref","first-page":"451","DOI":"10.4103\/njcp.njcp_103_17","article-title":"Hybrid contact lenses for visual management of patients after keratoplasty","volume":"21","author":"Altay","year":"2018","journal-title":"Niger J Clin Pract"},{"key":"R31-20260422","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1111\/j.1444-0938.2006.00005.x","article-title":"A clinical and optical evaluation of a modified lens for irregular corneae","volume":"89","author":"Mehta","year":"2006","journal-title":"Clin Exp Optom"},{"key":"R32-20260422","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/00003226-199711000-00003","article-title":"A study of 530 patients referred for rigid gas permeable scleral contact lens assessment","volume":"16","author":"Pullum","year":"1997","journal-title":"Cornea"},{"key":"R33-20260422","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.clae.2014.02.002","article-title":"Modern scleral contact lenses: A review","volume":"37","author":"van der Worp","year":"2014","journal-title":"Contact Lens Anterior Eye"},{"key":"R34-20260422","first-page":"41","article-title":"Corneal topography for rigid gas permeable lens fitting after penetrating keratoplasty","volume":"19","author":"Lopatynsky","year":"1993","journal-title":"CLAO J"},{"key":"R35-20260422","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1136\/bjo.70.1.55","article-title":"Photokeratoscopy in fitting contact lens after penetrating keratoplasty","volume":"70","author":"Manabe","year":"1986","journal-title":"Br J Ophthalmol"},{"key":"R36-20260422","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0002-9394(14)77947-4","article-title":"Fitting gas-permeable contact lenses after penetrating keratoplasty","volume":"99","author":"Genvert","year":"1985","journal-title":"Am J Ophthalmol"},{"key":"R37-20260422","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1034\/j.1600-0420.2001.790307.x","article-title":"A new technique for rigid gas permeable contact lens fitting following penetrating keratoplasty","volume":"79","author":"Eggink","year":"2001","journal-title":"Acta Ophthalmol Scand"},{"key":"R38-20260422","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.clae.2020.04.009","article-title":"Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery","volume":"43","author":"Montalt","year":"2020","journal-title":"Contact Lens Anterior Eye"},{"key":"R39-20260422","doi-asserted-by":"crossref","first-page":"475","DOI":"10.5935\/0004-2749.20180089","article-title":"Visual performance of scleral lenses and their impact on quality of life in patients with irregular corneas","volume":"81","author":"Ozek","year":"2018","journal-title":"Arq Bras Oftalmol"},{"key":"R40-20260422","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.clae.2020.10.008","article-title":"Acute corneal edema decades after penetrating keratoplasty for keratoconus in eyes wearing scleral contact lenses","volume":"44","author":"Murillo","year":"2021","journal-title":"Contact Lens Anterior Eye"},{"key":"R41-20260422","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/ICL.0000000000000163","article-title":"Use of scleral lenses and miniscleral lenses after penetrating keratoplasty","volume":"42","author":"Barnett","year":"2016","journal-title":"Eye Contact Lens"},{"key":"R42-20260422","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.clae.2013.11.001","article-title":"Scleral contact lenses for visual rehabilitation after penetrating keratoplasty: Long term outcomes","volume":"37","author":"Severinsky","year":"2014","journal-title":"Contact Lens Anterior Eye"},{"key":"R43-20260422","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1097\/ICO.0b013e3182a73802","article-title":"Functional and visual improvement with prosthetic replacement of the ocular surface ecosystem scleral lenses for irregular corneas","volume":"32","author":"Lee","year":"2013","journal-title":"Cornea"},{"key":"R44-20260422","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.ajo.2010.10.027","article-title":"The impact of the Boston ocular surface prosthesis on wavefront higher-order aberrations","volume":"151","author":"Gumus","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R45-20260422","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1097\/ICL.0b013e31824daa5e","article-title":"Jupiter scleral lenses: The UC davis eye center experience","volume":"38","author":"Pecego","year":"2012","journal-title":"Eye Contact Lens"},{"key":"R46-20260422","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1097\/OPX.0000000000001228","article-title":"Clinical performance of a new bitangential mini-scleral lens","volume":"95","author":"Otten","year":"2018","journal-title":"Optom Vis Sci Off Publ Am Acad Optom"},{"key":"R47-20260422","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.4103\/ijo.IJO_936_19","article-title":"A new technique for fitting of tricurve rigid gas-permeable contact lens in penetrating keratoplasty eyes using Scheimpflug imaging","volume":"68","author":"Gogri","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R48-20260422","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/01.icl.0000191953.84449.d6","article-title":"Incidence of rigid gas-permeable contact lens wear after keratoplasty for keratoconus","volume":"32","author":"Geerards","year":"2006","journal-title":"Eye Contact Lens"},{"key":"R49-20260422","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1097\/00003226-200005000-00012","article-title":"Reverse geometry contact lens wear after photorefractive keratectomy, radial keratotomy, or penetrating keratoplasty","volume":"19","author":"Lim","year":"2000","journal-title":"Cornea"},{"key":"R50-20260422","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.clae.2003.12.001","article-title":"Management options for the flat corneal graft","volume":"27","author":"Lagnado","year":"2004","journal-title":"Contact Lens Anterior Eye"},{"key":"R51-20260422","first-page":"29","article-title":"A new biaspheric contact lens for severe astigmatism following penetrating keratoplasty","volume":"18","author":"Weiner","year":"1992","journal-title":"CLAO J"},{"key":"R52-20260422","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.clae.2013.07.015","article-title":"Bitoric rigid gas permeable contact lenses in the optical management of penetrating keratoplasty","volume":"37","author":"Phan","year":"2014","journal-title":"Contact Lens Anterior Eye"},{"key":"R53-20260422","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1136\/bjo.2005.069500","article-title":"Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome","volume":"89","author":"Gruenauer-Kloevekorn","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"R54-20260422","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.clae.2019.06.002","article-title":"Effects of a semi-scleral contact lens on refraction and higher order aberrations","volume":"42","author":"Kumar","year":"2019","journal-title":"Contact Lens Anterior Eye"},{"key":"R55-20260422","first-page":"1703","article-title":"Effect of gas-permeable contact lenses on the endothelium of corneal transplants","volume":"109","author":"Speaker","year":"1991","journal-title":"Arch Ophthalmol Chic Ill 1960"},{"key":"R56-20260422","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/01.icl.0000233217.68379.d5","article-title":"Modern scleral lenses part I: Clinical features","volume":"33","author":"Visser","year":"2007","journal-title":"Eye Contact Lens"},{"key":"R57-20260422","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jcjo.2016.07.008","article-title":"Patient comfort and visual outcomes of mini-scleral contact lenses","volume":"52","author":"Yan","year":"2017","journal-title":"Can J Ophthalmol"},{"key":"R58-20260422","first-page":"17","article-title":"Visual rehabilitation using mini-scleral contact lenses after penetrating keratoplasty","volume":"80","author":"Rocha GA do","year":"2017","journal-title":"Arq Bras Oftalmol"},{"key":"R59-20260422","first-page":"14","article-title":"Management of irregular astigmatism with rigid gas permeable contact lenses","volume":"26","author":"Jupiter","year":"2000","journal-title":"CLAO J"},{"key":"R60-20260422","first-page":"184","article-title":"A bitoric gas permeable hard contact lens with spherical power effect","volume":"56","author":"Sarver","year":"1985","journal-title":"J Am Optom Assoc"},{"key":"R61-20260422","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1097\/ICL.0b013e31829e8faa","article-title":"Wearing time as a measure of success of scleral lenses for patients with irregular astigmatism","volume":"39","author":"Ortenberg","year":"2013","journal-title":"Eye Contact Lens"},{"key":"R62-20260422","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S0892-8967(01)00041-4","article-title":"Complexity of contact lens fitting following penetrating keratoplasty","volume":"26","author":"Ho","year":"1999","journal-title":"Int Contact Lens Clin N Y N"},{"key":"R63-20260422","doi-asserted-by":"crossref","first-page":"12.","DOI":"10.1186\/s12886-023-02769-9","article-title":"Investigation of contrast visual acuity with rigid gas permeable contact lenses after penetrating Keratoplasty","volume":"23","author":"Zhang","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"R64-20260422","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1097\/ICL.0000000000000755","article-title":"Efficiency and safety of scleral lenses in rehabilitation of refractive errors and high order aberrations after penetrating keratoplasty","volume":"47","author":"Penbe","year":"2021","journal-title":"Eye Contact Lens"},{"key":"R65-20260422","first-page":"64","article-title":"Topographic stability and safety of contact lens use after penetrating keratoplasty","volume":"22","author":"Gomes","year":"1996","journal-title":"CLAO J"},{"key":"R66-20260422","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.clae.2014.08.002","article-title":"Corneal changes following short-term miniscleral contact lens wear","volume":"37","author":"Vincent","year":"2014","journal-title":"Contact Lens Anterior Eye"},{"key":"R67-20260422","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/ICL.0000000000000534","article-title":"Anterior corneal curvature and aberration changes after scleral lens wear in keratoconus patients with and without ring segments","volume":"45","author":"Serramito-Blanco","year":"2019","journal-title":"Eye Contact Lens"},{"key":"R68-20260422","first-page":"183","article-title":"Corneal topography in contact lens wearers following penetrating keratoplasty","volume":"21","author":"Sperber","year":"1995","journal-title":"CLAO J"},{"key":"R69-20260422","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1097\/00140068-200301000-00011","article-title":"RK4 (reverse-geometry) contact lens fitting after penetrating keratoplasty","volume":"29","author":"Lin","year":"2003","journal-title":"Eye Contact Lens"},{"key":"R70-20260422","first-page":"265","article-title":"Effects of long-term rigid contact lens wear on the endothelium of corneal transplants for keratoconus 10 years after penetrating keratoplasty","volume":"21","author":"Bourne","year":"1995","journal-title":"CLAO J"},{"key":"R71-20260422","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1016\/j.clae.2018.05.004","article-title":"Corneal oedema in a unilateral corneal graft patient induced by high Dk mini-scleral contact lens","volume":"41","author":"Guillon","year":"2018","journal-title":"Contact Lens Anterior Eye"},{"key":"R72-20260422","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1097\/OPX.0000000000001571","article-title":"Scleral lens-induced corneal edema after penetrating keratoplasty","volume":"97","author":"Kumar","year":"2020","journal-title":"Optom Vis Sci Off Publ Am Acad Optom"},{"key":"R73-20260422","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1097\/ICL.0000000000000610","article-title":"Treatment limitations with PROSE (Prosthetic Replacement of the Ocular Surface Ecosystem): One centers experience","volume":"45","author":"Schear","year":"2019","journal-title":"Eye Contact Lens"},{"key":"R74-20260422","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.clae.2021.02.010","article-title":"CLEAR-Contact lens complications","volume":"44","author":"Stapleton","year":"2021","journal-title":"Contact Lens Anterior Eye"},{"key":"R75-20260422","first-page":"59","article-title":"Suction cup\/contact lens complications following penetrating keratoplasty","volume":"24","author":"Ingraham","year":"1998","journal-title":"CLAO J"},{"key":"R76-20260422","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.clae.2012.07.004","article-title":"Predicting estimates of oxygen transmissibility for scleral lenses","volume":"35","author":"Michaud","year":"2012","journal-title":"Contact Lens Anterior Eye"},{"key":"R77-20260422","doi-asserted-by":"crossref","first-page":"2162","DOI":"10.1016\/S0161-6420(03)00659-6","article-title":"Impact of graft diameter on corneal power and the regularity of postkeratoplasty astigmatism before and after suture removal","volume":"110","author":"Seitz","year":"2003","journal-title":"Ophthalmology"},{"key":"R78-20260422","first-page":"239","article-title":"Alcaligenes xylosoxidans keratitis post penetrating keratoplasty in a rigid gas permeable lens wearer","volume":"24","author":"Lin","year":"1998","journal-title":"CLAO J"},{"key":"R79-20260422","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1016\/j.ophtha.2007.01.008","article-title":"Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor","volume":"114","author":"Pantanelli","year":"2007","journal-title":"Ophthalmology"},{"key":"R80-20260422","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1097\/ICO.0000000000000798","article-title":"Clinical Features, Antibiotic Susceptibility Profiles, and Outcomes of Infectious Keratitis Caused by Achromobacter xylosoxidans","volume":"35","author":"Spierer","year":"2016","journal-title":"Cornea"},{"key":"R81-20260422","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1097\/OPX.0000000000001245","article-title":"Case series: Corneal epithelial macrocysts in scleral contact lenses post-penetrating keratoplasty","volume":"95","author":"Nguyen","year":"2018","journal-title":"Optom Vis Sci Off Publ Am Acad Optom"},{"key":"R82-20260422","first-page":"169","article-title":"Time to resolution of contact lens-induced corneal warpage prior to refractive surgery","volume":"28","author":"Wang","year":"2002","journal-title":"CLAO J"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2394_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:55:22Z","timestamp":1786647322000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2394_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":81,"journal-issue":{"issue":"Suppl 3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2394_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"assertion":[{"value":"2024-10-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}