{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:41:10Z","timestamp":1787071270082,"version":"build-2736575974"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","license":[{"start":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T00:00:00Z","timestamp":1773273600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare cataract images obtained using portable slit-lamp devices with those taken from the standard slit-lamp built-in camera.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective, single-center, comparative digital imaging validation study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 198 slit-lamp images were taken from 66 patients with cataracts using a smartphone slit-lamp prototype (\u201cMIDAS\u201d), a tablet with a portable slit-lamp (\u201cI.C.P.\u201d), and a slit-lamp with a custom-mounted digital camera (\u201cASC\u201d). An ophthalmologist, an optometrist, and a family medicine resident independently graded the images according to Nuclear Opalescence (NO) and Nuclear Colour (NC) of the Lens Opacities Classification System III. The intraclass correlation (ICC) for the devices was calculated. Graders\u2019 confidence and subjective assessment of image quality were assessed through a 5-point Likert scale questionnaire.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>For NO, ICC was fair for MIDAS (0.619, 95% confidence interval [95% CI] = 0.426 to 0.754) and I.C.P. (0.585, 95% CI = 0.373 to 0.733) but poor for ASC (0.394, 95% CI = 0.088 to 0.609). For NC, ICC was excellent for all (MIDAS, 0.837, 95% CI = 0.755 to 0.895; I.C.P., 0.851, 95% CI = 0.775 to 0.904; ASC, 0.892, 95% CI = 0.837 to 0.930). Grader confidence was the highest for ASC images (85.5%), followed by I.C.P. (69.1%) and MIDAS (65.6%). Subjective assessment of image quality was the highest for ASC images (96.5%), followed by I.C.P. (77.3%) and MIDAS (74.2%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Portable slit-lamp devices had excellent ICC for assessing NC and fair ICC for assessing NO. Graders expressed greater confidence and higher perceived image quality for the standard slit-lamp built-in camera.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_3037_24","type":"journal-article","created":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T16:02:07Z","timestamp":1773331327000},"page":"S59-S65","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of a mobile imaging device for anterior segment (MIDAS) with a commercially available portable and conventional slit-lamp imaging for cataract photography"],"prefix":"10.4103","volume":"74","author":[{"given":"Dayna W W","family":"Yong","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, National University Hospital, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Sheng","sequence":"additional","affiliation":[{"name":"Department of Biostatistics, Singapore Clinical Research Institute, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rubin HS","family":"Yong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, National University Hospital, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Z","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, National University Hospital, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,12]]},"reference":[{"key":"R4-20260430","doi-asserted-by":"crossref","first-page":"6","DOI":"10.47102\/annals-acadmedsg.V45N1p6","article-title":"Smartphone imaging in ophthalmology: A comparison with traditional methods on the reproducibility and usability for anterior segment imaging","volume":"45","author":"Chen","year":"2016","journal-title":"Ann Acad Med Singap"},{"key":"R5-20260430","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The lens opacities classification system III","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"R6-20260430","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1001\/archopht.1989.01070020053028","article-title":"Lens opacities classification system II (LOCS II)","volume":"107","author":"Chylack","year":"1989","journal-title":"Arch Ophthalmol"},{"key":"R8-20260430","doi-asserted-by":"crossref","first-page":"1748","DOI":"10.1016\/j.ophtha.2006.12.010","article-title":"Web-based grading of compressed stereoscopic digital photography versus standard slide film photography for the diagnosis of diabetic retinopathy","volume":"114","author":"Rudnisky","year":"2007","journal-title":"Ophthalmology"},{"key":"R9-20260430","first-page":"792","article-title":"Rule of thumb for interpreting the size of a correlation coefficient","volume":"5","author":"Hinkle","year":"2003","journal-title":"Appl Stat Behav Sci"},{"key":"R10-20260430","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1111\/cxo.12381","article-title":"Tele-manufactured affordable smartphone anterior segment microscope","volume":"99","author":"Chiong","year":"2016","journal-title":"Clin Exp Optom"},{"key":"R11-20260430","first-page":"1132","article-title":"Factors affecting light-adapted pupil size in normal human subjects","volume":"35","author":"Winn","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R12-20260430","doi-asserted-by":"crossref","first-page":"1037689","DOI":"10.1155\/2020\/1037689","article-title":"Portable handheld slit-lamp based on a smartphone camera for cataract screening","volume":"2020","author":"Hu","year":"2020","journal-title":"J Ophthalmol"},{"key":"R13-20260430","first-page":"10","article-title":"Evaluation of nuclear cataract with smartphone-attachable slit-lamp device","author":"Yazu","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"R14-20260430","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1076\/opep.9.2.83.1523","article-title":"A simplified cataract grading system","volume":"9","author":"Thylefors","year":"2002","journal-title":"Ophthalmic Epidemiol"},{"key":"R15-20260430","doi-asserted-by":"crossref","first-page":"e144","DOI":"10.1016\/S2214-109X(20)30489-7","article-title":"Vision Loss Expert Group of the Global Burden of Disease StudyCauses of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: The right to sight: An analysis for the global burden of disease study","volume":"9","year":"2021","journal-title":"Lancet Glob Health"},{"key":"R16-20260430","doi-asserted-by":"crossref","first-page":"1110383","DOI":"10.3389\/fmed.2023.1110383","article-title":"Beyond vision: Cataract and health status in old age, a narrative review","volume":"10","author":"Mencucci","year":"2023","journal-title":"Front Med (Lausanne)"},{"key":"R17-20260430","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1167\/tvst.10.8.29","article-title":"Design and performance characterization of a novel, smartphone-based, portable digital slit lamp for anterior segment screening using telemedicine","volume":"10","author":"Dutt","year":"2021","journal-title":"Transl Vis Sci Technol"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3037_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:43:56Z","timestamp":1787067836000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3037_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,12]]},"references-count":13,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_3037_24","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,12]]},"assertion":[{"value":"2024-12-18","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-02","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}