{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:32:56Z","timestamp":1787772776101,"version":"build-2784847793"},"reference-count":48,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>\n                      To determine the significance of any association between either change in angle kappa (K\u00b0) or the rectilinear displacement (\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      , mm) of the first Purkinje image relative to the pupil center and unexpected changes in astigmatism after phacoemulsification.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Orbscan II (Bausch and Lomb) measurements were taken at 1, 2, and 3 months after unremarkable phacoemulsification in patients implanted with spherical (group 1, SA60AT, Alcon) or aspheric (group 2, SN60WF, Alcon) nontoric IOLs. The outputs were used to calculate\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      . Astigmatism, measured by autorefractometry and subjective refraction, was subjected to vector analysis (polar and cartesian formats) to determine the actual change induced over the periods 1\u20132 and 2\u20133 months postop.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Chief findings were that the mean (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      , \u00b1SD, 95%CI) values for\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      over each period were as follows: Group 1, 0.407 (38, \u00b10.340, 0.299\u20130.521), 0.315 (23, \u00b10.184, 0.335\u20130.485); Group 2, 0.442 (45, \u00b10.423, 0.308\u20130.577), 0.372 (26, \u00b10.244, 0.335\u20130.485). Differences between groups were not significant. There was a significant linear relationship between (A) the change in K (\u0394K = value at 1 month-value at 2 months) and K at 1 month (\n                      <jats:italic toggle=\"yes\">x<\/jats:italic>\n                      ), where \u0394K =0.668-3.794X (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.812,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 38,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = &lt;0.001) in group 1 and \u0394K = 0.263\n                      <jats:italic toggle=\"yes\">x<\/jats:italic>\n                      -1.462 (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.494,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 45,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002) in group 2, (B)\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      and the J\n                      <jats:sub>45<\/jats:sub>\n                      vector describing the actual change in astigmatism between 1 and 2 months in group 2, where J\n                      <jats:sub>45<\/jats:sub>\n                      (by autorefractometry) =0.287\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      -0.160 (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.487,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 38,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001) and J\n                      <jats:sub>45<\/jats:sub>\n                      (by subjective refraction) =0.281\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      -0.102 (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.490,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 38,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.002), and (C) J\n                      <jats:sub>45<\/jats:sub>\n                      and \u0394K between 2 and 3 months in group 2, where J\n                      <jats:sub>45<\/jats:sub>\n                      (by subjective refraction) =0.086\u0394K-0.063 (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.378,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 26,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.020).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      Changes in the location of the first Purkinje image relative to the pupil center after phacoemulsification contributes to changes in refractive astigmatism. However, the relationship between the induced change in astigmatism resulting from a change in\n                      <jats:italic toggle=\"yes\">L<\/jats:italic>\n                      is not straightforward.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ijo.ijo_572_21","type":"journal-article","created":{"date-parts":[[2021,11,30]],"date-time":"2021-11-30T06:54:59Z","timestamp":1638255299000},"page":"3503-3510","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["The relationship between angle kappa and astigmatism after phacoemulsification with implanting of spherical and aspheric intraocular lens"],"prefix":"10.4103","volume":"69","author":[{"given":"Larysa","family":"Tutchenko","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudi","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Specialty Eye Hospital Svjetlost, Zagreb, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mykhailo","family":"Skovron","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olha","family":"Horak","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oleksiy","family":"Voytsekhivskyy","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,11,26]]},"reference":[{"key":"B2-20240828","doi-asserted-by":"crossref","first-page":"456","DOI":"10.3928\/1081-597X-20070501-06","article-title":"Measurement of angle kappa with synoptophore and Orbscan II in a normal population","volume":"23","author":"Basmak","year":"2007","journal-title":"J Refract Surg"},{"key":"B3-20240828","doi-asserted-by":"crossref","first-page":"e17873","DOI":"10.5812\/ircmj.17873","article-title":"Angle Kappa measurements:Normal values in healthy Iranian population obtained with the Orbscan II","volume":"17","author":"Gharaee","year":"2014","journal-title":"Iran Red Crescent Med J"},{"key":"B4-20240828","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1097\/ICU.0b013e3283543c41","article-title":"Measurement of angle kappa and centration in refractive surgery","volume":"23","author":"Park","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"B5-20240828","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s10792-013-9775-x","article-title":"Angle kappa changes after photorefractive keratectomy for myopia","volume":"34","author":"Zarei-Ghanavati","year":"2014","journal-title":"Int Ophthalmol"},{"key":"B6-20240828","first-page":"193","article-title":"Use of angle kappa in myopic photorefractive keratectomy","volume":"9","author":"Khakshoor","year":"2015","journal-title":"Clin Ophthalmol"},{"key":"B7-20240828","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s40662-015-0014-6","article-title":"Centration axis in refractive surgery","volume":"2","author":"Mosquera","year":"2015","journal-title":"Eye Vis (Lond)"},{"key":"B8-20240828","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.jcrs.2015.09.030","article-title":"Comparison of refractive and visual outcomes with centration points 80% and 100% from pupil center toward the coaxially sighted corneal light reflex","volume":"42","author":"Chang","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"B9-20240828","doi-asserted-by":"crossref","first-page":"141","DOI":"10.5301\/ejo.5000835","article-title":"Laser in situ keratomileusis for high hyperopia with corneal vertex centration and asymmetric offset","volume":"27","author":"de Ortueta","year":"2017","journal-title":"Eur J Ophthalmol"},{"key":"B10-20240828","doi-asserted-by":"crossref","first-page":"B103","DOI":"10.1364\/JOSAA.36.00B103","article-title":"Optical quality comparison between laser ablated myopic eyes with centration on coaxially sighted corneal light reflex and on entrance pupil center","volume":"36","author":"Liu","year":"2019","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"B11-20240828","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1097\/ICO.0000000000002274","article-title":"The effect of intraoperative angle kappa adjustment on higher-order aberrations before and after small incision lenticule extraction","volume":"39","author":"Shao","year":"2020","journal-title":"Cornea"},{"key":"B12-20240828","doi-asserted-by":"crossref","first-page":"3555","DOI":"10.1007\/s10792-020-01506-1","article-title":"Clinical outcomes of corneal refractive surgery comparing centration on the corneal vertex with the pupil center:A meta-analysis","volume":"40","author":"Zhang","year":"2020","journal-title":"Int Ophthalmol"},{"key":"B13-20240828","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1038\/eye.2011.150","article-title":"Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation","volume":"25","author":"Prakash","year":"2011","journal-title":"Eye (Lond)"},{"key":"B14-20240828","doi-asserted-by":"crossref","first-page":"151","DOI":"10.4103\/0974-620X.122268","article-title":"Angle Kappa and its importance in refractive surgery","volume":"6","author":"Moshirfar","year":"2013","journal-title":"Oman J Ophthalmol"},{"key":"B15-20240828","doi-asserted-by":"crossref","first-page":"e123","DOI":"10.1111\/aos.12521","article-title":"The importance of angle kappa evaluation for implantation of diffractive multifocal intra-ocular lenses using pseudophakic eye model","volume":"93","author":"Karhanov\u00e1","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"B16-20240828","first-page":"241","article-title":"Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation","volume":"10","author":"Tchah","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"B17-20240828","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.jcrs.2018.05.026","article-title":"Role of angle k in visual quality in patients with a trifocal diffractive intraocular lens","volume":"44","author":"Qi","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"B18-20240828","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1007\/s00417-020-04761-1","article-title":"Factors for good near and distance visual outcomes of multifocal intraocular lens with inferior segmental near add","volume":"258","author":"Kim","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"B19-20240828","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.optom.2020.07.004","article-title":"Influence of angle Kappa on the optimal intraocular orientation of asymmetric multifocal intraocular lenses","volume":"14","author":"Bonaque-Gonz\u00e1lez","year":"2021","journal-title":"J Optom"},{"key":"B20-20240828","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1016\/j.jcrs.2017.05.028","article-title":"Variability in angle k and its influence on higher-order aberrations in pseudophakic eyes","volume":"43","author":"Harrer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"B21-20240828","doi-asserted-by":"crossref","first-page":"70","DOI":"10.3341\/kjo.2018.0085","article-title":"Analysis of positional relationships of various centers in cataract surgery","volume":"33","author":"Song","year":"2019","journal-title":"Korean J Ophthalmol"},{"key":"B22-20240828","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/j.jcrs.0000000000000063","article-title":"Changes in angle kappa and angle alpha before and after cataract surgery","volume":"46","author":"Wang","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"B23-20240828","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1111\/opo.12719","article-title":"When is refraction stable following routine cataract surgery?A systematic review and meta-analysis","volume":"40","author":"Charlesworth","year":"2020","journal-title":"Ophthalmic Physiol Opt"},{"key":"B24-20240828","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1097\/00006324-198410000-00001","article-title":"Meridional variations of corneal shape","volume":"61","author":"Kiely","year":"1984","journal-title":"Am J Optom Physiol Opt"},{"key":"B25-20240828","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1111\/j.1755-3768.1985.tb01579.x","article-title":"The central-peripheral radius of the normal corneal curvature. A photokeratoscopic study","volume":"63","author":"Edmund","year":"1985","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"B26-20240828","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1111\/j.1475-1313.1986.tb00699.x","article-title":"Corneal topography:A clinical model","volume":"6","author":"Guillon","year":"1986","journal-title":"Ophthalmic Physiol Opt"},{"key":"B27-20240828","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1088\/0959-5309\/55\/5\/302","article-title":"Ray tracing through non-spherical surfaces","volume":"55","author":"Baker","year":"1943","journal-title":"Proc Phys Soc"},{"key":"B28-20240828","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1097\/00006324-198212000-00011","article-title":"Unwanted astigmatism in lenses with a concentric variation in sagittal power","volume":"59","author":"Charman","year":"1982","journal-title":"Am J Optom Physiol Opt"},{"key":"B29-20240828","doi-asserted-by":"crossref","first-page":"374","DOI":"10.3928\/1081-597X-20070401-10","article-title":"Theoretical comparison of aberration-correcting customized and aspheric intraocular lenses","volume":"23","author":"Piers","year":"2007","journal-title":"J Refract Surg"},{"key":"B30-20240828","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1016\/j.jcrs.2013.01.037","article-title":"Visual performance of 2 aspheric toric intraocular lenses:Comparative study","volume":"39","author":"Scialdone","year":"2013","journal-title":"J Cataract Refract Surg"},{"issue":"Suppl 11","key":"B31-20240828","first-page":"S102","article-title":"Comparison of visual outcomes for aspheric and spherical toric intraocular lens implantation in cataract patients with pre-existing corneal astigmatism:A randomized control trial","volume":"97","author":"Naripthaphan","year":"2014","journal-title":"J Med Assoc Thai"},{"key":"B32-20240828","first-page":"270","article-title":"[Comparative study of the tilt, decentration and higher-order aberrations (HOA) of single-piece and 3-piece tecnis aspheric intraocular lenses]","volume":"51","author":"Yu","year":"2015","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"B33-20240828","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1364\/JOSA.50.000769","article-title":"Effects of involuntary eye movements on visual acuity","volume":"50","author":"Keesey","year":"1960","journal-title":"J Opt Soc Am"},{"key":"B35-20240828","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00417-013-2509-y","article-title":"Measurement of angle Kappa with Orbscan II and Galilei G4:Effect of accommodation","volume":"252","author":"Dom\u00ednguez-Vicent","year":"2014","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"B36-20240828","doi-asserted-by":"crossref","first-page":"966","DOI":"10.3928\/1081597X-20100114-06","article-title":"Distribution of angle kappa measurements with Orbscan II in a population-based survey","volume":"26","author":"Hashemi","year":"2010","journal-title":"J Refract Surg"},{"key":"B37-20240828","first-page":"7018937","article-title":"Influence of Angle k and higher-order aberrations on visual quality employing two diffractive trifocal IOLs","author":"Velasco-Barona","year":"2019","journal-title":"J Ophthalmol"},{"key":"B38-20240828","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0886-3350(00)00798-7","article-title":"Astigmatism analysis by the Alpins method","volume":"27","author":"Alpins","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"B39-20240828","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","article-title":"Power vectors:An application of Fourier analysis to the description and statistical analysis of refractive error","volume":"74","author":"Thibos","year":"1997","journal-title":"Optom Vis Sci"},{"key":"B40-20240828","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.1016\/j.jcrs.2010.05.031","article-title":"Improving the prediction accuracy of the SRK\/T formula:The T2 formula","volume":"36","author":"Sheard","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"B41-20240828","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ajo.2017.10.020","article-title":"Development and clinical accuracy of a new intraocular lens power formula (VRF) compared to other formulas","volume":"185","author":"Voytsekhivskyy","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"B42-20240828","doi-asserted-by":"crossref","first-page":"421","DOI":"10.3341\/kjo.2013.27.6.421","article-title":"The correlation between angle kappa and ocular biometry in Koreans","volume":"27","author":"Choi","year":"2013","journal-title":"Korean J Ophthalmol"},{"key":"B43-20240828","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1097\/ICO.0000000000001491","article-title":"Epidemiology of persistent dry eye-like symptoms after cataract surgery","volume":"37","author":"Iglesias","year":"2018","journal-title":"Cornea"},{"key":"B44-20240828","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.sjopt.2018.10.009","article-title":"Incidence and pattern of dry eye after cataract surgery","volume":"33","author":"Ishrat","year":"2019","journal-title":"Saudi J Ophthalmol"},{"key":"B45-20240828","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/S0161-6420(99)00513-8","article-title":"Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency","volume":"106","author":"Liu","year":"1999","journal-title":"Ophthalmology"},{"key":"B46-20240828","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1167\/iovs.17-23500","article-title":"Irregular astigmatism and higher-order aberrations in eyes with dry eye disease","volume":"59","author":"Koh","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"B47-20240828","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1016\/S0161-6420(02)01136-3","article-title":"Effect of artificial tears on corneal surface regularity, contrast sensitivity, and glare disability in dry eyes","volume":"109","author":"Huang","year":"2002","journal-title":"Ophthalmology"},{"key":"B48-20240828","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.clae.2020.01.002","article-title":"The impact of exposure on the magnitude of astigmatism formed within the precorneal tear film over the central optical zone of the cornea in ocular surface disease","volume":"43","author":"Mrukwa Kominek","year":"2020","journal-title":"Cont Lens Anterior Eye"},{"key":"B49-20240828","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1111\/j.1475-1313.2005.00335.x","article-title":"Impact of decentration of astigmatic intra-ocular lenses on the residual refraction after cataract surgery","volume":"25","author":"Langenbucher","year":"2005","journal-title":"Ophthalmic Physiol Opt"},{"key":"B50-20240828","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.jcrs.2018.04.035","article-title":"Astigmatism induced by intraocular lens tilt evaluated via ray tracing","volume":"44","author":"Weikert","year":"2018","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_572_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:12:13Z","timestamp":1787771533000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ijo.IJO_572_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,26]]},"references-count":48,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/ijo.ijo_572_21","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,26]]},"assertion":[{"value":"2021-03-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-06-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}