{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:34:48Z","timestamp":1787762088101,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,8]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the slit-lamp method and wavefront aberrometry method based on outcomes of toric realignment surgeries.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings:<\/jats:title>\n                    <jats:p>Tertiary care ophthalmic hospital.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Retrospective study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study included all eyes undergoing toric intraocular lens (TIOL) realignment surgery between January 2019 and December 2021 for which TIOL axis assessment by slit-lamp method and wavefront aberrometry method was available. Data were retrieved from electronic medical records, and we documented demographics, uncorrected visual acuity (UCVA), subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods on postoperative day 1 and day 14. In patients with misalignment, TIOL was realigned to the original position in group 1 (27 patients) and to an axis based on calculations provided by wavefront aberrometer in group 2 (25 patients). Post-realignment surgery, UCVA, subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods were assessed and analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      We analyzed 52 eyes and found that the mean preoperative misalignment with the slit-lamp method (44.9\u00b0 \u00b120.0\u00b0) and wavefront aberrometry (47.1\u00b0 \u00b119.5\u00b0) was similar. The corresponding degrees of misalignment post-TIOL repositioning surgeries were 5.2\u00b0 \u00b15.2\u00b0 (slit-lamp method) and 4.7\u00b0 \u00b15.1\u00b0 (wavefront aberrometry) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.615). Both groups showed significant improvement in median log of minimum angle of resolution (logMAR) UCVA and reduction in median refractive cylinder.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Slit-lamp method is as good as wavefront aberrometer method to assess TIOL axis. Toric realignment surgery is found to be safe, and realigning TIOL based on either slit-lamp method or wavefront aberrometer method equally improved UCVA and decreased residual refractive cylinder.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_37_23","type":"journal-article","created":{"date-parts":[[2023,8,1]],"date-time":"2023-08-01T03:33:05Z","timestamp":1690860785000},"page":"2978-2983","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Outcomes of toric intraocular lens realignment surgery done using slit-lamp method and wavefront aberrometry method"],"prefix":"10.4103","volume":"71","author":[{"given":"R Senthil","family":"Prasad","sequence":"first","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Sankarananthan","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aruna","family":"Pai","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikhil R","family":"Kamble","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Logesh","family":"Balakrishnan","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Chitradevi","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhu","family":"Shekhar","sequence":"additional","affiliation":[{"name":"Cataract and IOL Services, Aravind Eye Hospital and Post Graduate Institue of Ophthalmology, Madurai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,8,1]]},"reference":[{"key":"R1-20240828","doi-asserted-by":"crossref","first-page":"311","DOI":"10.2147\/OPTH.S178277","article-title":"Consensus on the management of astigmatism in cataract surgery","volume":"13","author":"Nu\u00f1ez","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"R2-20240828","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.4103\/ijo.IJO_810_17","article-title":"Optimizing outcomes with toric intraocular lenses","volume":"65","author":"Kaur","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R3-20240828","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s12886-018-0692-7","article-title":"Real-world refractive outcomes of toric intraocular lens implantation in a United Kingdom National Health Service setting","volume":"18","author":"Xue","year":"2018","journal-title":"BMC Ophthalmol?"},{"key":"R4-20240828","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1097\/j.jcrs.0000000000000415","article-title":"Comparison of surgical repositioning rates and outcomes for hydrophilic vs hydrophobic single-piece acrylic toric IOLs","volume":"47","author":"Haripriya","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R5-20240828","doi-asserted-by":"crossref","first-page":"57","DOI":"10.4103\/1858-540X.150996","article-title":"Determination of post-operative toric IOL alignment-Analyzed by two different methods:Slit-lamp versus Adobe Photoshop","volume":"6","author":"Farooqui","year":"2014","journal-title":"Sudan J Ophthalmol"},{"key":"R6-20240828","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.jcrs.2009.08.033","article-title":"Assessment of toric intraocular lens alignment by a refractive power\/corneal analyzer system and slitlamp observation","volume":"36","author":"Carey","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R7-20240828","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.clae.2010.12.009","article-title":"Clinical and experimental validation of a slit lamp modification to measure toric lens position","volume":"34","author":"Mukherjee","year":"2011","journal-title":"Contact Lens Anterior Eye"},{"key":"R8-20240828","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1016\/j.jcrs.2013.11.039","article-title":"Rotational performance and corneal astigmatism correction during cataract surgery:Aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal incision","volume":"40","author":"Maedel","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R9-20240828","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jcrs.2009.12.027","article-title":"Objective analysis of toric intraocular lens rotation and centration","volume":"36","author":"Wolffsohn","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R10-20240828","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ophtha.2017.07.004","article-title":"Incidence and outcomes of repositioning surgery to correct misalignment of toric intraocular lenses","volume":"125","author":"Oshika","year":"2018","journal-title":"Ophthalmology"},{"key":"R11-20240828","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.jcrs.2004.07.019","article-title":"Evaluating the eye's rotational stability during standard photography:Effect on determining the axial orientation of toric intraocular lenses","volume":"31","author":"Viestenz","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R12-20240828","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.jcrs.2007.01.030","article-title":"Rotational stability of a single-piece hydrophobic acrylic intraocular lens:New method for high-precision rotation control","volume":"33","author":"Weinand","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R13-20240828","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.jcrs.2008.10.057","article-title":"Software-based assessment of postoperative rotation of toric intraocular lens","volume":"35","author":"Shah","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R14-20240828","doi-asserted-by":"crossref","first-page":"820","DOI":"10.3928\/1081597X-20141117-01","article-title":"Software-based evaluation of toric IOL orientation in a multicenter clinical study","volume":"30","author":"Kasthurirangan","year":"2014","journal-title":"J Refract Surg"},{"key":"R15-20240828","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1016\/j.jcrs.2017.05.025","article-title":"Evaluation of postoperative toric intraocular lens alignment with anterior segment optical coherence tomography","volume":"43","author":"Lucisano","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R16-20240828","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s10384-011-0097-0","article-title":"Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomography","volume":"56","author":"Watanabe","year":"2012","journal-title":"Jpn J Ophthalmol"},{"key":"R17-20240828","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1016\/j.ophtha.2018.02.012","article-title":"Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes","volume":"125","author":"Lee","year":"2018","journal-title":"Ophthalmology"},{"key":"R18-20240828","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1016\/j.ophtha.2010.07.033","article-title":"The AcrySof toric intraocular lens in subjects with cataracts and corneal astigmatism","volume":"117","author":"Holland","year":"2010","journal-title":"Ophthalmology"},{"key":"R19-20240828","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.jcrs.2011.04.036","article-title":"Residual astigmatism produced by toric intraocular lens rotation","volume":"37","author":"Felipe","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R20-20240828","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1177\/1120672119834469","article-title":"Comparison of incidence of repositioning surgery to correct misalignment with three toric intraocular lenses","volume":"30","author":"Oshika","year":"2020","journal-title":"Eur J Ophthalmol"},{"key":"R21-20240828","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.jcrs.2014.01.044","article-title":"Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism","volume":"40","author":"Miyake","year":"2014","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_37_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:16:43Z","timestamp":1787761003000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/IJO.IJO_37_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8]]},"references-count":21,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_37_23","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8]]},"assertion":[{"value":"2023-01-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-05-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}