{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:30:13Z","timestamp":1786649413817,"version":"build-2736575974"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To investigate the efficacy and safety of a modified dual-incision ophthalmic viscosurgical device-free (OVD-free) method for implantable collamer lens (ICL) implantation in high myopic eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 68 participants were enrolled in this prospective randomized clinical trial, including 33 in the OVD-free group and 35 in the standard group. Operation time and intraocular pressure (IOP) at 2 hours postoperatively were recorded. Visual acuity, refractive power, IOP, corneal endothelium parameters, and anterior segment parameters were assessed at 1 day, 1 week, 1 month, 3 months, and 6 months postoperatively. Postoperative subjective visual quality at 3 months was recorded through a Quality of Vision (QoV) questionnaire.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>No significant differences in visual acuity, refractive outcomes, and corneal endothelial parameters were found, while the operation time was significantly shorter in the OVD-free group. Both groups showed a significant increase in IOP at 2 hours after surgery, but the increase in the OVD-free group was significantly smaller than that in the standard group. In addition, the frequency of ring-shaped dysphotopsia in the OVD-free group (15.15%) was significantly lower than that in the standard group (40%), and the severity and annoyance of this symptom were also significantly lower in the OVD-free group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The modified OVD-free ICL implantation is a safe, effective, and predictable method for myopia correction, which could be a better choice for short surgery time, better subjective visual perception, and low occurrence of IOP elevation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_2859_23","type":"journal-article","created":{"date-parts":[[2024,5,20]],"date-time":"2024-05-20T11:01:35Z","timestamp":1716202895000},"page":"1291-1297","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Clinical outcomes of a modified ophthalmic viscosurgical device-free implantable collamer lens implantation"],"prefix":"10.4103","volume":"72","author":[{"given":"Chuqiao","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Shanghai Ninth People\u2019s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Department of Ophthalmology, Shanghai Tenth People\u2019s Hospital Affiliated to Tongji University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Shanghai Ninth People\u2019s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qimin","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Shanghai Key Laboratory of Tissue Engineering, Shanghai Ninth People\u2019s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Shanghai Ninth People\u2019s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jibo","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Shanghai Ninth People\u2019s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,5,20]]},"reference":[{"key":"R1-20260427","first-page":"1036","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"R2-20260427","first-page":"1946.","article-title":"Dietary patterns and associations with myopia in Chinese children","volume":"15","author":"Yin","year":"2023","journal-title":"Nutrients"},{"key":"R3-20260427","first-page":"1053206.","article-title":"Implementing interventions to promote spectacle wearing among children with refractive errors: A systematic review and meta-analysis","volume":"11","author":"Wu","year":"2023","journal-title":"Front Public Health"},{"key":"R4-20260427","first-page":"532","article-title":"Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia","volume":"157","author":"Igarashi","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R5-20260427","first-page":"1683","article-title":"United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia: Three-year follow-up","volume":"111","author":"Sanders","year":"2004","journal-title":"Ophthalmology"},{"key":"R6-20260427","first-page":"409","article-title":"Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopia","volume":"96","author":"Shimizu","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"R7-20260427","first-page":"50","article-title":"Ophthalmic viscosurgical devices","volume":"19","author":"Bissen-Miyajima","year":"2008","journal-title":"Curr Opin Ophthalmol"},{"key":"R8-20260427","first-page":"259","article-title":"Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia","volume":"36","author":"Almalki","year":"2016","journal-title":"Int Ophthalmol"},{"key":"R9-20260427","first-page":"e0165469","article-title":"Etiology and management of raised intraocular pressure following posterior chamber phakic intraocular lens implantation in myopic eyes","volume":"11","author":"Senthil","year":"2016","journal-title":"PLoS One"},{"key":"R9-20260427","first-page":"e0172929","article-title":"Erratum","volume":"12","year":"2017","journal-title":"PLoS One"},{"key":"R10-20260427","first-page":"765","article-title":"Implantable collamer posterior chamber intraocular lenses: A review of potential complications","volume":"27","author":"Fernandes","year":"2011","journal-title":"J Refract Surg"},{"key":"R11-20260427","first-page":"781","article-title":"Lens opacities after posterior chamber phakic intraocular lens implantation","volume":"110","author":"S\u00e1nchez-Galeana","year":"2003","journal-title":"Ophthalmology"},{"key":"R12-20260427","first-page":"764653.","article-title":"Safety of EVO ICL implantation with an ophthalmic viscosurgical device-free technique in the early 24 h after surgery","volume":"8","author":"Zhang","year":"2021","journal-title":"Front Med (Lausanne)"},{"key":"R13-20260427","first-page":"18.","article-title":"A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer","volume":"7","author":"Pan","year":"2020","journal-title":"Eye Vis (Lond)"},{"key":"R14-20260427","first-page":"e20691","article-title":"Safety of implantable collamer lens implantation without ophthalmic viscosurgical device: A retrospective cohort study","volume":"99","author":"Peng","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"R15-20260427","first-page":"198","article-title":"Comparison of clinical outcomes of implantable collamer lens implantation with and without use of an ophthalmic viscosurgical device","volume":"47","author":"Kim","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R16-20260427","first-page":"790137","article-title":"One-year observation of safety of implantable collamer lens V4c implantation without using an ophthalmic viscosurgical device","volume":"9","author":"Chen","year":"2022","journal-title":"Front Med (Lausanne)"},{"key":"R17-20260427","first-page":"7363267.","article-title":"Pure ICL Implantation: A novel ophthalmic viscosurgical device-free method","volume":"2021","author":"Qin","year":"2021","journal-title":"J Ophthalmol"},{"key":"R18-20260427","first-page":"5537","article-title":"The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire","volume":"51","author":"McAlinden","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R19-20260427","first-page":"117","article-title":"Effect of the EVO+visian phakic implantable collamer lens on visual performance and quality of vision and life","volume":"226","author":"Mart\u00ednez-Plaza","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R20-20260427","first-page":"177","article-title":"Posterior chamber phakic intraocular lens implantation: Comparative, multicentre study in 351 eyes with low-to-moderate or high myopia","volume":"102","author":"Kamiya","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R21-20260427","first-page":"915","article-title":"Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction","volume":"39","author":"Alfonso","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R22-20260427","first-page":"1153","article-title":"Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct myopia: One-year follow-up","volume":"41","author":"Lisa","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R23-20260427","first-page":"1859","article-title":"Intraocular pressure during the early postoperative period after 100 consecutive implantations of posterior chamber phakic intraocular lenses with a central hole","volume":"39","author":"Gonzalez-Lopez","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R24-20260427","first-page":"135","article-title":"Risk factors associated with night vision disturbances after phakic intraocular lens implantation","volume":"157","author":"Lim","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R25-20260427","first-page":"e7294","article-title":"Comparison of implantable collamer lens visian ICL V4 and ICL V4c for high myopia: A cohort study","volume":"96","author":"Tian","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R26-20260427","first-page":"e170","article-title":"Ring-shaped dysphotopsia associated with posterior chamber phakic implantable collamer lenses with a central hole","volume":"95","author":"Eom","year":"2017","journal-title":"Acta Ophthalmol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2859_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:53:51Z","timestamp":1786647231000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_2859_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,20]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_2859_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,20]]},"assertion":[{"value":"2023-10-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-03-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}