{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:50:27Z","timestamp":1791359427250,"version":"4.3.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess diagnostic performance of Cirrus Anterior Segment Optical Coherence Tomography (ASOCT) parameters to differentiate gonioscopic grades of narrow angles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective cross sectional study included 100 eyes with clinically diagnosed angle closure disease. Quantitative ASOCT parameters such as angle width, angle opening distance (AOD), trabecular iris space area (TISA) at scleral spur distances of 500 and 750\u00b5m were measured.Shaffer\u2019s grading system was used to grade narrow angles. Area under the receiver operating characteristic curves (AUCs) were generated to assess diagnostic performance of these measurements to differentiate grades of narrow angles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      68 eyes were available for analysis. . Correlation between grade 0\/1 on gonioscopy with 0\u201310\u00b0 on ASOCT was seen in 81.3% of eyes in the nasal angle and 76.1% of eyes in the temporal angle (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), and grade 2 angle with 11\u201320\u00b0 on ASOCT was seen in 80.0% of eyes in the nasal angle and 72.7% eyes in temporal angle (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). AUC for grade 0\/1 and grade 2 angles on gonioscopy was highest for AOD500 nasally (0.80 [95% confidence interval (CI), 0.68\u20130.88]) while temporally, it was highest for TISA500 (0.72 [95% CI, 0.60\u20130.82]). Kappa coefficient between gonioscopy vs ASOCT was found to be 0.57 (95% CI, 0.36\u20130.75) nasally and 0.46 (95% CI, 0.24\u20130.67) temporally.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Discrimination capability of ASOCT parameters appears to be limited for differentiating between various grades of narrow angle. Further studies with larger sample sizes are required to study the utility of ASOCT in this aspect.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_3331_25","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T14:04:19Z","timestamp":1790690659000},"page":"1509-1513","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Diagnostic ability of Cirrus anterior segment optical coherence tomography to differentiate between binary grades of narrow angles seen on gonioscopy"],"prefix":"10.4103","volume":"74","author":[{"given":"Vidya","family":"Chelerkar","sequence":"first","affiliation":[{"name":"Department of Glaucoma, PBMA\u2019s H. V. Desai Eye Hospital, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vidhi","family":"Solanki","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, PBMA\u2019s H. V. Desai Eye Hospital, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"VKS","family":"Kalyani","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, PBMA\u2019s H. V. Desai Eye Hospital, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikita","family":"Patil","sequence":"additional","affiliation":[{"name":"Department of Glaucoma, PBMA\u2019s H. V. Desai Eye Hospital, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"key":"R1-20261007","doi-asserted-by":"crossref","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","article-title":"Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis","volume":"121","author":"Tham","year":"2014","journal-title":"Ophthalmology"},{"key":"R2-20261007","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1016\/S0161-6420(00)00274-8","article-title":"Angle closure glaucoma in an urbanpopulation in Southern India","volume":"107","author":"Dandona","year":"2000","journal-title":"Ophthalmology"},{"key":"R3-20261007","first-page":"81","article-title":"Prevalence of primary glaucoma in an urban south Indian population","volume":"46","author":"Jacob","year":"1998","journal-title":"Indian J Ophthalmol"},{"key":"R4-20261007","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1001\/archopht.124.3.403","article-title":"Prevalence of angle-closure disease in a rural southern Indian population","volume":"124","author":"Vijaya","year":"2006","journal-title":"Arch Ophthalmol"},{"key":"R5-20261007","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1136\/bjo.2005.081224","article-title":"The number of people with glaucoma worldwide in 2010 and 2020","volume":"90","author":"Quigley","year":"2006","journal-title":"Br J Ophthalmol"},{"key":"R6-20261007","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1111\/j.1442-9071.2012.02774.x","article-title":"Angle closure and angle-closure glaucoma: What we are doing now and what we will be doing in the future","volume":"40","author":"Friedman","year":"2012","journal-title":"Clin Experiment Ophthalmol"},{"key":"R7-20261007","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.jcjo.2016.12.010","article-title":"Undetected angle closure in patients with a diagnosis of open-angle glaucoma","volume":"52","author":"Varma","year":"2017","journal-title":"Can J Ophthalmol"},{"key":"R8-20261007","doi-asserted-by":"crossref","first-page":"45","DOI":"10.4103\/0301-4738.37595","article-title":"Understanding and using sensitivity, specificity and predictive values","volume":"56","author":"Parikh","year":"2008","journal-title":"Indian J Ophthalmol"},{"key":"R9-20261007","first-page":"933","article-title":"Repeatability and comparison of anterior chamber angle assessment tests","volume":"55","author":"Campbell","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R11-20261007","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/eye.2010.201","article-title":"Anterior chamber angle imaging wioptical coherence tomography","author":"Leung","year":"2011","journal-title":"Eye 25"},{"key":"R12-20261007","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.survophthal.2013.06.005","article-title":"Application of anterior segment optical coherence tomography in glaucoma","volume":"59","author":"Sharma","year":"2014","journal-title":"Surv Ophthalmol"},{"key":"R13-20261007","first-page":"3352","article-title":"Diagnostic performance of anterior chamber angle measurements in detecting eyes at risk for angle closure-An anterior segment OCT study","volume":"50","author":"Narayanaswamy","year":"2009","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20261007","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.survophthal.2007.10.012","article-title":"Anterior chamber angle assessment techniques","volume":"53","author":"Friedman","year":"2008","journal-title":"Surv Ophthalmol"},{"key":"R15-20261007","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s10384-012-0180-1","article-title":"Hong\u2019s grading for evaluating anterior chamber angle width","volume":"56","author":"Kim","year":"2012","journal-title":"Jpn J Ophthalmol"},{"key":"R16-20261007","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1001\/archophthalmol.2007.46","article-title":"Assessment of the scleral spur in anterior segment optical coherence tomography images","volume":"126","author":"Sakata","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"R17-20261007","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s10384-011-0036-0","article-title":"Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography","volume":"55","author":"Park","year":"2011","journal-title":"Jpn J Ophthalmol"},{"key":"R18-20261007","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ophtha.2006.05.073","article-title":"Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes","volume":"114","author":"Nolan","year":"2007","journal-title":"Ophthalmology"},{"key":"R19-20261007","first-page":"1","article-title":"Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: A systematic review and meta-analysis","volume":"260","author":"Desmond","year":"2022","journal-title":"Arbeitsphysiologie"},{"key":"R20-20261007","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5005\/jp-journals-10078-1354","article-title":"Diagnostic performance of optical coherence tomography and nonspecialist gonioscopy to detect angle closure","volume":"16","author":"Esporcatte","year":"2022","journal-title":"J Curr Glaucoma Pract"},{"key":"R21-20261007","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1001\/archopht.123.8.1053","article-title":"Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles","volume":"123","author":"Radhakrishnan","year":"2005","journal-title":"Arch Ophthalmol"},{"key":"R22-20261007","doi-asserted-by":"crossref","first-page":"XVI","DOI":"10.1016\/j.ajo.2018.01.006","article-title":"Anterior segment imaging for angle closure","volume":"188","author":"Chansangpetch","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R23-20261007","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/j.ophtha.2007.06.030","article-title":"Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle","volume":"115","author":"Sakata","year":"2008","journal-title":"Ophthalmology"},{"key":"R24-20261007","doi-asserted-by":"crossref","first-page":"2380","DOI":"10.1016\/j.ophtha.2015.07.030","article-title":"Anterior segment imaging predicts incident gonioscopic angle closure","volume":"122","author":"Baskaran","year":"2015","journal-title":"Ophthalmology"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3331_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:00:48Z","timestamp":1791356448000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3331_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_3331_25","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]},"assertion":[{"value":"2025-12-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}