{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:41:07Z","timestamp":1787071267248,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","license":[{"start":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T00:00:00Z","timestamp":1773273600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:p>Foldable acrylic lenses are the most extensively used \u2018in the bag\u2019 monofocal or multifocal intraocular lenses (IOLs) in cataract surgery, toric lenses in astigmatism, and refractive lens exchange surgeries. When subluxation or dislocation of these lenses is encountered, they must be explanted as they cannot be fixed with conventional scleral fixation techniques. The \u2018pierce\u2019 technique is a novel way of fixing these lenses to the sclera, wherein a 9-0\/10-0 polypropylene suture with a straight needle is passed through the IOL at the haptic-optic junction. The ends of the threads are sutured under the scleral flaps in a vertical fashion. This case series highlights the merits of refixing subluxated or dislocated IOLs in a closed or open globe technique and its utility in eyes with weakened capsular bags as it provides good centration, minimal tilt, and applicability to a wider range of foldable IOLs without eyelets, including premium IOLs.<\/jats:p>","DOI":"10.4103\/ijo.ijo_2536_25","type":"journal-article","created":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T16:02:01Z","timestamp":1773331321000},"page":"S142-S147","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Modified ab externo 2-point pierce technique for scleral fixation of single-piece intraocular lenses"],"prefix":"10.4103","volume":"74","author":[{"given":"Karishma","family":"Tendulkar","sequence":"first","affiliation":[{"name":"Department of Vitreo-Retina, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nagesha C","family":"Krishnappa","sequence":"additional","affiliation":[{"name":"Department of Vitreo-Retina, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohitha","family":"Nayak","sequence":"additional","affiliation":[{"name":"Department of Phaco and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaitra","family":"Jayadev","sequence":"additional","affiliation":[{"name":"Department of Vitreo-Retina, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naren","family":"Shetty","sequence":"additional","affiliation":[{"name":"Department of Phaco and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,12]]},"reference":[{"key":"R1-20260430","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.ajo.2018.10.020","article-title":"Frequency of intraocular lens dislocation and pseudophacodonesis, 20 Years after cataract surgery-A prospective study","volume":"198","author":"M\u00f6nestam","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"R2-20260430","doi-asserted-by":"crossref","first-page":"2317","DOI":"10.2147\/OPTH.S205148","article-title":"Intraocular lens implantation in the ciliary sulcus: Challenges and risks","volume":"13","author":"Mehta","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"R3-20260430","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1016\/j.jcrs.2011.07.003","article-title":"Cupid fixation for repositioning a subluxated intraocular lens","volume":"37","author":"Domingues","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R4-20260430","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1097\/j.jcrs.0000000000000260","article-title":"Adjustable 6 and 0 polypropylene flanged technique for scleral fixation, part 1: Primary fixation IOLs in aphakia, capsular stabilizing devices, and aniridia implants","volume":"46","author":"Assia","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R5-20260430","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S0886-3350(99)00393-4","article-title":"Ab externo 4-point scleral fixation","volume":"26","author":"Rao","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R6-20260430","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2007.07.013","article-title":"Sutureless intrascleral posterior chamber intraocular lens fixation","volume":"33","author":"Gabor","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R7-20260430","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R8-20260430","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/j.jcrs.0000000000000845","article-title":"Punch and rescue technique for scleral fixation of dislocated single-piece intraocular lenses","volume":"48","author":"Micheletti","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260430","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1186\/s12886-023-03133-7","article-title":"Four-flanged polypropylene optic piercing technique for scleral fixation of multifocal intraocular lens","volume":"23","author":"Eom","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"R10-20260430","doi-asserted-by":"crossref","first-page":"e00042","DOI":"10.1097\/j.jcro.0000000000000042","article-title":"Endophthalmitis associated with flange exposure after a 4-flanged canabrava fixation technique","volume":"9","author":"Roditi","year":"2021","journal-title":"JCRS Online Case Rep"},{"key":"R11-20260430","doi-asserted-by":"crossref","first-page":"e00058","DOI":"10.1097\/j.jcro.0000000000000058","article-title":"Exposed polypropylene flange in the Canabrava double-flanged polypropylene technique","volume":"9","author":"Canabrava","year":"2021","journal-title":"JCRS Online Case Rep"},{"key":"R12-20260430","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1177\/2474126417690650","article-title":"Scleral-fixated intraocular lenses: Past and present","volume":"1","author":"Stem","year":"2017","journal-title":"J Vitreoretin Dis"},{"key":"R13-20260430","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ajo.2005.09.012","article-title":"Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation","volume":"141","author":"Vote","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R14-20260430","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2004.12.060","article-title":"Late dislocation of scleral-sutured posterior chamber intraocular lenses","volume":"31","author":"Price","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R15-20260430","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2004.12.060","article-title":"Late dislocation of scleral-sutured posterior chamber intraocular lenses","volume":"31","author":"Price","year":"2005","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2536_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:43:55Z","timestamp":1787067835000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2536_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,12]]},"references-count":15,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2536_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,12]]},"assertion":[{"value":"2025-10-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}