{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:27:03Z","timestamp":1786739223417,"version":"build-2736575974"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the clinical performance and rotational stability after implantation of Eyecryl Toric monofocal IOL following cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria were implanted with Eyecryl Toric IOL. All implantations were done under balanced salt solution. A marker-less system Callisto Eye (Carl Zeiss Meditec, Germany) was used to guide the intra-operative alignment of the toric IOL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 50 eyes from 39 patients with mean age of 68.2 \u00b1 8.7 years were included in the study. At 12 months, 82% (41) eyes had cumulative UDVA of 20\/20 or better. Post-op SE refraction accuracy was within \u00b1 0.50 D for 94% (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 47) eyes and refractive cylinder accuracy was within \u22640.50 D in 98% (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 49) eyes. Average post-op rotation at 1 year was 4.06 \u00b1 2.15 degrees. Eighty-four percent of eyes were within 5 degrees and 16% were within 6-10 degrees of intended axis. Two eyes required IOL re-positioning due to significant rotation of the toric IOL (&gt;10 degrees), identified within the 1\n                      <jats:sup>st<\/jats:sup>\n                      week after surgery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Eyecryl toric IOL demonstrated the ability to achieve a significant reduction in astigmatism, improved UDVA outcomes, high levels of spectacle independence, low rates of intra-operative injector related complications and good rotational stability at 12 months post-op.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_3463_20","type":"journal-article","created":{"date-parts":[[2021,6,25]],"date-time":"2021-06-25T14:43:02Z","timestamp":1624632182000},"page":"1775-1780","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Clinical outcomes and rotational stability following implantation of Eyecryl toric intraocular lens \u2013 Results of a 12-months prospective study"],"prefix":"10.4103","volume":"69","author":[{"given":"Sheetal","family":"Brar","sequence":"first","affiliation":[{"name":"Cataract and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mamta Lakhana","family":"Shah","sequence":"additional","affiliation":[{"name":"Cataract and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Smith Snehal","family":"Sute","sequence":"additional","affiliation":[{"name":"Cataract and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Savio","family":"Pereira","sequence":"additional","affiliation":[{"name":"Cataract and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sri","family":"Ganesh","sequence":"additional","affiliation":[{"name":"Cataract and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,6,18]]},"reference":[{"key":"R1-20260523","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1007\/s10792-016-0327-z","article-title":"Prevalence of corneal astigmatism before cataract surgery in Indian population","volume":"37","author":"Prasher","year":"2017","journal-title":"Int Ophthalmol"},{"key":"R2-20260523","doi-asserted-by":"crossref","first-page":"149","DOI":"10.4103\/tjo.tjo_51_18","article-title":"Photorefractive keratectomy for correcting residual refractive error following cataract surgery with premium intraocular lens implantation","volume":"8","author":"Fan","year":"2018","journal-title":"Taiwan J Ophthalmol"},{"key":"R3-20260523","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1136\/bjophthalmol-2014-306587","article-title":"Comparative evaluation of aspheric toric intraocular lens implantation and limbal relaxing incisions in eyes with cataracts and \u22643 dioptres of astigmatism","volume":"100","author":"Lam","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R4-20260523","first-page":"CD012801","article-title":"Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification","volume":"12","author":"Lake","year":"2019","journal-title":"Cochrane Database Syst Rev"},{"key":"R5-20260523","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.ajo.2015.06.007","article-title":"Toric intraocular lens versus monofocal intraocular lens implantation and photorefractive keratectomy:A randomized controlled trial","volume":"160","author":"Nagpal","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R6-20260523","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.ajo.2017.06.007","article-title":"Toric intraocular lenses versus peripheral corneal relaxing incisions for astigmatism between 0.75 and 2.5 diopters during cataract surgery","volume":"180","author":"Nanavaty","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"R7-20260523","doi-asserted-by":"crossref","first-page":"2305","DOI":"10.2147\/OPTH.S233125","article-title":"Main complications of photorefractive keratectomy and their management","volume":"13","author":"Spadea","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"R8-20260523","doi-asserted-by":"crossref","first-page":"207","DOI":"10.3341\/kjo.2010.24.4.207","article-title":"Long-term efficacy and rotational stability of AcrySoftoric intraocular lens implantation in cataract surgery","volume":"24","author":"Kim","year":"2010","journal-title":"Korean J Ophthalmol"},{"key":"R9-20260523","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.ophtha.2014.06.027","article-title":"Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism","volume":"122","author":"Waltz","year":"2015","journal-title":"Ophthalmology"},{"key":"R10-20260523","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.jcrs.2008.04.041","article-title":"Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation","volume":"34","author":"Ma","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260523","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/S0886-3350(01)01035-5","article-title":"Toric intraocular lens implantation:100 consecutive cases","volume":"28","author":"Till","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R12-20260523","doi-asserted-by":"crossref","first-page":"375","DOI":"10.3928\/1081597X-20101005-01","article-title":"New axis-marking method for a toric intraocular lens:Mapping method","volume":"27","author":"Cha","year":"2011","journal-title":"J Refract Surg"},{"key":"R13-20260523","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.jcrs.2011.04.036","article-title":"Residual astigmatism produced by toric intraocular lens rotation","volume":"37","author":"Felipe","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R14-20260523","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1136\/bjophthalmol-2013-303094","article-title":"Astigmatism correction with toric intraocular lenses:Wavefront aberrometry and quality of life","volume":"97","author":"Mencucci","year":"2013","journal-title":"Br J Ophthalmol"},{"key":"R15-20260523","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","article-title":"Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery","volume":"43","author":"Webers","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R16-20260523","doi-asserted-by":"crossref","first-page":"e18582","DOI":"10.1097\/MD.0000000000018582","article-title":"Comparison between using INTEGRA and manual method in determining axis for intraocular lens implantation:Preliminary retrospective study","volume":"99","author":"Jaworski","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"R17-20260523","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1186\/s12886-019-1175-1","article-title":"Accuracy of toric intraocular lens implantation using automated vs manual marking","volume":"19","author":"Kim","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"R18-20260523","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.jcrs.2019.04.009","article-title":"Evaluation of an intraoperative toric intraocular lens alignment system using an image-guided system","volume":"45","author":"Varsits","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R19-20260523","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/S0161-6420(99)90504-3","article-title":"Postoperative intraocular lens rotation:A randomized comparison of plate and loop haptic implants","volume":"106","author":"Patel","year":"1999","journal-title":"Ophthalmology"},{"key":"R20-20260523","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jcrs.2010.08.049","article-title":"Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens","volume":"37","author":"Prinz","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R21-20260523","journal-title":"White papers, Eyecryl Toric Intraocular Lens, Biotech Vision Care"},{"key":"R22-20260523","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1186\/s12886-018-0758-6","article-title":"Comparison of two techniques for toric intraocular lens implantation:Hydro implantation versus ophthalmic viscosurgical devices","volume":"18","author":"Chen","year":"2018","journal-title":"BMC Ophthalmol"},{"key":"R23-20260523","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/S0886-3350(02)01843-6","article-title":"Early rotational stability of the longer Staar toric intraocular lens:Fifty consecutive cases","volume":"29","author":"Chang","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R24-20260523","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1016\/S0161-6420(00)00266-9","article-title":"Toric intraocular lenses for correcting astigmatism in 130 eyes","volume":"107","author":"Sun","year":"2000","journal-title":"Ophthalmology"},{"key":"R25-20260523","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.2147\/OPTH.S213132","article-title":"Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens","volume":"13","author":"Ribeiro","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"R26-20260523","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1038\/s41433-019-0521-0","article-title":"Early postoperative rotational stability and its related factors of a single-piece acrylic toric intraocular lens","volume":"34","author":"Li","year":"2020","journal-title":"Eye (Lond)"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_3463_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:26:57Z","timestamp":1786735617000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_3463_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,18]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_3463_20","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,18]]},"assertion":[{"value":"2020-11-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}