{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:31:01Z","timestamp":1786649461716,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T00:00:00Z","timestamp":1766966400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate the refractive outcomes of cataract surgery in eyes with previous myopic corneal refractive surgery using total keratometry (TK) and the Barrett True-K No History method for intraocular lens (IOL) power calculation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>Four clinical centers in India.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Ambispective case series.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      All eyes had previously undergone either myopic photorefractive keratectomy (PRK) or laser\n                      <jats:italic toggle=\"yes\">in situ<\/jats:italic>\n                      keratomileusis (LASIK) and underwent cataract surgery with monofocal IOL implantation. Before surgery, TK and standard keratometry (K) were measured with the IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany), while simulated keratometry (Sim K) was measured with the Pentacam HR (Oculus). IOL power calculations were performed with the Barrett True-K No History with TK. Prediction errors (PEs) and median absolute errors (MAEs) were calculated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 35 patients were included. The MAE and mean PE with the Barrett True-K No History with TK (0.42 \u00b1 0.34 D, 0.01 \u00b1 0.54 D) were more accurate compared to the Barrett True-K No History with K (0.47 \u00b1 0.43 D, 0.11 \u00b1 0.63 D), Barrett True-K No History with Sim K (0.68 \u00b1 0.79 D, -0.30 \u00b1 1.00 D), Haigis with TK (0.70 \u00b1 0.57 D, -0.56 \u00b1 0.71 D), and Haigis L with K (0.59 \u00b1 0.45 D; 0.20 \u00b1 0.72 D), all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>In eyes with previous myopic PRK and LASIK, the combination of the Barrett True-K No History with TK from the IOLMaster 700 allowed for improved refractive outcomes, with the highest percentage of eyes achieving the target refraction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2404_24","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T15:00:19Z","timestamp":1767020419000},"page":"44-47","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Total keratometry for intraocular lens power calculation in eyes with previous myopic corneal refractive surgery"],"prefix":"10.4103","volume":"74","author":[{"given":"Abhay R","family":"Vasavada","sequence":"first","affiliation":[{"name":"Raghudeep Eye Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shail","family":"Vasavada","sequence":"additional","affiliation":[{"name":"Raghudeep Eye Hospital, Ahmedabad, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashvin","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Dr. Agarwal\u2019s Eye Hospital, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haripriya","family":"Aravind","sequence":"additional","affiliation":[{"name":"Aravind Eye Hospital, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheetal","family":"Brar","sequence":"additional","affiliation":[{"name":"Nethradhama Superspeciality Eye Hospital, Bangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sri","family":"Ganesh","sequence":"additional","affiliation":[{"name":"Nethradhama Superspeciality Eye Hospital, Bangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,29]]},"reference":[{"key":"R1-20260420","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of intraocular lens calculation formulas","volume":"125","author":"Melles","year":"2018","journal-title":"Ophthalmology"},{"key":"R2-20260420","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.jcrs.2016.07.021","article-title":"Intraocular lens power formula accuracy: Comparison of 7 formulas","volume":"42","author":"Kane","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R3-20260420","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40662-018-0110-5","article-title":"Intraocular lens power calculation in eyes with previous corneal refractive surgery","volume":"5","author":"Savini","year":"2018","journal-title":"Eye Vis (Lond)"},{"key":"R4-20260420","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.ophtha.2020.10.031","article-title":"Intraocular lens power calculation in eyes with previous excimer laser surgery for myopia: A report by the american academy of ophthalmology","volume":"128","author":"Pantanelli","year":"2021","journal-title":"Ophthalmology"},{"key":"R5-20260420","first-page":"25158414221118524","article-title":"Intraocular lens power calculation in eyes with previous corneal refractive surgery","volume":"14","author":"Anders","year":"2022","journal-title":"Ther Adv Ophthalmol"},{"key":"R6-20260420","doi-asserted-by":"crossref","first-page":"862","DOI":"10.3928\/1081597X-20090917-07","article-title":"Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery","volume":"25","author":"Holladay","year":"2009","journal-title":"J Refract Surg"},{"key":"R7-20260420","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1097\/j.jcrs.0000000000000551","article-title":"Ocular biometry with swept-source optical coherence tomography","volume":"47","author":"Mont\u00e9s-Mic\u00f3","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R8-20260420","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","article-title":"Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery","volume":"45","author":"Wang","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260420","doi-asserted-by":"crossref","first-page":"e121","DOI":"10.1016\/j.ophtha.2020.06.054","article-title":"Intraocular lens power calculations in eyes with previous corneal refractive surgery: Review and expert opinion","volume":"128","author":"Wang","year":"2021","journal-title":"Ophthalmology"},{"key":"R10-20260420","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1097\/00003226-200111000-00003","article-title":"Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia: A standardized approach","volume":"20","author":"Feiz","year":"2001","journal-title":"Cornea"},{"key":"R11-20260420","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.jcrs.2005.12.106","article-title":"Simple regression formula for intraocular lens power adjustment in 473 eyes requiring cataract surgery after excimer laser photoablation","volume":"32","author":"Masket","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260420","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/S0002-9394(03)00275-7","article-title":"Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis","volume":"136","author":"Shammas","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R13-20260420","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","article-title":"Accuracy of the barrett true-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia","volume":"42","author":"Abulafia","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R14-20260420","doi-asserted-by":"crossref","first-page":"1658","DOI":"10.1016\/j.jcrs.2008.06.029","article-title":"Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula","volume":"34","author":"Haigis","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R15-20260420","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1111\/ceo.13760","article-title":"Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery","volume":"48","author":"Lawless","year":"2020","journal-title":"Clin Exp Ophthalmol"},{"key":"R16-20260420","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/j.jcrs.0000000000001300","article-title":"Performance of IOL calculation formulas that use measured posterior corneal power in eyes following myopic laser vision correction","volume":"50","author":"Kenny","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"R17-20260420","doi-asserted-by":"crossref","first-page":"54","DOI":"10.3928\/1081597X-20181119-01","article-title":"Evaluation of different IOL calculation formulas of the ASCRS calculator in eyes after corneal refractive laser surgery for myopia with multifocal IOL implantation","volume":"35","author":"Vrijman","year":"2019","journal-title":"J Refract Surg"},{"key":"R18-20260420","doi-asserted-by":"crossref","first-page":"26560","DOI":"10.1038\/s41598-024-78266-w","article-title":"Accuracy of recent intraocular lens power calculation methods in post-myopic LASIK eyes","volume":"14","author":"Gettinger","year":"2024","journal-title":"Sci Rep"},{"key":"R19-20260420","doi-asserted-by":"crossref","first-page":"848","DOI":"10.3928\/1081597X-20211213-01","article-title":"Comparison of corneal power calculation by standard keratometry and total keratometry in eyes with previous myopic FS-LASIK","volume":"37","author":"Lupardi","year":"2021","journal-title":"J Refract Surg"},{"key":"R20-20260420","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1097\/j.jcrs.0000000000001139","article-title":"Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE","volume":"49","author":"Elotmani","year":"2023","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2404_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:54:27Z","timestamp":1786647267000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2404_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,29]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2404_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,29]]},"assertion":[{"value":"2024-10-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}