{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:42:57Z","timestamp":1786653777669,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive calculator in eyes with prior radial keratotomy (RK) for myopia.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This retrospective study included 25 eyes of 18 patients whose status was post-RK for treatment of myopia, which had undergone cataract extraction with IOL implantation. Prediction error was calculated as the difference between implanted IOL power and predicted power by various formulae available on ASCRS post-refractive calculator. The formulas compared were Humphrey Atlas method, IOLMaster\/Lenstar method, Barrett True-K no-history formula, ASCRS Average power, and ASCRS Maximum power on ASCRS post-refractive calculator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Median absolute errors were the least for Barrett True-K and ASCRS Maximum power, that is, 0.56 (0.25, 1.04) and 0.56 (0.25, 1.06) D, respectively, and that of Atlas method was 1.60 (0.85, 2.28) D. Median arithmetic errors were positive for Atlas, Barrett True-K, ASCRS Average (0.86 [\u22120.17, 1.61], 0.14 [\u22120.22 to 0.54], and 0.23 [\u22120.054, 0.76] D, respectively) and negative for IOLMaster\/Lenstar method and ASCRS Maximum power (\u22120.02 [\u22120.46 to 0.38] and \u2212 0.48 [\u22121.06 to \u2212 0.22] D, respectively). Multiple comparison analysis of Friedman\u2019s test revealed that Atlas formula was significantly different from IOLMaster\/Lenstar, Barrett True-K, and ASCRS Maximum power; ASCRS Maximum power was significantly different from all others (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.00001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In post-RK eyes, Barrett True-K no-history formula and ASCRS Maximum power given by the ASCRS calculator were more accurate than other available formulas, with ASCRS Maximum leading to more myopic outcomes when compared to others.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_3417_22","type":"journal-article","created":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T07:55:13Z","timestamp":1692604513000},"page":"3224-3228","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy"],"prefix":"10.4103","volume":"71","author":[{"given":"Naren","family":"Shetty","sequence":"first","affiliation":[{"name":"Department of Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priyanka","family":"Sathe","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"family":"Aishwarya","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathew","family":"Francis","sequence":"additional","affiliation":[{"name":"Imaging, Biomechanics and Mathematical Modelling Solutions, Narayana Nethralaya Foundation, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Shetty","sequence":"additional","affiliation":[{"name":"Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,8,21]]},"reference":[{"key":"R1-20251008","first-page":"1243","article-title":"Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomy","volume":"5","author":"Demill","year":"2011","journal-title":"Clin Ophthalmol"},{"key":"R2-20251008","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/0002-9394(89)90860-X","article-title":"Refractive complications of cataract surgery after radial keratotomy","volume":"108","author":"Koch","year":"1989","journal-title":"Am J Ophthalmol"},{"key":"R3-20251008","doi-asserted-by":"crossref","first-page":"490","DOI":"10.3928\/1081-597X-19951101-17","article-title":"Intraocular lens power calculation for eyes after refractive keratotomy","volume":"11","author":"Hoffer","year":"1995","journal-title":"J Refract Surg"},{"key":"R4-20251008","first-page":"203","article-title":"Consultations in refractive surgery: IOL calculations following radial keratotomy surgery","volume":"5","author":"Jt","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"R5-20251008","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/S0161-6420(99)90153-7","article-title":"Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy","volume":"106","author":"Seitz","year":"1999","journal-title":"Ophthalmology"},{"key":"R6-20251008","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1001\/archopht.120.4.431","article-title":"Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia","volume":"120","author":"Odenthal","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"R7-20251008","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jcrs.2006.08.045","article-title":"No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis","volume":"33","author":"Shammas","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R8-20251008","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.3928\/1081597X-20091117-05","article-title":"Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery","volume":"25","author":"Arce","year":"2009","journal-title":"J Refract Surg"},{"key":"R9-20251008","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.jcrs.2012.09.019","article-title":"New algorithm for post-radial keratotomy intraocular lens power calculations based on rotating Scheimpflug camera data","volume":"39","author":"Potvin","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R10-20251008","doi-asserted-by":"crossref","first-page":"430","DOI":"10.3928\/1081597X-20090710-02","article-title":"An Intraocular lens power calculation formula based on optical coherence tomography: A pilot study","volume":"26","author":"Tang","year":"2010","journal-title":"J Refract Surg"},{"key":"R11-20251008","first-page":"34","article-title":"Optical coherence tomography\u2013based corneal power measurement and intraocular lens power calculation following laser vision correction (An American Ophthalmological Society Thesis)","volume":"111","author":"Huang","year":"2013","journal-title":"Trans Am Ophthalmol Soc"},{"key":"R12-20251008","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.jcrs.2011.11.025","article-title":"Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomography","volume":"38","author":"Tang","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R13-20251008","doi-asserted-by":"crossref","first-page":"2443","DOI":"10.1016\/j.ophtha.2015.08.037","article-title":"Comparison of newer IOL power calculation methods for post-corneal refractive surgery eyes","volume":"122","author":"Wang","year":"2015","journal-title":"Ophthalmology"},{"key":"R14-20251008","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","article-title":"Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia","volume":"42","author":"Abulafia","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R15-20251008","doi-asserted-by":"crossref","first-page":"832","DOI":"10.3928\/1081597X-20200930-02","article-title":"IOL Power calculation after radial keratotomy using the Haigis and Barrett True-K formulas","volume":"36","author":"Leite","year":"2020","journal-title":"J Refract Surg"},{"key":"R16-20251008","doi-asserted-by":"crossref","first-page":"OCT162","DOI":"10.1167\/iovs.15-18948","article-title":"Comparison of newer IOL power calculation methods for eyes with previous radial keratotomy","volume":"57","author":"Ma","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R17-20251008","article-title":"Assessing post-RK eyes","author":"Dell","year":"2010","journal-title":"J Cataract Refract Surg Today"},{"key":"R18-20251008","first-page":"176","volume":"3","year":"1996","journal-title":"Basic and clinical science course: Optics, refraction, and contact lenses"},{"key":"R20-20251008","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1016\/j.jcrs.2004.02.075","article-title":"Intraocular lens power calculation after incisional and thermal keratorefractive surgery","volume":"30","author":"Packer","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R21-20251008","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1016\/j.jcrs.2007.03.018","article-title":"Intraocular lens power calculation after radial keratotomy: estimating the refractive corneal power","volume":"33","author":"Awwad","year":"2007","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3417_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:42:16Z","timestamp":1786650136000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_3417_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,21]]},"references-count":20,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_3417_22","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,21]]},"assertion":[{"value":"2022-12-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}