{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:32:35Z","timestamp":1786649555730,"version":"build-2736575974"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 3","license":[{"start":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T00:00:00Z","timestamp":1744848000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study aims to compare the visual and refractive outcomes of two new aspheric intraocular lenses (IOLs), that is, Clareon (Model CNA0T0) and Tecnis Eyhance (Model ICB00), in patients undergoing phacoemulsification cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A retrospective comparative analysis was conducted at a tertiary referral institute in South India. A total of 132 eyes (91 patients) were included, with 66 eyes implanted with Clareon IOL (group 1) and 66 eyes with Tecnis Eyhance IOL (group 2). Preoperative and postoperative data were collected from January 2022 to April 2024. Primary outcomes included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), spherical equivalent, and refractive cylinder, measured at 3 weeks postoperatively. Statistical analysis was performed using an independent sample\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test and Statistical Package for the Social Sciences software, with\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      values &lt;0.05 considered significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean log of minimum angle of resolution (logMAR) UDVA in group 1 was 0.14 (95% confidence interval [CI] [0.11, 0.17]) and in group 2 was 0.16 (95% CI [0.13, 0.19]) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      value 0.16). The mean logMAR UNVA in group 1 was M = 0.55 (95% CI [0.53, 0.58]) and in group 2 was M = 0.5 (95% CI [0.48, 0.52]) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      value 0.0006). The mean add required for group 1 was + 1.76 (95% CI [1.66, 1.86]) and for group 2 was M = 1.56 (95% CI [1.49, 1.62]) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      value 0.0005).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>At 3 weeks postoperatively, both IOLs provided excellent visual outcomes. Tecnis Eyhance IOL offered enhanced near-vision performance.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2395_24","type":"journal-article","created":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T07:00:12Z","timestamp":1744873212000},"page":"S418-S423","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of clinical outcomes of phacoemulsification with implantation of two new aspheric intraocular lenses: Real-world data"],"prefix":"10.4103","volume":"73","author":[{"given":"Shikha Talwar","family":"Bassi","sequence":"first","affiliation":[{"name":"Department of Neuroophthalmology Services, Sankara Nethralaya, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,17]]},"reference":[{"key":"R1-20260422","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1097\/j.jcrs.0000000000001173","article-title":"Three-year multinational clinical study on an aspheric hydrophobic acrylic intraocular lens","volume":"49","author":"Nuijts","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R2-20260422","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1097\/j.jcrs.0000000000001239","article-title":"Comparative analysis of visual outcomes with 2 enhanced monofocal intraocular lenses","volume":"49","author":"Corbelli","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R3-20260422","doi-asserted-by":"crossref","first-page":"3983","DOI":"10.2147\/OPTH.S444696","article-title":"Head-to-head comparison of intermediate vision of two monofocal intraocular lenses","volume":"17","author":"Micheletti","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R4-20260422","doi-asserted-by":"crossref","first-page":"22.","DOI":"10.1186\/s40662-021-00245-3","article-title":"Lens thickness and associated ocular biometric factors among cataract patients in Shanghai","volume":"8","author":"Meng","year":"2021","journal-title":"Eye Vis (Lond)"},{"key":"R5-20260422","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1080\/02713683.2024.2316717","article-title":"Influence of lens thickness on accuracy of kane, Hill-RBF 3.0, barrett universal ii, emmetropia verifying optical, and pearl-DGS formulas in eyes with nonhigh myopia and high myopia","volume":"49","author":"Chen","year":"2024","journal-title":"Curr Eye Res"},{"key":"R6-20260422","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.2147\/OPTH.S295008","article-title":"Effectiveness and safety of the clareon monofocal intraocular lens: Outcomes from a 12-month single-arm clinical study in a large sample","volume":"15","author":"Lehmann","year":"2021","journal-title":"Clin Ophthalmol"},{"key":"R7-20260422","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.2147\/OPTH.S415400","article-title":"Evaluation of visual outcomes and 3-month refractive stability of a new hydrophobic acrylic intraocular lens","volume":"17","author":"Blehm","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R8-20260422","doi-asserted-by":"crossref","first-page":"181","DOI":"10.4103\/IJO.IJO_681_23","article-title":"Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses","volume":"72","author":"Singh","year":"2024","journal-title":"Indian J Ophthalmol"},{"key":"R9-20260422","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jcrs.2008.09.027","article-title":"Prevalence of corneal astigmatism before cataract surgery","volume":"35","author":"Ferrer-Blasco","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R10-20260422","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/j.jcrs.0000000000000399","article-title":"Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract","volume":"47","author":"Auffarth","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260422","doi-asserted-by":"crossref","first-page":"112.","DOI":"10.1007\/s10792-024-02946-9","article-title":"Visual outcomes and patient satisfaction after bilateral implantation of an enhanced monofocal intraocular lens: A single-masked prospective randomized study","volume":"44","author":"Giglio","year":"2024","journal-title":"Int Ophthalmol"},{"key":"R12-20260422","doi-asserted-by":"crossref","first-page":"2867","DOI":"10.4103\/ijo.IJO_2921_21","article-title":"Comparison of clinical outcomes of trifocal intraocular lens (AT LISA, Eyecryl SERT trifocal) versus extended depth of focus intraocular lens (Eyhance, Eyecryl SERT EDOF)","volume":"70","author":"Karuppiah","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"R13-20260422","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1055\/a-1773-1197","article-title":"Benchmarking visual performance with monofocal intraocular lenses with and without enhanced optical properties in a nighttime driving simulator environment: A proof-of-concept study","volume":"239","author":"Ungewiss","year":"2022","journal-title":"Klin Monbl Augenheilkd"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2395_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:55:21Z","timestamp":1786647321000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2395_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,17]]},"references-count":13,"journal-issue":{"issue":"Suppl 3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2395_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,17]]},"assertion":[{"value":"2024-10-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}